1,720,958 research outputs found
Low-complexity hardware design methodology for reliable and automated removal of ocular and muscular artifact from EEG
Background and objective: EEG is a non-invasive tool for neuro-developmental disorder diagnosis and treatment. However, EEG signal is mixed with other biological signals including Ocular and Muscular artifacts making it difficult to extract the diagnostic features. Therefore, the contaminated EEG channels are often discarded by the medical practitioners which may result in less accurate diagnosis. Many existing methods require reference electrodes, which will create discomfort to the patient/children and cause hindrance to the diagnosis of the neuro-developmental disorder and Brain Computer Interface in the pervasive environment. Therefore, it would be ideal if these artifacts can be removed real time on the hardware platform in an automated fashion and then the denoised EEG can be used for online diagnosis in a pervasive personalized healthcare environment without the need of any reference electrode. Methods: In this paper we propose a reliable, robust and automated methodology to solve the aforementioned problem. The proposed methodology is based on the Haar function based Wavelet decompositions with simple threshold based wavelet domain denoising and artifacts removal schemes. Subsequently hardware implementation results are also presented. 100 EEG data from Physionet, Klinik für Epileptologie, Universität Bonn, Germany, Caltech EEG databases and 7 EEG data from 3 subjects from University of Southampton, UK have been studied and nine exhaustive case studies comprising of real and simulated data have been formulated and tested. The proposed methodology is prototyped and validated using FPGA platform. Results: Like existing literature, the performance of the proposed methodology is also measured in terms of correlation, regression and R-square statistics and the respective values lie above 80%, 79% and 65% with the gain in hardware complexity of 64.28% and improvement in hardware delay of 53.58% compared to state-of-the art approaches. Hardware design based on the proposed methodology consumes 75 micro-Watt power. Conclusions: The automated methodology proposed in this paper, unlike the state of the art methods, can remove blink and muscular artifacts real time without the need of any extra electrode. Its reliability and robustness is also established after exhaustive simulation study and analysis on both simulated and real data. We believe the proposed methodology would be useful in next generation personalized pervasive healthcare for Brain Computer Interface and neuro-developmental disorder diagnosis and treatment. © 2018 Elsevier B.V
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Automated and Reliable Low-Complexity SoC Design Methodology for EEG Artefacts Removal
EEG is a non-invasive tool for neurodevelopmental disorder diagnosis (NDD) and treatment. However,
EEG signal is mixed with other biological signals including Ocular and Muscular artefacts making
it difficult to extract the diagnostic features. Therefore, the contaminated EEG channels are often discarded
by the medical practitioners which may result in less accurate diagnosis. Independent Component
Analysis (ICA) and wavelet-based algorithms require reference electrodes, which will create discomfort
to the patient/children and cause hindrance to the diagnosis of the NDD and Brain Computer Interface
(BCI). Therefore, it would be ideal if these artefacts can be removed real time and on hardware platform
in an automated fashion and denoised EEG can be used for online diagnosis in a pervasive personalised
healthcare environment without the need of any reference electrode. In this thesis we propose a reliable,
robust and automated methodology to solve the aforementioned problem and its subsequent hardware
implementation results are also presented. 100 EEG data from Physionet, Klinik fur Epileptologie, Universitat
Bonn, Germany, Caltech EEG databases and 3 EEG data from 3 subjects from University of
Southampton, UK have been studied and nine exhaustive case studies comprising of real and simulated
data have been formulated and tested. The performance of the proposed methodology is measured in
terms of correlation, regression and R-square statistics and the respective values lie above 80%, 79% and
65% with the gain in hardware complexity of 64.28% and hardware delay 53.58% compared to state-ofthe
art approach. We believe the proposed methodology would be useful in next generation of pervasive
healthcare for BCI and NDD diagnosis and treatment
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
koamabayili/VECTRON-author-checklist: VECTRON author checklist
We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
Author-wise bibliometric analysis based on entropy.
Author-wise bibliometric analysis based on entropy.</p
- …
