1,721,023 research outputs found
Lawrence Nathan and Gladys Atwood
Lawrence Nathan and Gladys Kidd Atwood pose for a portrait
Regular Solution Theory for Polymer Permeation Transients: A Toolkit for Understanding Experimental Waveshapes
The accurate measurement of permeation is important at the product design stage for a variety of industries as diverse as conveyance methods for oil and gas produced fluids, such as mixtures of carbon dioxide, methane, hydrogen sulfide, water, and hydrocarbons, and in polymer-lined, unbonded flexible risers and flow lines through connectors and valves, hydrogen and methane gas carrying domestic lines, hydrogen storage tanks, sulfur hexafluoride circuit breakers for high power-carrying lines, oxygen through display technology, and drug delivery. It would also be appropriate to monitor the permeation rate through the polymer, composite, and elastomeric layers during the in-service times where applications allow. In the future, any alteration in the short term and long-term transport rates could be analyzed in terms of an initial alteration or degradation of the polymeric materials and, in some cases, metallic components. Crucially, such measurements would serve as an early warning system of any change in a polymeric material that could result in the loss of function of the fluid of a gas containing barrier material. Most experimental determinations are made through recording flux transients (varying flux) through permeation cells in which a polymer membrane or film separates a donor compartment (usually an infinite supply) and an acceptor compartment and in which membrane transport is considered to be slow. Treatment of the resulting experimental data is usually, but not always, undertaken through comparison with a steady-state model based on Fickian diffusion through the membrane, so as to extract the membrane permeability, the diffusion coefficient of the permeant, and the solubility of the permeant in the membrane phase. However, in spite of these measurements being undertaken routinely using closed cell manometric or continuous flow methods, there is a lack of literature in which experimental flux transients are provided, and in several cases, it is clear that the experimental data do not conform to the expected model of slow, Fickian diffusion through the membrane, even though experiments are performed at temperatures much higher than the glass transition temperature of the polymer membrane. In this paper, we first re-examine the classical model for an infinite source and extend it to account for (1) molecular interactions between membrane and permeant, using regular solution theory, (2) slow transport in the acceptor phase, and (3) slow kinetics across the membrane|acceptor interface. We demonstrate that all three aspects can cause permeation flux transients to exhibit unusual, nonclassical waveshapes, which have nevertheless been experimentally realized without rationalization. This enables the development of an algorithmic toolkit for the interpretation of permeation flux transients, so as to provide reliable and accurate data analysis for experimentalists
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
koamabayili/VECTRON-author-checklist: VECTRON author checklist
We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
Author-wise bibliometric analysis based on entropy.
Author-wise bibliometric analysis based on entropy.</p
- …
