25,193 research outputs found
Picture This: The Art and Business of Children's Books
The FIT Library presented "Love Your Library -- Picture This: The Art and Business of Children's Books" on Wednesday, Dec. 7th, 2016. William Low (FIT prof., painter, illustrator), Liz Starin (FIT alum and children's book illustrator) and Colleen AF Venable (author and Art Director for Workman Publishing) discussed their background, inspiration, technique, and tricks of the trade. Moderated by Leslie Preston
Data for: The effect of driver improvement interventions on crash involvement; has it been under-estimated?
Crash data for bus drivers by year and by culpability for crashes from Uppsala, Sweden. The culpable crashes are a subset of All crashes. This file is a subset from a database which has been used in papers likeaf Wåhlberg, A. E. (2002). Characteristics of low speed accidents with buses in public transport. Accident Analysis and Prevention, 34, 637-647.af Wåhlberg, A. E. (2008). The relation of non-culpable traffic incidents to bus drivers' celeration behavior. Journal of Safety Research, 39, 41-46
Detektion af Rygmarvslæsioner ved Multipel Sklerose. Sammenligning af Magnetisk Resonans Vægtninger
Adskillige typer for magnetisk resonans billedvægtninger er anbefalet til den bedst mulige fremstilling af multipel sklerose læsioner i rygmarven. Den diagnostiske virkningsfuldhed varierer mellem dem, grundet forskelle i kontrast forhold. Short-tau inversion-recovery (STIR) har god kontrast, men har historisk set syntes at mangle specificitet grundet billedartefakter og støj. Phase-Sensitive Inversion-recovery (PSIR) har vist god potential for bedre kontrast på 3 tesla scannere, men er ikke undersøgt på 1.5 tesla. Højere opløsning på scanninger, særligt tre-dimensionelle scanninger kan muligvis føre til opdagelsen af flere læsioner. Et studie blev gennemført for at undersøg de relative diagnostisk virkningsfuldhed på 1.5 teslaer, ved scanning af hele rygmarven for fire vægtninger.
Følgende sekvensvægtninger blev inkluderet i studiet: T2, PSIR, to-dimensionel STIR (2D-STIR) og tre-dimensionel STIR (3D-STIR). Hver vægtning blev scannet over to anatomiske områder – den cervikale og thorakale rygmarv. Scantider på cirka fire minutter, samt anatomisk dækning af billeder var ens for alle vægtninger. Opløsning variererede mellem vægtningerne. To radiologer, en på overlæge niveau og en på afdelingsniveau, adskilleligt evalueret på hver vægtninger, hver for sig. Opdagelse af læsioner blev noteret efter højde-position i columna vertebralis og subjektive vurderinger af artefakter og støj blev også indsamlet. Kappa værdier for enighed blev beregnet mellem radiologerne for hver vægtning. Efterfølgende samledes radiologerne til et konsensus review af alle patienter med alle vægtninger, samt axiale rekonstruktioner af 3D-STIR sekvenserne. Denne referens standard anvendtes til beregning af sensitivitet, og positiv prædiktiv værdi (PPV). Kontrast-til-støj forhold (CNR) målinger udførtes på læsioner angivet på referens standarden, ved brug af regions-of-interest, som var ens i størrelse og placering mellem vægtningerne.
2D-STIR ydede den højeste sensitivitet og opdagede flere læsioner end alle andre vægtninger, dog kan der være tale om billed-baseret selektions-bias, samt den ikke-perfekte referens standard. Forskelle i antal opdagede læsioner var statistisk signifikant for begge radiologer på cervikale scanninger og for en radiolog på thorakale. 2D-STIR ydede også en signifikant bedre CNR end alle andre vægtninger. PPV og enighed for denne sekvenstype var høje og sammenlignelig med T2-vægtningen. Diagnosticerbarheden blev ikke forstyrret af artefakter eller støj i større grad på 2D-STIR end på T2. PSIR var den mindst sensitive vægtning, trods at CNR var bedre end på T2. 3D-STIR tilføjet flere læsioner end T2 eller PSIR, når samlet med 2D-STIR fund. Disse ekstra læsioner var mindre i størrelse end den overordnet gennemsnit. Dog var 3D-STIR svært påvirket af støj og muligvis også samtidig-felts artefakter. PPV og enighed var lavest for 3D-STIR, .
2D-STIR er ikke længere mere påvirkelig overfor artefakter end T2 og har god PPV samt enighed mellem radiologer. Denne sekvens er måske nu pålidelig nok til at blive anvendt alene. PSIR havde betydeligt lav sensitivitet, særligt på thorakale scanninger og CNR var signifikant værre end på 2D-STIR. 3D-STIR var slemt påvirket af støj og billedartefakter, men kan muligvis tjene godt som anden sekvens ved cervikale scanninger, hvis undersøgelsestider tillader. T2 er også et pålideligt valg som anden sekvens og denne er lige anvendelig til thorakale såvel cervikale scanning
Isrogrogidda Falka Af-soomaaliga: Aragti ku aadan Midaynta Qoraalkiisa
Qoraagu wuxuu diraasad ku sameeyey sidii loo midayn lahaa af Soomaaliga qoraaal ahaan loo adeegsada. Gaar ahaan wuxuu diiradda saarayaa sidii loo midayn lahaa qaababka isrogrogga falalka oo haatan loo adeegsado siyaabo aan midaysanayn.In questo articolo, l'autore analizza e avanza una proposta relativamente alla standardizzazione del somalo scritto, in particolar modo delle forme di coniugazione dei verbi somali che attualmente non sono scritte in modo omogenea.In this article, the author analyzes and provides a proposal about the standardization of written Somali, in particular relating to verb conjugation forms whose orthography still differs today.Cabdirashid M. Ismaaciil, Cabdalla C. Mansuur, Saynab A. Sharci (eds.
Coastal Research and its Economic Justification
Proper and thorough planning of coastal engineering projects is discussed and the economie justification of research work indicated. Examples are given concerning navigational problems, coastal protection problems, and harbor sediment problems.KWP-collectio
Population prevalence, incidence, and predictors of atrial fibrillation in the Renfrew/Paisley study
<b>OBJECTIVES</b> Though atrial fibrillation (AF) is an important cause of cardiovascular morbidity, there are few large epidemiological studies of its prevalence, incidence, and risk factors. The epidemiological features of AF are described in one of the largest population cohorts ever studied.
<b>METHODS</b> The prevalence and incidence of AF were studied in the Renfrew/Paisley population cohort of 15 406 men and women aged 45-64 years living in the west of Scotland. This cohort was initially screened between 1972 and 1976 and again between 1977 and 1979. Incident hospitalisations with AF in the 20 year period following initial screening were also studied.
<b>RESULTS</b> The population prevalence of AF in this cohort was 6.5 cases/1000 examinations. Prevalence was higher in men and older subjects. In those who were rescreened, the four year incidence of AF was 0.54 cases/1000 person years. Radiological cardiomegaly was the most powerful predictor of new AF (adjusted odds ratio 14.0). During 20 year follow up, 3.5% of this cohort was discharged from hospital with a diagnosis of AF; the rate of incident hospitalisation for AF was 1.9 cases/1000 person years. Radiological cardiomegaly (adjusted odds ratio 1.46) and systolic blood pressure (adjusted odds ratio 2.1 for ≥ 169 mm Hg) were independent predictors of this outcome.
<b>CONCLUSIONS</b> Data from one of the largest epidemiological studies ever undertaken confirm that AF has a large population prevalence and incidence, even in middle aged people. More important, it was shown that the long term incidence of hospitalisation related to AF is high and that two simple clinical measurements are highly predictive of incident AF. These findings have important implications for the prevention of AF
Midaynta iyo Horumarinta Af-soomaaliga
Qoraagu wuxuu maqaalkan ku falanqaynayaa arrimo ku saabsan midaynta af Soomaaliga qoran, oo dadka qaarkood ay ku doodaan in ay dhibaato ka taagantahay, iyagoo u aanaynaya kala duwanaanta lahjadaha Soomaaliyeed iyo farta af Soomaaliga oo aan xasillayn. Qoraha oo soo bandhigayaa in arrimahaasu aanu sax ahayn, wuxuuna muujinayaa caqabadaha dhabta ah ee hortaagan houmarinta af Soomaaliga: afku wuxuu la'yahay dawlad si rasmi ah u adeegsato, weerar ba'anna waxaa ku haya af Ingiriisiga, xagga ereyadana nabaadguur xooggan ayaa ku dhacaya, gaar ahaan ereyada la xiriira dhaqanka Soomaaliyeed.L'autore, in questo articolo, analizzando la questione della lingua somala scritta, cerca di illustrare che la situazione del somalo standard non è cosi problematica come a detta di alcuni somali, specialmente, nell'ortografia e nella differenza tra i dialetti, ma il problema somalo è bensì riscontrabile in altri fattori: la mancanza di un stato che continui ad adottare il somalo come lingua ufficiale, l'estinzione di tantissimi vocaboli in disuso, nonché la forte influenza dalla lingua inglese.The author in this article, in analysing the written somali language, wants to show the somali standard situation is not so bad, like some Somalis say, especially in orthography and in vernaculars difference. In spite of, the somali language problem is recognisable in some others factors: lack of state that usually chooses somali language as official language, extinction of many terms in disuse and also the strong influence of English.Cabdirashid M. Ismaaciil, Cabdalla C. Mansuur, Saynab A. Sharci (eds.
Demographic characteristics and performance on the administered tests for the Low-AF and High-AF performers.
Demographic characteristics and performance on the administered tests for the Low-AF and High-AF performers.</p
Detektion af Rygmarvslæsioner ved Multipel Sklerose. Sammenligning af Magnetisk Resonans Vægtninger
Adskillige typer for magnetisk resonans billedvægtninger er anbefalet til den bedst mulige fremstilling af multipel sklerose læsioner i rygmarven. Den diagnostiske virkningsfuldhed varierer mellem dem, grundet forskelle i kontrast forhold. Short-tau inversion-recovery (STIR) har god kontrast, men har historisk set syntes at mangle specificitet grundet billedartefakter og støj. Phase-Sensitive Inversion-recovery (PSIR) har vist god potential for bedre kontrast på 3 tesla scannere, men er ikke undersøgt på 1.5 tesla. Højere opløsning på scanninger, særligt tre-dimensionelle scanninger kan muligvis føre til opdagelsen af flere læsioner. Et studie blev gennemført for at undersøg de relative diagnostisk virkningsfuldhed på 1.5 teslaer, ved scanning af hele rygmarven for fire vægtninger.
Følgende sekvensvægtninger blev inkluderet i studiet: T2, PSIR, to-dimensionel STIR (2D-STIR) og tre-dimensionel STIR (3D-STIR). Hver vægtning blev scannet over to anatomiske områder – den cervikale og thorakale rygmarv. Scantider på cirka fire minutter, samt anatomisk dækning af billeder var ens for alle vægtninger. Opløsning variererede mellem vægtningerne. To radiologer, en på overlæge niveau og en på afdelingsniveau, adskilleligt evalueret på hver vægtninger, hver for sig. Opdagelse af læsioner blev noteret efter højde-position i columna vertebralis og subjektive vurderinger af artefakter og støj blev også indsamlet. Kappa værdier for enighed blev beregnet mellem radiologerne for hver vægtning. Efterfølgende samledes radiologerne til et konsensus review af alle patienter med alle vægtninger, samt axiale rekonstruktioner af 3D-STIR sekvenserne. Denne referens standard anvendtes til beregning af sensitivitet, og positiv prædiktiv værdi (PPV). Kontrast-til-støj forhold (CNR) målinger udførtes på læsioner angivet på referens standarden, ved brug af regions-of-interest, som var ens i størrelse og placering mellem vægtningerne.
2D-STIR ydede den højeste sensitivitet og opdagede flere læsioner end alle andre vægtninger, dog kan der være tale om billed-baseret selektions-bias, samt den ikke-perfekte referens standard. Forskelle i antal opdagede læsioner var statistisk signifikant for begge radiologer på cervikale scanninger og for en radiolog på thorakale. 2D-STIR ydede også en signifikant bedre CNR end alle andre vægtninger. PPV og enighed for denne sekvenstype var høje og sammenlignelig med T2-vægtningen. Diagnosticerbarheden blev ikke forstyrret af artefakter eller støj i større grad på 2D-STIR end på T2. PSIR var den mindst sensitive vægtning, trods at CNR var bedre end på T2. 3D-STIR tilføjet flere læsioner end T2 eller PSIR, når samlet med 2D-STIR fund. Disse ekstra læsioner var mindre i størrelse end den overordnet gennemsnit. Dog var 3D-STIR svært påvirket af støj og muligvis også samtidig-felts artefakter. PPV og enighed var lavest for 3D-STIR, .
2D-STIR er ikke længere mere påvirkelig overfor artefakter end T2 og har god PPV samt enighed mellem radiologer. Denne sekvens er måske nu pålidelig nok til at blive anvendt alene. PSIR havde betydeligt lav sensitivitet, særligt på thorakale scanninger og CNR var signifikant værre end på 2D-STIR. 3D-STIR var slemt påvirket af støj og billedartefakter, men kan muligvis tjene godt som anden sekvens ved cervikale scanninger, hvis undersøgelsestider tillader. T2 er også et pålideligt valg som anden sekvens og denne er lige anvendelig til thorakale såvel cervikale scanning.Various types of magnetic resonance image weightings are recommended for the detection of multiple sclerosis lesions in the spinal cord. There are varying levels of diagnostic efficacy between them, due to differences in contrast ratios. Short-tau inversion-recovery (STIR) has good contrast, but has historically been viewed as lacking specificity due to imaging artefacts and noise. Phase-sensitive inversion-recovery (PSIR) has shown potential for greater contrast at 3 teslas, but has not been investigated at 1.5 tesla. Higher resolution scans, particularly three-dimensional scans can possibly detect more lesions. A study was conducted in order to investigate relative diagnostic efficacies at 1.5 tesla for the whole spinal cord for four image-weightings.
The following sequence weightings were included in this study: T2, PSIR, two-dimensional short-tau inversion-recovery (2D-STIR) and three-dimensional short-tau inversion-recovery (3D-STIR). Each weighting was scanned over two areas of anatomy – the cervical and thoracic spinal cord. Scan times of roughly four minutes and area coverage were the same for all weightings. Resolutions were varied. Two radiologists, one of consultant level, one of departmental level, separately evaluated each sequence weighting alone. Detection of lesions was recorded by level in the spinal column, and subjective evaluations of artefacts and noise were also measured. Kappa values for agreement between radiologists were calculated for each weighting. Subsequently, both radiologists consensus-reviewed all patients with the use of all images available including axial reconstructions of the 3D-STIR acquisition. This reference standard was used to calculate sensitivities and positive-predictive-values (PPV). Contrast-to-noise measurements (CNR) were done for consensus confirmed lesions by the use of regions-of-interest, which were of identical size and position between weightings.
2D-STIR had the highest sensitivity and detected more lesions than all other sequences, though there may be issues with image-based selection bias and the imperfect reference standard. This difference was statistically significant for both radiologists on cervical coverage scans and for one radiologist on thoracic scans. 2D-STIR also had significantly greater CNR than all other sequences for both areas of coverage. PPV and agreement for this sequence were high and comparable with that of T2. Diagnosis was no more affected by artefacts and noise on 2D-STIR than T2. PSIR was the least sensitive sequence, despite having a slightly better CNR than T2. 3D-STIR added a greatest number of lesions when added to 2D-STIR findings, than PSIR or T2. These additional lesions were smaller in size than the overall average. But 3D-STIR was badly affected by noise and possibly concomitant field artefacts. PPV was lowest for 3D-STIR.
2D-STIR is no more affected by artefacts than T2 and has good PPV and agreement. This sequence is now perhaps good enough to be used alone. PSIR had poor sensitivity especially on thoracic scans and CNR was significantly worse than 2D-STIR. 3D-STIR was very badly affected by noise and imaging artefacts, but can perhaps serve as a good secondary sequence for cervical scanning if examination times allow. T2 is also a reliable choice as a secondary sequence and is just as useful for thoracic scanning as for cervical
Fra affald til genbrug:Evaluering af et udviklingsprojekt om uddannelse af renovationsarbejdere på tværs af landegrænser
Rapporten beskriver og evaluerer et større udviklingsprojekt på tværs af Øresund med henblik på at udvikle og afprøve en omfattende uddannelse for renovationsarbejdere, som udvikler deres faglige og personlige kompetencer fra indsamling af skrald til funktionen som medarbejdere i virksomheder, der står for bæredygtig affaldshåndtering henimod maksimalt genbru
- …
