1,720,997 research outputs found
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
Flow boiling of R32 in a horizontal stainless steel tube with 6.00 mm ID. Experiments, assessment of correlations and comparison with refrigerant R410A
Refrigerant R32 is one option for the replacement of R410A in residential air conditioning and heat pump systems. This paper focus on the flow boiling characteristics of pure R32 in a single horizontal stainless steel tube with an internal diameter of 6.0 mm. A total of 437 experimental results are presented for twophase heat transfer coefficient and frictional pressure drop and the effect of the operating parameters in terms of mass flux (from 146 to 507 kg/m2 s), saturation temperature (from 24.6 to 40.6 °C) and imposed heat flux (from 2.4 to 41.2 kW/m2) is discussed. Several heat transfer coefficient and pressure drop data of R410A obtained in the same test section are also used for comparison purposes. Finally, predictions of the most quoted flow boiling heat transfer and frictional pressure drop methods are compared to experimental data to evaluate their agreement
Waste heat driven multi-ejector cooling systems: Optimization of design at partial load; seasonal performance and cost evaluation
In this paper, a seasonal performance analysis of a hybrid ejector cooling system is carried-out, by considering a multi-ejector pack as expansion device. A 20 kW ejector-based chiller was sized to obtain the optimal tradeoff between performance and investment costs. The seasonal performance of the proposed solution was then evaluated through a dynamic simulation able to obtain the performance of the designed chiller with variable ambient temperatures for three different reference climates. The optimized multi-ejector system required three or four ejectors for any reference climate and was able to enhance the system performance at partial load, with a significant increase (up to 107%) of the seasonal energy efficiency ratio. The proposed system was then compared to conventional cooling technologies supplied by electric energy (electrical chillers EHP) or low-grade heat sources (absorption chillers AHP) by considering the total costs for a lifetime of 20 years and electric energy-specific costs for domestic applications from 0.10 to 0.50 €/kWhel. The optimized multi-ejector cooling system presented a significant convenience with respect to both conventional technologies. For warmer climates and with high electricity costs, the minimum lifetime for the multi-ejector system to achieve the economic break-even point could be as low as 1.9 years
koamabayili/VECTRON-author-checklist: VECTRON author checklist
We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
Experimental data during flow boiling of refrigerants R448A and R452A
Refrigerators and heat pump systems represent a significant contribution to the global warming phenomenon, due to direct greenhouse gas emissions in case of leakages and plants dismantlement. For this reason, there is an increasing interest from the scientific community and the manufacturers towards low-GWP refrigerants. Among them, R448A and R452A are two attractive solutions for the next future as possible replacements of R404A. However, few data on two-phase heat transfer and pressure drop are currently available in open literature. This paper therefore presents flow boiling heat transfer and pressure drop experimental data of refrigerants R448A and R452A in a horizontal stainless-steel tube with an internal diameter of 6.0 mm. The effect of the operating parameters in terms of mass flux (from 150 to 600 kg m-2s-1), heat flux (from 10 to 40 kW m-2) and saturation temperature (from 25 to 55 °C) are presented and discussed
- …
