1,720,973 research outputs found

    Complete Remission of Unresectable Hepatocellular Carcinoma after Combined Sorafenib and Adjuvant Yttrium-90 Radioembolization

    No full text
    Sorafenib has improved the median overall survival of unresectable or otherwise untreatable hepatocellular carcinoma (HCC) of ∼3 months, compared to supportive cares. Complete response, although rare, has been reported. The authors reported herein a case of complete biochemical and radiological remission of advanced unresectable HCC with lymph node metastasis and tumoral portal vein thrombosis treated by 5 months therapy with sorafenib followed by adjuvant Yttrium-90 radioembolization. At 12 months follow-up, there is no evidence of HCC recurrenc

    Screening for Squamous Cell Anal Cancer in HIV Positive Patients: A Five-Year Experience

    No full text
    Aim: Potential screening modalities for early diagnosis of squamous cell anal cancer (SCC) in HIV patients include digital anorectal examination (DARE), anal Papanicolaou testing (Pap test), human papilloma virus (HPV) co-testing, and high-resolution anoscopy. The aim of this study was to demonstrate the results of a five-year screening program for SCC in HIV patients. Materials and Methods: We conducted a retrospective study on 204 HIV patients who underwent a screening program for SCC from October 2010 to January 2015. All patients were screened by DARE, anal Pap test, including HPV test and cytology, and high-resolution video-proctoscopy (HR-VPS) with and without acetic acid 3%. Depending on macroscopic appearance and biopsies, patients underwent observation or treatment. Median follow-up was 36 months. Results: Cytologic abnormalities (Cyt+) for high-risk HPV genotypes were recorded in 34% of patients. HR-VPS was positive in 59 patients (29%), of whom 13 patients (22%) were positive for warts; the rest have typical features of anal intraepithelial neoplasia (AIN). Sixteen (8%) patients had AIN (AIN I–III) and underwent wide local excision, ablation, or imiquimod. Absence of progression was recorded. Fourteen patients (7%) had SCC: eight (57%) with no evidence of recurrence, two (14%) had recurrence, and four (29%) died from metastatic disease. Conclusions: Our data demonstrated a successful screening program in preventing SCC in HIV patients. We demonstrate the advantages of progression towards SCC. Moreover, we used a new screening tool, the HR-VPS, a low-cost and manageable instrument to collect patients' long-term data

    Evaluation of 153 Asymptomatic Subjects Using the Anopress Portable Anal Manometry Device

    Full text link
    Background/Aims The Anopress device is a new portable manometry system. The aim of this study is to formulate normative data using this new device by recording the anorectal function of asymptomatic subjects. Patient comfort was also assessed. Methods Anorectal function was assessed in asymptomatic volunteers using the Anopress. All volunteers were examined in a standardized way in accordance with the study protocol. Normative values for the Anopress were obtained from the recorded data and patient comfort was assessed using a visual analogue scale. Results We recruited 153 healthy volunteers. Eighty were female (23 parous; median age 39.5 [interquartile range {IQR}, 28.75–53.00]) and 73 were male (median age 40.5 [IQR, 29.00–52.25]). For the female cohort, the following normal range (2.5–97.5 percentile) values were recorded across the whole anal canal: resting pressure 40.0–103.0 mmHg; squeeze increment 35.0–140.6 mmHg; endurance 1.3–9.0 seconds; involuntary squeeze 41.1–120.8 mmHg; and strain pressure 22.1–77.9 mmHg. Similarly, the following male normal range (2.5–97.5 percentile) values were recorded across the whole anal canal: resting pressure 38.3–99.6 mmHg; squeeze increment 42.5–154.8 mmHg; involuntary squeeze 40.0–123.6 mmHg; endurance 2.0–10.0 seconds; and strain pressure 11.0–72.1 mmHg. The median visual analogue scale scores for discomfort during the measurement was 0.0 (IQR, 0.00–0.00). Conclusions Normative values for the Anopress device have been calculated by this study. The Anopress appears to be a safe and well tolerated way of measuring pressures from the entire anal canal. Further comparisons with other standard and commonly used manometry tests are, however, required to verify its reliability

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Full text link
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Refining and improving the assessment and treatment of faecal incontinence

    Full text link
    Faecal incontinence (FI) is a common symptom. There are a variety of invasive treatments available, however, the benign nature of this problem and the varying degrees of severity, mean that conservative management is usually pursued first. The aims of this thesis were to investigate: the current practice of continence advisors who deliver conservative management in the community in the UK; assess and evaluate a new portable manometric device (THD® Anopress); investigate a new first line treatment for FI (Renew™) and compare this to another well-established non-invasive treatment (PTNS); report the long-term effectiveness of SNM; and, describe the short term outcome of the newer Sphinkeeper procedure. Results of this thesis lead to the conclusion that continence advisors are an important part of the management of FI in the community and that while they are able to utilise many of the current treatments, there is room for improvement. Normal range values for the new portable manometric device Anopress have been reported for the first time. It has been demonstrated that Anopress device appears able to detect anal sphincter dysfunction in those with symptomatic FI, and most importantly, Anopress measurements correlate strongly with water-perfused manometry. Results reported by this thesis also demonstrated that the Renew device is safe, well tolerated and an effective non-invasive treatment for passive FI. The randomized controlled trial suggests that both the Renew device and PTNS are effective treatments for FI, although Renew inserts may be more effective than PTNS. SNS was confirmed as an effective treatment for FI even in the long term with a consistent improvement of validated FI scores for approximately 60% of all patients reviewed at 11 years post implantation. Sphinkeeper was also demonstrated to be a safe and feasible alternative procedure for FI.Open Acces

    Dispelling the Myths Behind First-author Citation Counts

    Full text link
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods
    corecore