1,721,079 research outputs found

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Get PDF
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Get PDF
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Get PDF
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Dispelling the Myths Behind First-author Citation Counts

    Get PDF
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Author Index

    No full text
    Nao informado

    koamabayili/VECTRON-author-checklist: VECTRON author checklist

    No full text
    We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used

    The Role of Choline Positron Emission Tomography/Computed Tomography in the Management of Patients with Prostate-Specific Antigen Progression After Radical Treatment of Prostate Cancer

    No full text
    Context: Choline positron emission tomography (PET)/computed tomography (CT) is a currently used diagnostic tool in restaging prostate cancer (PCa) patients with increasing prostate-specific antigen (PSA) after either radical prostatectomy (RP) or external-beam radiation therapy (EBRT). However, no final recommendations have been made on the use of this modality for patient management. Objective: To critically analyse the current evidence for the use of choline PET/CT scanning in the management of patients with a progressive increase in PSA after radical treatment for PCa, evaluating its diagnostic accuracy in the detection of recurrences, the clinical predictors of positive PET/CT examinations, and the modalities' role as a guide for tailored therapeutic strategies. Evidence acquisition: Data on recently published (2003-2010) original articles, review articles, and editorials concerning the role of choline PET/CT in this scenario were analysed. Evidence synthesis: The diagnostic accuracy of choline PET in detecting sites of PCa relapse has been investigated by several authors, and the overall reported sensitivity ranges between 38% and 98%. It has been demonstrated that choline PET technology's positive detection rate improves with increasing PSA values. The routine use of choline PET/CT cannot be recommended for PSA values <1 ng/ml. However, in addition to PSA serum value, PSA doubling time (PSA DT), and other clinical and pathologic features-including locally advanced tumour (pT3b-T4) or lymph node involvement at initial staging-should be considered to refer patients to choline PET/CT study. Choline PET/CT may be also proposed as a image guide either for experimental surgical or radiation therapy treatments. Conclusions: According to the current available data, choline PET/CT plays a role in the management of biochemical relapse. Its accuracy is correlated to PSA value, PSA DT, and other pathologic features. Choline PET/CT may be proposed as a guide for individualised treatment of recurrence. (C) 2010 European Association of Urology. Published by Elsevier B.V. All rights reserved.Context: Choline positron emission tomography (PET)/computed tomography (CT) is a currently used diagnostic tool in restaging prostate cancer (PCa) patients with increasing prostate-specific antigen (PSA) after either radical prostatectomy (RP) or external-beam radiation therapy (EBRT). However, no final recommendations have been made on the use of this modality for patient management. Objective: To critically analyse the current evidence for the use of choline PET/CT scanning in the management of patients with a progressive increase in PSA after radical treatment for PCa, evaluating its diagnostic accuracy in the detection of recurrences, the clinical predictors of positive PET/CT examinations, and the modalities' role as a guide for tailored therapeutic strategies. Evidence acquisition: Data on recently published (2003-2010) original articles, review articles, and editorials concerning the role of choline PET/CT in this scenario were analysed. Evidence synthesis: The diagnostic accuracy of choline PET in detecting sites of PCa relapse has been investigated by several authors, and the overall reported sensitivity ranges between 38% and 98%. It has been demonstrated that choline PET technology's positive detection rate improves with increasing PSA values. The routine use of choline PET/CT cannot be recommended for PSA values <1 ng/ml. However, in addition to PSA serum value, PSA doubling time (PSA DT), and other clinical and pathologic features-including locally advanced tumour (pT3b-T4) or lymph node involvement at initial staging-should be considered to refer patients to choline PET/CT study. Choline PET/CT may be also proposed as a image guide either for experimental surgical or radiation therapy treatments. Conclusions: According to the current available data, choline PET/CT plays a role in the management of biochemical relapse. Its accuracy is correlated to PSA value, PSA DT, and other pathologic features. Choline PET/CT may be proposed as a guide for individualised treatment of recurrence. (C) 2010 European Association of Urology. Published by Elsevier B.V. All rights reserved

    Tumour hypoxia imaging with [F-18]FAZA PET in head and neck cancer patients: a pilot study

    No full text
    Purpose Hypoxia is an important negative prognostic factor for radiation treatment of head and neck cancer. This study was performed to evaluate the feasibility of use of F-18-labelled fluoroazomycin arabinoside ([F-18]FAZA) for clinical PET imaging of tumour hypoxia. Methods Eleven patients (age 59.6 +/- 9 years) with untreated advanced head and neck cancer were included. After injection of approximately 300 MBq of [F-18]FAZA, a dynamic sequence up to 60 min was acquired on an ECAT HR+ PET scanner. In addition, approximately 2 and 4 h p.i., static whole-body PET (n=5) or PET/CT (n=6) imaging was performed. PET data were reconstructed iteratively (OSEM) and fused with CT images (either an external CT or the CT of integrated PET/CT). Standardised uptake values (SUVs) and tumour-to-muscle (T/M) ratios were calculated in tumour and normal tissues. Also, the tumour volume displaying a T/M ratio > 1.5 was determined. Results Within the first 60 min of the dynamic sequence, the T/M ratio generally decreased, while generally increasing at later time points. At 2 h p.i., the tumour SUVmax and SUVmean were found to be 2.3 +/- 0.5 (range 1.5-3.4) and 1.4 +/- 0.3 (range 1.0-2.1), respectively. The mean T/M ratio at 2 h p.i. was 2.0 +/- 0.3 (range 1.6-2.4). The tumour volume displaying a T/M ratio above 1.5 was highly variable. At 2 h p.i., [F-18]FAZA organ distribution was determined as follows: kidney > gallbladder > liver > tumour > muscle > bone > brain > lung. Conclusion [F-18]FAZA PET imaging appears feasible in head and neck cancer patients, and the achieved image quality is adequate for clinical purposes. Based on our initial results, [F-18]FAZA warrants further evaluation as a hypoxia PET tracer for imaging of cancer
    corecore