1,720,955 research outputs found

    Hepatocellular carcinoma in cirrhotic patients: prospective comparison of US, CT and MR imaging

    No full text
    To prospectively compare the diagnostic performance of ultrasound (US), multidetector computed tomography (MDCT) and contrast-enhanced magnetic resonance imaging (MRI) in cirrhotic patients who were candidates for liver transplantation. One hundred and forty consecutive patients with 163 hepatocellular carcinoma (HCC) nodules underwent US, MRI and MDCT. Diagnosis of HCC was based on pathological findings or substantial growth at 12-month follow-up. Four different image datasets were evaluated: US, MDCT, MRI unenhanced and dynamic phases, MRI unenhanced dynamic and hepatobiliary phase. Diagnostic accuracy, sensitivity, specificity, PPV and NPV, with corresponding 95 % confidence intervals, were determined. Statistical analysis was performed for all lesions and for three lesion subgroups ( 2 cm). Significantly higher diagnostic accuracy, sensitivity and NPV was achieved on dynamic + hepatobiliary phase MRI compared with US, MDCT and dynamic phase MRI alone. The specificity and PPV of US was significantly lower than that of MDCT, dynamic phase MRI and dynamic + hepatobiliary phase MRI. Similar results were obtained for all sub-group analyses, with particular benefit for the diagnosis of smaller lesions between 1 and 2 cm. Dynamic + hepatobiliary phase MRI improved detection and characterisation of HCC in cirrhotic patients. The greatest benefit is for diagnosing lesions between 1 and 2 cm. aEuro cent US, CT and MRI can all identify HCC in cirrhotic patients aEuro cent US has good sensitivity but suffers from false-positive findings aEuro cent Dynamic CT and MR have similar diagnostic performance for diagnosing HCC aEuro cent Dynamic + hepatobiliary phase MRI significantly improves detection and characterisation of HCC aEuro cent The greatest benefit is for the diagnosis of lesions between 1 and 2 cm

    Hepatocellular carcinoma (HCC) in non-cirrhotic liver: clinical, radiological and pathological findings

    No full text
    Our aim was to evaluate the clinical and pathological findings, mutidetector-row computed tomography (MDCT) and magnetic resonance imaging (MRI) appearances, treatment and 1-year survival of patients with HCC in non-cirrhotic liver. Histopathological and laboratory findings of 30 non-cirrhotic patients with 32 HCCs were reviewed retrospectively. MDCT and gadobenate dimeglumine-enhanced MR images were evaluated in consensus by two radiologists in terms of HCC size, presence of tumour capsule, necrosis, haemorrhage, fat and calcification, and vascular involvement. Imaging patterns were compared directly with HCC findings in a matched group of cirrhotic patients. No differences between non-cirrhotic and cirrhotic patients were noted in terms of serum alpha-fetoprotein levels (elevated in 11 [36.7 %] and 21 [35 %] patients, respectively). The imaging appearance at CT and contrast-enhanced MRI was typical in 27 (84.3 %) and 28 (87.5 %) cases respectively. Most lesions presented as a well-differentiated large solitary mass, with well-defined margins, areas of necrosis and peripheral capsule. No significant differences in HCC pattern were observed between cirrhotic and non-cirrhotic liver. In non-cirrhotic patients, HCC is more likely to manifest as an asymptomatic mass with elevation of serum tumour markers similar to that seen in cirrhotic patients. HCC in cirrhotic and non-cirrhotic livers show similar enhancement patterns. HCC shows similar CT/MRI pattern in cirrhotic and non-cirrhotic livers. Non-invasive diagnostic criteria for HCC should also be extended to non-cirrhotic livers. No differences were found between alpha-fetoprotein levels in non-cirrhotic and cirrhotic patients

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Full text link
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Dispelling the Myths Behind First-author Citation Counts

    Full text link
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Author Index

    No full text
    Nao informado

    koamabayili/VECTRON-author-checklist: VECTRON author checklist

    No full text
    We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
    corecore