1,720,970 research outputs found

    Perspectives and challenges of on-site quantification of organic pollutants in soils using solid-phase microextraction

    Get PDF
    This study explores the current state-of-the-art progress toward on-site quantification of organic pollutants in soils with solid-phase microextraction (SPME). In spite of many available methods, only few publications report on-site analyses of soil samples by SPME. To date, the only application of SPME for the on-site quantification of organic pollutants in soil has been devoted to trichloroethylene. The problem of matrix effects limiting quantification by external standard calibration is discussed. Efficiencies of available approaches for decreasing and controlling matrix effects are evaluated and compared. SPME from a soil sample headspace with internal standard calibration was identified as one of the promising approaches to achieve fast, simple, precise, and accurate on-site quantification of a wide range of organic pollutants in soil. Cold-fiber SPME has a significant development potential, because it is capable of providing lowest detection limits together with a minimum matrix effect. Perspectives for future development of the field are outlined.This is a manuscript of an article published as Kenessov, Bulat, Jacek A. Koziel, Nadezhda V. Bakaikina, and Dina Orazbayeva. "Perspectives and challenges of on-site quantification of organic pollutants in soils using solid-phase microextraction." TrAC Trends in Analytical Chemistry 85 (2016): 111-122. DOI: 10.1016/j.trac.2016.04.007. Posted with permission.</p

    Screening of transformation products in soils contaminated with unsymmetrical dimethylhydrazine using headspace SPME and GC–MS

    No full text
    The paper describes a novel SPME-based approach for sampling and analysis of transformation products of highly reactive and toxic unsymmetrical dimethylhydrazine (UDMH) which is used as a fuel in many Russian, European, Indian, and Chinese heavy cargo carrier rockets. The effects of several parameters were studied to optimize analyte recovery. It was found that the 85 μm Carboxen/polydimethylsiloxane fiber coating provides the highest selectivity for selected UDMH transformation products. Optimal sampling/sample preparation parameters were determined to be 1-h soil headspace sampling time at 40 °C. The GC inlet temperature was optimized to 170 °C held for 0.1 min, then 1 °C s−1 ramp to 250 °C where it was held for 40 min. Temperature programing resulted in a fast desorption along with minimal chemical transformation in the GC inlet. SPME was very effective extracting UDMH transformation products from soil samples contaminated with rocket fuel. The use of SPME resulted in high sensitivity, speed, small labor consumption due to an automation and simplicity of use. It was shown that water addition to soil leads to a significant decrease of recovery of almost all target transformation products of UDMH. The use of SPME for sampling and sample preparation resulted in detection of the total of 21 new compounds that are relevant to the UDMH transformation in soils. In addition, the number of confirmed transformation products of UDMH increased from 15 to 27. This sampling/sample preparation approach can be recommended for environmental assessment of soil samples from areas affected by space rocket activity.This is a manuscript of an article published as Kenessov, Bulat N., Jacek A. Koziel, Tim Grotenhuis, and Lars Carlsen. "Screening of transformation products in soils contaminated with unsymmetrical dimethylhydrazine using headspace SPME and GC–MS." Analytica Chimica Acta 674, no. 1 (2010): 32-39. DOI: 10.1016/j.aca.2010.05.040. Posted with permission.</p

    Modeling solid-phase microextraction of volatile organic compounds by porous coatings using finite element analysis

    Get PDF
    Experimental optimization of analytical methods based on solid-phase microextraction (SPME) is a complex and labor-intensive process associated with uncertainties. Using the theoretical basics of SPME and finite element analysis software for the optimization proved to be an efficient alternative. In this study, an improved finite element analysis-based model for SPME of volatile organic compounds (VOCs) by porous coatings was developed mainly focussing on the mass transport in coatings. Benzene and the Carboxen/polydimethylsiloxane (Car/PDMS) coating were used as the model VOC and a porous SPME coating, respectively. It has been established that in the coating, volumetric fractions of Carboxen, PDMS, and air are 33, 42 and 24%, respectively. Knudsen diffusion in micropores can slow down a mass transport of analytes in the coating. When PDMS was considered as the solid part of the coating, lower root-mean-square deviation of the modeling results from experimental data was observed. It has been shown that the developed model can be used to model the extraction of VOCs from air and water samples encountered in a typical SPME development method procedure. It was possible to determine system equilibration times and use them to optimize sample volume and Henry's law constant. The developed model is relatively simple, fast, and can be recommended for optimization of extraction parameters for other analytes and SPME coatings. The diffusivity of analytes in a coating is an important property needed for improved characterization of existing and new SPME polymers and analytical method optimization.This article is published as Kenessov, Bulat, Miras Derbissalin, Jacek A. Koziel, and Dmitry S. Kosyakov. "Modeling solid-phase microextraction of volatile organic compounds by porous coatings using finite element analysis." Analytica Chimica Acta 1076 (2019): 73-81. DOI: 10.1016/j.aca.2019.05.042. Posted with permission.</p

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Get PDF
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Get PDF
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Get PDF
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Dispelling the Myths Behind First-author Citation Counts

    Get PDF
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Author Index

    No full text
    Nao informado

    koamabayili/VECTRON-author-checklist: VECTRON author checklist

    No full text
    We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
    corecore