169,704 research outputs found
EFFECTS OF SEMINAL PLASMA AND 3 EXTENDERS ON CANINE SEMEN STORED AT 4-DEGREES-C
Semen preservation and artificial insemination (Al) in the canine has become a common practice in veterinary medicine. Chilled dog semen is easy to handle, and several extenders can be used. The aim of this study was to compare the effects on canine spermatozoa of seminal plasma and 3 extenders commonly used for chilled semen preservation in clinical practice. The characteristics evaluated were sperm motility; velocity; plasma membrane status (assessed with a fluorescence staining technique and hypo-osmotic swelling test); acrosome morphology; semen pH; and semen osmolarity. These criteria were monitored daily in the ejaculates of ii dogs. The ejaculates were divided into 4 aliquots. Each aliquot was extended in autologous seminal plasma, egg-yolk Tris, egg-yolk milk or egg-yolk cream and preserved at 4 degrees C for 4 d. In 10 of 11 semen samples extended in autologous seminal plasma, motility had already decreased to 0% by Day 2, and the percentage of spermatozoa with intact membranes was lower than in the 3 extenders (P0.05). Egg-yolk Tris extender seems to be superior to the other extenders tested, to preserve dog semen at 4 degrees C, although differences were not significant for all the parameters
In vitro characteristics of canine spermatozoa subjected to two methods of cryopreservation
The in vitro Viability of canine spermatozoa was evaluated after freezing-thawing using the Andersen method, and the commercial CLONE method. These methods differ in the extenders used, number of dilution steps, and equilibration times as well as in both freezing and thawing techniques and rates. Insemination with semen frozen-thawed by either method gives high whelping rates in practice, implying that dog spermatozoa can retain their fertilizing ability after being subjected to widely different preservation methods. The in vitro viability of spermatozoa processed by these methods has not been previously evaluated in detail. Three ejaculates were collected from each of 5 fertile dogs. Each ejaculate was divided into 2 parts and frozen in medium straws according to the 2 methods. Two straws were thawed and examined from each freezing batch. Sperm motility was assessed in the undiluted semen, and in frozen-thawed semen immediately after thawing, and after storage for 3, 6 and 24 h at room temperature (Straw 1) or 1, 2 and 3 h at 37 degrees C (Straw 2, thermoresistance test). The integrity of the sperm plasma membrane was evaluated in undiluted, in equilibrated (diluted and chilled), and in frozen-thawed spermatozoa using fluorophore probes. The acrosome morphology of frozen-thawed spermatozoa was assessed using a commercial stain (Spermac(R)). Motility immediately after thawing was significantly higher with the CLONE method (75.3% [SD=4.0] for Straw 1 and 73.7% [SD=3.2] for Straw 2) than with the Andersen method (70.0% [SD=5.1] and 69.7% [SD=3.2]). Motility decreased during storage after thawing. Spermatozoa frozen-thawed using the CLONE method showed a significantly lower thermoresistance. The proportion of spermatozoa with intact plasma membrane was not affected by the equilibration procedure used with either method but was significantly decreased (P<0.001) after thawing with both methods. The percentage of spermatozoa exhibiting changes thought to represent different stages of acrosomal degradation, was 45.7% (SD=5.3) using the Andersen method and 44.1% (SD=9.2) using the CLONE method. Both cryopreservation methods thus resulted in high initial post-thaw sperm motility and membrane integrity but low thermoresistance, and under both methods a large proportion of sperm cells were undergoing acrosomal degradation. The methods differed significantly in terms of their effect on sperm motility but not on plasma membrane integrity or acrosomal morphology. (C) 1997 by Elsevier Science Inc
Effects of Equex STM paste on viability of frozen-thawed dog spermatozoa during in vitro incubation at 38 degrees C
In the canine, artificial insemination with cryopreserved semen generally yields lower pregnancy rates with vaginal deposition than with uterine deposition, one of the reasons being the shortened life span of frozen-thawed spermatozoa. The incubation of spermatozoa at body temperature partially mimics the situation in vivo, and evaluation of the kinetics of viability loss under these conditions can be used to measure the damage caused by freezing and thawing procedures. In this study, 2 aliquots were separated from split ejaculates collected from 7 dogs and were frozen by lowering the straws, in 3 steps, into an LN(2) tank after dilution with egg yolk Tris-citrate-glucose extender with or without the addition of 0.5% Equex STM paste. Motility and plasma membrane integrity (evaluated with the combined fluorescent probes 6-carboxyfluorescein diacetate and propidium iodide) were assessed immediately after thawing and over the next 3 h at 38 degrees C. The addition of Equex STM paste significantly increased the proportion of spermatozoa having an intact plasmalemma immediately after thawing compared with the control. It also increased the longevity of the thawed spermatozoa, prolonging the maintenance of both motility and plasma membrane integrity. (C) 1997 by Elsevier Science Inc
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Mitomycin C in highly myopic eyes - Author reply
Ophthalmology. 2005 Feb;112(2):208-18; discussion 219.
Mitomycin C modulation of corneal wound healing after photorefractive keratectomy in highly myopic eyes.
Gambato C, Ghirlando A, Moretto E, Busato F, Midena E.
SourceRefractive Surgery Service and Antimetabolite Therapy Research Unit, Department of Ophthalmology, University of Padova, Padova, Italy.
Abstract
PURPOSE: To evaluate the role of topical mitomycin C in corneal wound healing (CWH) after photorefractive keratectomy (PRK) in highly myopic eyes.
DESIGN: Prospective, double-masked, randomized clinical trial.
PARTICIPANTS: Seventy-two eyes of 36 patients affected by high (>7 diopters) myopia.
METHODS: In each patient, one eye was randomly assigned to PRK with intraoperative topical 0.02% mitomycin C application, and the fellow eye was treated with a placebo. Postoperatively, mitomycin C-treated eyes received artificial tears (3 times daily, tapered in 3 months), whereas the fellow eye was treated with fluorometholone sodium 2% and artificial tears (3 times daily, tapered in 3 months).
MAIN OUTCOME MEASURES: Uncorrected visual acuity (UCVA) and best-corrected visual acuity (BCVA), contrast sensitivity, manifest refraction, and biomicroscopy. Contrast sensitivity was determined using the Pelli-Robson chart. Corneal confocal microscopy documented CWH.
RESULTS: Mean follow-up was 18 months (range, 12-36). No side effects or toxic effects were documented. At 12-month follow-up examination, UCVAs (logarithm of the minimum angle of resolution) were 0.4+/-0.48 and 0.5+/-0.53 (P = .03) in mitomycin C-treated eyes and corticosteroid-treated eyes, respectively. At 1 year, corneal haze developed in 20% of corticosteroid-treated eyes, versus 0% of mitomycin C-treated eyes. At 12, 24, and 36 months, corneal confocal microscopy showed activated keratocytes and extracellular matrix significantly more evident in untreated eyes (Ps = 0.004, 0.024, and 0.046, respectively).
CONCLUSION: Topical intraoperative application of 0.02% mitomycin C can reduce haze formation in highly myopic eyes undergoing PRK.
Comment in
Ophthalmology. 2006 Feb;113(2):357; author reply 357-8
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
A Multi-Language Comparison of Influences on Author Verification using Character N-Grams
We create a new multi-language corpus for author verification based on Wikipedia talkpages, and evaluate the influence that differences in topic and time have on character n-gram author profiles. Topic alignment between two texts is found to increase author verification precision, and an authors writing style is found to change over time, but not more significantly after 3 years than after 1 year.Information ArchitectureWISElectrical Engineering, Mathematics and Computer Scienc
A 0.12mm<sup>2</sup> Wien-Bridge Temperature Sensor with 0.1°C (3σ) Inaccuracy from -40°C to 180°C
Resistor-based temperature sensors can achieve much higher resolution and energy efficiency than conventional BJT-based sensors [1], but they typically occupy more area (> 0.25 mm 2 ) and have lower operating temperatures (le 125 {circ} {C}) [2]-[4]. This work describes a 0.12mm 2 resistor-based sensor that uses a Wien-bridge (WB) filter to achieve 0.1 {circ} {C} (3 sigma) inaccuracy from - 40 {circ} {C} to 180 {circ} {C}. Compared to a state-of-the-art WB sensor [4], it occupies 6 × less area and achieves comparable relative accuracy over a 76% wider operating range. Session 10.3 Green Open Access added to TU Delft Institutional Repository ‘You share, we take care!’ – Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.Electronic InstrumentationMicroelectronic
A ±25A Versatile Shunt-Based Current Sensor with 10kHz Bandwidth and ±0.25% Gain Error from -40°C to 85°C Using 2-Current Calibration
Accurate current sensing is critical in many industrial applications, such as battery management and motor control. Precise shunt-based current sensors have been reported with gain errors of less than 1% over the industrial temperature range (-40°C to 85°C) [1]–[4]. However, since they are intended for coulomb counting, their bandwidth is limited to a few tens of Hz, making them unsuitable for battery impedance or motor-current sensing. This paper presents a current sensor with a wide (10kHz) bandwidth and a tunable temperature compensation scheme (TCS), which allows it to be flexibly used with different types of shunts while maintaining high accuracy. A low-cost room-temperature calibration scheme is proposed to optimize gain flatness over temperature by exploiting the shunt's self-heating at large currents. Over the industrial temperature range and a ±25A current range, it achieves state-of-the-art gain error (±0.25%) with both low-cost PCB and stable metal-alloy shunts.Green Open Access added to TU Delft Institutional Repository 'You share, we take care!' - Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.Electronic InstrumentationMicroelectronic
An Article About Albertus C. Van Raalte, Author Unknown, Except for Parts Taken from an Article by Anna C. Post
An article about Albertus C. Van Raalte, author unknown, except for parts taken from an article by Anna C. Post. The author knew first generation persons in the Holland settlement and therefore, the article has some value.https://digitalcommons.hope.edu/vrp_1890s/1012/thumbnail.jp
- …
