1,720,957 research outputs found
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
INVESTIGATION OF TERRAIN EFFECTS ON WHEELCHAIR PROPULSION AND VALIDITY OF A WHEELCHAIR PROPULSION MONITOR
This thesis is composed of two studies related to wheelchair propulsion biomechanics. The first study investigated the impact of cross-slope and surface roughness on wheelchair propulsion. Fifteen manual wheelchair users propelled across a five-meter platform which were set to level, 1°, or 2° cross slope, and attached with one of three surfaces including Teflon (slippery), wood (normal), and blind guide (rough). The study found main effects of both cross slope and surface roughness on stroke number and sum of work, and a main effect of cross slope on velocity. Subjects travelled slower, used more strokes, and expended more work with increasing cross slope. Subjects also used more strokes when propelling on the slippery and rough surfaces than on the level surface. They expended more work when propelling on the rough surface than on the level surface. When looking into bilateral propulsion parameters, we found that peak resultant force, peak wheel torque, and sum of work became significantly asymmetrical with the increase of cross slopes. Exposure to biomechanics loading can be reduced by avoiding slippery, rough, and cross slopes when possible. The second study consisted of a preliminary analysis on the validity of a wheelchair propulsion monitor (WPM) in estimating wheelchair propulsion biomechanics. The WPM integrates three devices including a wheel rotation datalogger, and an accelerometry-based device on the upper arm and underneath the wheelchair seat, respectively. Five wheelchair users were asked to push their own wheelchairs fitted with a SMARTWheel over level and sloped surfaces on two separate visits. The estimated stroke number and cadence by the WPM were consistent with the criterion measures by the SMARTWheel (ICC= 0.99 for stroke number, ICC=0.97 for cadence) with less than 5% absolute percentage errors for stroke number and 9% for cadence. The peak resultant force and wheel torque could be predicted to some extent by acceleration features on an individual subject basis. The study demonstrated the potential of the WPM in tracking wheelchair propulsion characteristics in the natural environment of wheelchair users
Recommended from our members
An End-to-End Concentric Tube Robot System Design for Medical Applications
Continuum robots have significant potential for impact in surgical applications, due totheir compliance and ability to safely traverse complex and constrained environments. One class of continuum robots, known as concentric tube robots (CTRs), show particular promise for minimally invasive surgery due to their miniature size (0.5-3mm) and inherent hollow channel for the passage of surgical tools.
Despite recent advancements in CTRs, several challenges related to design, manufacturing, and teleoperation must still be addressed to achieve successful clinical translation. Due to variations in anatomy among patients and variations in task requirements among procedures, it is often necessary to customize the design of these robots on a patient- or population-specific basis. However, the complex kinematics and large design space make the design problem challenging. Here we propose a generalized computational framework that efficiently optimizes the CTR design and motion plan for safe navigation through a patient’s anatomy. The framework is the first fully gradient-based method for CTR design optimization and motion planning, enabling an efficient and scalable solution for simultaneously optimizing continuous variables, even across multiple anatomies. However, uncertainties in the manufacturing process can lead to challenges in the transition from simulated designs to physical robots. To minimize this gap, we propose an end-to-end design and manufacturing workflow on top of the previously developed optimization framework for CTRs that considers the often-overlooked impact of manufacturing uncertainty, focusing on two primary sources — tube curvature and diameter. This comprehensive approach incorporates a two-step design optimization and an uncertainty-based selection of manufacturing tolerances. By integrating these uncertainties into the design process, we can effectively bridge the gap between simulation and real-world performance, which we demonstrate through a case study on micro-laryngeal surgery. In addition to the design and fabrication of the patient-side robot, another critical aspect of minimally invasive surgical robotic systems is the surgeon-side input device for teleoperation. Delivering effective haptic feedback to the surgeon remains an open research question. Here we introduce a haptic continuum robot (HCR) for multi-modal cutaneous feedback, capable of conveying skin stretch, slip, normal indentation, and vibration to the fingertips. This device is the first to explore the use of both the tip and body of the continuum robot for haptic feedback, and it has the potential to convey task-critical information during teleoperation tasks. In summary, this dissertation aims to address the challenges in end-to-end concentric tube robot system design, enhancing both patient- and surgeon-side systems to ultimately improve clinical outcomes
koamabayili/VECTRON-author-checklist: VECTRON author checklist
We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
Recommended from our members
Development of a Low-Cost System for Laparoscopic Skills Training
Technological advancements in video equipment and biocompatible materials has enabled improvements in complex surgery through small incisions. The mastery of these laparoscopic surgical techniques is now a requirement for surgeons, however, the necessary skills are not intuitive and require hundreds of practice hours. The current state of surgical education includes animate models, inanimate physical models, and computer-based simulations, the latter of which are limited by cost, accessibility, and a lack of engagement. We propose a novel low-cost training interface that mimics the laparoscopic surgical environment using customized instruments whose movement and control are used as inputs for video games. The system is significantly less expensive than commercial systems and allows users freedom to select and play any game, enabling a take-home system with potential for higher levels of engagement, as well as familiarity and expertise with ambidextrous laparoscopic hand motion. A preliminary study compared performance on FLS (Fundamentals of Laparoscopic Surgery) testing before and after training. For a precision cutting task, groups that trained on a standard simulator or on the new system with either a non-inverted or inverted hand-instrument mapping, showed statistically significant improvements, warranting further investigation of training with this new system
- …
