1,721,268 research outputs found

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Get PDF
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Improving Pyruvate Kinetic Measurements Using Variable Flip Angle Schemes in bSSFP Hyperpolarized Carbon-13 MR Imaging

    Get PDF
    Hyperpolarized MR imaging of 13C-labeled probes provide increased sensitivity to investigate metabolic kinetics. The characterization of [1-13C]pyruvate kinetics has been correlated to increased aggressiveness of Renal Cell Carcinoma (RCC) and pyruvate kinetics have the potential to be a valuable tool for assessing disease burden. Increased signal-to-noise ratio (SNR) has already been proven through the use of balanced steady-state free precession (bSSFP) sequences over accelerated gradient echo (GRE) acquisitions. A sigmoid-based variable flip angle scheme was implemented in a pyruvate-specific 3D bSSFP dynamic imaging protocol to further optimize the SNR across multiple acquisitions. The effects of varying flip angle across a dynamic imaging study was first simulated with a physics-based 2-site pyruvate-lactate kinetic model and then evaluated using Monte Carlo simulations for sensitivities to kinetic and imaging parameters. An increase in early lactate signal as well as a delayed pyruvate signal peak and extended signal window were confirmed with subsequent animal studies on a healthy adult rat. The resulting signal changes present the possibility of improved spatial resolution and improved kPL fitting. Additional studies and simulations to optimize associated sequence parameters are needed to further characterize the use-case for sigmoid-based variable flip angle schemes

    3D balanced SSFP UTE MRI for multiple contrasts whole brain imaging

    No full text
    Purpose: This study aimed to develop a new high-resolution MRI sequence for the imaging of the ultra-short transverse relaxation time (uT2) components in the brain, while simultaneously providing proton density (PD) contrast for reference and quantification. Theory: The sequence combines low flip angle balanced SSFP (bSSFP) and UTE techniques, together with a 3D dual-echo rosette k-space trajectory for readout. Methods: The expected image contrast was evaluated by simulations. A study cohort of six healthy volunteers and eight multiple sclerosis (MS) patients was recruited to test the proposed sequence. Subtraction between two TEs was performed to extract uT2 signals. In addition, conventional longitudinal relaxation time (T1) weighted, T2-weighted, and PD-weighted MRI sequences were also acquired for comparison. Results: Typical PD-contrast was found in the second TE images, while uT2 signals were selectively captured in the first TE images. The subtraction images presented signals primarily originating from uT2 components, but only if the first TE is short enough. Lesions in the MS subjects showed hyperintense signals in the second TE images but were hypointense signals in the subtraction images. The lesions had significantly lower signal intensity in subtraction images than normal white matter (WM), which indicated a reduction of uT2 components likely associated with myelin. Conclusion: 3D isotropic sub-millimeter (0.94 mm) spatial resolution images were acquired with the novel bSSFP UTE sequence within 3 min. It provided easy extraction of uT2 signals and PD-contrast for reference within a single acquisition

    Variations on the Author

    Get PDF
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
    corecore