1,720,961 research outputs found
STUDY OF ORAL CAVITY LESIONS BY INFRARED SPECTROSCOPY
Fourier transform infrared (FTIR) microspectroscopy is considered a useful tool in the biomedical field, for analysing in situ and at cellular level, very small areas of tissues and cells, with minimal sample preparation and without the use of stains or probes. This spectroscopic technique has been successfully applied to analyse biological samples from patients affected by tumoral pathologies, with particular attention to oral cavity lesions. In this study, we describe the application of FTIR microspectroscopy to characterize and discriminate the most recurrent benign and malignant diseases of oral cavity compartment. Infrared maps were acquired on tissues affected by the following pathologies: squamous cell carcinoma, adenoid cystic carcinoma, polymorphous low-grade adenocarcinoma, squamous dysplasia, keratocystic odontogenic tumor, radicular cyst, residual cyst, unicystic ameloblastoma, and ameloblastic fibroma, together with healthy tissue samples (used as control group). The epithelial and connective components of all samples were distinguished and submitted to multivariate analysis. The results were in agreement with histological suggestions
VIBRATIONAL MAPPING OF SINONASAL LESIONS BY FOURIER TRANSFORM INFRARED IMAGING SPECTROSCOPY
Fourier transform infrared imaging (FTIRI) is a powerful tool for analyzing biochemical changes in
tumoral tissues. The head and neck region is characterized by a great variety of lesions, with different degrees
of malignancy, which are often difficult to diagnose. Schneiderian papillomas are sinonasal benign neoplasms
arising from the Schneiderian mucosa; they can evolve into malignant tumoral lesions (squamous cell carcinoma).
In addition, they can sometimes be confused with the more common inflammatory polyps. Therefore,
an early and definitive diagnosis of this pathology is mandatory. Progressing in our research on the study of oral
cavity lesions, 15 sections consisting of inflammatory sinonasal polyps, benign Schneiderian papillomas, and
sinonasal undifferentiated carcinomas were analyzed using FTIRI. To allow a rigorous description of these pathologies
and to gain objective diagnosis, the epithelial layer and the adjacent connective tissue of each section
were separately investigated by following a multivariate analysis approach. According to the nature of the lesion,
interesting modifications were detected in the average spectra of the different tissue components, above all in
the lipid and protein patterns. Specific band-area ratios acting as spectral markers of the different pathologies
were also highlighted. © 2015 Society of Photo-Optical Instrumentation Engineers (SPIE) [DOI: 10.1117/1.JBO.20.12.125003
Spectroscopic and Mechanical Properties of a New Generation of Bulk Fill Composites
Objectives: The aims of this study were to in vitro evaluate the degree of conversion and the microhardness properties of five bulk fill resin composites; in addition, the performance of two curing lamps, used for composites polymerization, was also analyzed. Materials and Methods: The following five resin-based bulk fill composites were tested: SureFil SDR®, Fill Up!TM, FiltekTM, SonicFillTM, and SonicFill2TM. Samples of 4 mm in thickness were prepared using Teflon molds filled in one increment and light-polymerized using two LED power units. Ten samples for each composite were cured using Elipar S10 and 10 using Demi Ultra. Additional samples of SonicFill2, (3 and 5 mm-thick) were also tested. The degree of conversion (DC) was determined by Raman spectroscopy, while the Vickers microhardness (VMH) was evaluated using a microhardness tester. The experimental evaluation was carried out on top and bottom sides, immediately after curing (t0), and, on bottom, after 24 h (t24). Two-ways analysis of variance was applied to evaluate DC and VMH-values. In all analyses, the level of significance was set at p < 0.05. Results: All bulk fill resin composites recorded satisfactory DCs on top and bottom sides. At t0, the top of SDR and SonicFill2 showed the highest DCs-values (85.56 ± 9.52 and 85.47 ± 1.90, respectively), when cured using Elipar S10; using Demi Ultra, SonicFill2 showed the highest DCs-values (90.53 ± 2.18). At t0, the highest DCs-values of bottom sides were recorded by SDR (84.64 ± 11.68), when cured using Elipar S10, and Filtek (81.52 ± 4.14), using Demi Ultra. On top sides, Demi Ultra lamp showed significant higher DCs compared to the Elipar S10 (p < 0.05). SonicFill2 reached suitable DCs also on bottom of 5 mm-thick samples. At t0, VMH-values ranged between 24.4 and 69.18 for Elipar S10, and between 26.5 and 67.3 for Demi Ultra. Using both lamps, the lowest VMH-values were shown by SDR, while the highest values by SonicFill2. At t24, all DC and VMH values significantly increased. Conclusions: Differences in DC and VMH among materials are suggested to be material and curing lamp dependent. Even at t0, the three high viscosity bulk composites showed higher VMH than the flowable or dual curing composites
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
koamabayili/VECTRON-author-checklist: VECTRON author checklist
We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
- …
