16 research outputs found
FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging—version 1.0. Eur J Nucl Med Mol Imaging
General rights It is not permitted to download or to forward/distribute the text or part of it without the consent of the author(s) and/or copyright holder(s), other than for strictly personal, individual use, unless the work is under an open content license (like Creative Commons). Disclaimer/Complaints regulations If you believe that digital publication of certain material infringes any of your rights or (privacy) interests, please let the Library know, stating your reasons. In case of a legitimate complaint, the Library will make the material inaccessible and/or remove it from the website. Please Ask the Library: https://uba.uva.nl/en/contact, or a letter to: Library of the University of Amsterdam, Secretariat, Singel 425, 1012 WP Amsterdam, The Netherlands. You will be contacted as soon as possible
How should we analyse FDG PET studies for monitoring tumour response?
FDG PET is a promising technique for monitoring tumour response early during anticancer therapy. Progress, however, has been limited owing to the multitude of methods currently in use. Here, the most promising techniques for multi-centre trials are discussed briefly, with emphasis on the need for standardisation. In addition, an approach is presented for response monitoring studies using newly developed drugs. This approach makes use of a large database of response monitoring studies, which defines the relationship between simplified clinical methods and full quantitative analysis for classic cytotoxic drugs. For a new drug, first a pilot study is performed to assess whether it affects this relationship. Based on this pilot, it is decided whether or not a simplified clinical method can be used in further studies
Measurement of perfusion in stage IIIA-N2 non-small cell lung cancer using H215O and positron emission tomography
Purpose: As the interest in antiangiogenesis therapy in oncology is rising, the need for in vivo techniques to monitor such therapy is obvious. Measurement of tumor perfusion using positron emission tomography and H215O potentially is such a technique. The objective of the present study was to assess whether it is feasible to measure perfusion in vivo in non-small cell lung cancer (NSCLC) using H215O and positron emission tomography. Experimental Design: Fifteen dynamic H215O and [18F]2-fluoro-2-deoxy-D-glucose (18FDG) studies were performed in 10 patients with stage IIIA-N2 NSCLC. Blood flow (BF) data were correlated with simplified methods of analysis (tumor:normal tissue ratio and standardized uptake value) and with glucose metabolism (MRglu). Results: 18FDG data were required for accurate definition of tumor and mediastinal lymph node metastases. There was large intertumor variation in BF. Correlation of simplified methods of analysis with quantitative BF was poor. In addition, BF and MRglu were not correlated. Conclusion: Measurement of BF in NSCLC using H215O and 18FDG is feasible. Simple uptake analysis, however, cannot be used as an indicator of perfusion. Whether BF can be used for response monitoring needs to be evaluated in a large patient study, where results can be compared with outcome
Effects of ROI definition and reconstruction method on quantitative outcome and applicability in a response monitoring trial
Purpose: Quantitative measurement of tracer uptake in a tumour can be influenced by a number of factors, including the method of defining regions of interest (ROIs) and the reconstruction parameters used. The main purpose of this study was to determine the effects of different ROI methods on quantitative outcome, using two reconstruction methods and the standard uptake value (SUV) as a simple quantitative measure of FDG uptake. Methods: Four commonly used methods of ROI definition (manual placement, fixed dimensions, threshold based and maximum pixel value) were used to calculate SUV (SU
Methods to monitor response to chemotherapy in non-small cell lung cancer with 18F-FDG PET
PET using 18F-FDG is a promising technique to monitor response in oncology. Unfortunately, a multitude of analytic methods is in use. To date, it is not clear whether simplified methods could replace complex quantitative methods in routine clinical practice. The aim of this study was to select those methods that would qualify for further assessment in a future prospective response-monitoring study by comparing results with patient outcome. Methods: Dynamic 18F-FDG PET scans were obtained on 2 groups of patients. First, 10 patients with advanced non-small cell lung cancer (NSCLC) were scanned on consecutive days before treatment to assess test-retest variability. Second, 30 scans were obtained on 19 patients with locally advanced NSCLC as part of an ongoing response-monitoring study. These scans were analyzed by 2 observers to assess observer variability. In addition, these studies were used to compare various methods with the gold standard, full kinetic analysis (nonlinear regression [NLR]). Results: Using an imagederived input function, NLR showed excellent test-retest and observer agreement confirming that it could be used as a gold standard method. From a total of 34 analytic methods, 10 showed good correlation with NLR. Taking into account the degree of complexity of the methods, 4 remain for further evaluation. Conclusion: The optimal method for analysis of 18F-FDG PET data was determined for several levels of complexity. Four methods need to be evaluated further to determine the optimal trade-off between simplicity and accuracy for routine clinical practice
Positron emission tomography using 2-deoxy-2-[18 F]-fluoro-D-glucose for response monitoring in locally advanced gastroesophageal cancer; a comparison of different analytical methods
Purpose: To determine the ability of 2-deoxy-2-[18F] -fluoro-D-glucose (FDG) positron emission tomography (PET) to monitor response in locally advanced gastroesophageal cancer (LAGEC). Additionally, optimal FDG-PET methods for response monitoring were selected. Procedures: Sequential dynamic FDG-PET scans were performed in 13 patients with LAGEC (T2-3N0-1M0-1a) treated with neoadjuvant cisplatin and gemcitabine plus granulocyte macrophage colony stimulating growth factor at a three weekly schedule. The standard FDG-PET method, nonlinear regression (NLR), was compared with computed tomography (CT), endoscopic-ultrasound (EUS), and histopathology as well as with 21 simplified analytical FDG-PET methods. Results: Five out of 12 operated tumors responded histopathologically with less than 10% residual tumorcells (42%). These had a higher decrease in FDG uptake compared with nonresponders (P = 0.008). Early (after two cycles) and late (after completed induction therapy) response evaluation showed a specificity of 86% and 100%, respectively, and a sensitivity of 100%. Both FDG-PET and EUS were superior to CT. From 21 methods analyzing FDG uptake, the quantitative Patlak analysis, the simplified kinetic method (SKM), and the semiquantitative standardized uptake value corrected for bodyweight (SUV-BW) seemed to correlate best with NLR. Conclusions: FDG-PET reliably predicted response in LAGEC. FDG-PET measurements using Patlak analysis or the more clinical applicable SKM and SUV-BW were acceptable alternatives to NLR
The Netherlands protocol for standardisation and quantification of FDG whole body PET studies in multi-centre trials.
Contains fulltext :
70810.pdf (Publisher’s version ) (Open Access)INTRODUCTION: Several studies have shown the usefulness of positron emission tomography (PET) quantification using standardised uptake values (SUV) for diagnosis and staging, prognosis and response monitoring. Many factors affect SUV, such as patient preparation procedures, scan acquisition, image reconstruction and data analysis settings, and the variability in methodology across centres prohibits exchange of SUV data. Therefore, standardisation of 2-[(18)F] fluoro-2-deoxy-D-glucose (FDG) PET whole body procedures is required in multi-centre trials. METHODS: A protocol for standardisation of quantitative FDG whole body PET studies in the Netherlands (NL) was defined. This protocol is based on standardisation of: (1) patient preparation; (2) matching of scan statistics by prescribing dosage as function of patient weight, scan time per bed position, percentage of bed overlap and image acquisition mode (2D or 3D); (3) matching of image resolution by prescribing reconstruction settings for each type of scanner; (4) matching of data analysis procedure by defining volume of interest methods and SUV calculations and; (5) finally, a multi-centre QC procedure is defined using a 20-cm diameter phantom for verification of scanner calibration and the NEMA NU 2 2001 Image Quality phantom for verification of activity concentration recoveries (i.e., verification of image resolution and reconstruction convergence). DISCUSSION: This paper describes a protocol for standardization of quantitative FDG whole body multi-centre PET studies. CONCLUSION: The protocol was successfully implemented in the Netherlands and has been approved by the Netherlands Society of Nuclear Medicine
Prognostic relevance of response evaluation using [18F]-2- fluoro-2-deoxy-D-glucose positron emission tomography in patients with locally advanced non-small-cell lung cancer
Purpose: The objective of this study was to determine the accuracy of (early) response measurements using [18F]-2-fluoro-2-deoxy-D-glucose positron emission tomography (18FDG PET) with respect to survival of patients with stage IIIA-N2 non-small-cell lung cancer (NSCLC) undergoing induction chemotherapy (IC), with a comparative analysis of PET methods. Patients and Methods: In a prospective multicenter study, PET was performed in patients before IC and after one and three cycles. Computed tomography (CT) was performed before and after IC. Glucose consumption (metabolic rate of glucose [MRglu]) was measured using Patlak graphical analysis and correlated with simplified methods. Mediastinal lymph node (MLN) status was assessed visually. Cox proportional hazards analysis was used to determine the prognostic relevance of CT and PET measures of response with respect to survival. Results: Complete PET data sets were available in 47 patients. Median survival was 21 months. MLN status after IC by PET predicted survival (hazard ratio [HR], 2.33; 95% CI, 1.04 to 5.22; P = .04) in contrast with CT (HR, 1.87; 95% CI, 0.81 to 4.30; P = .14). Residual MRglu after IC proved to be the best prognostic factor (HR, 1.95; 95% CI, 1.28 to 2.97; P = .002). Multivariate stepwise analysis showed that PET identified prognostically different strata in patients considered responsive according to CT. Residual MRglu after one cycle selected patients with different outcomes (HR, 2.04; 95% CI, 1.18 to 3.52; P = .01). Simplified quantitative 18FDG PET methods were correlated with Patlak graphical analysis during and after therapy (r ≥ 0.90). Conclusion: 18FDG PET has additional value over CT in monitoring response to IC in patients with stage IIIA-N2 NSCLC, and it seems feasible to predict survival early during IC. Simple semiquantitative and complex PET methods perform equally well
Stability of FDG-PET Radiomics features: an integrated analysis of test-retest and inter-observer variability.
PURPOSE: Besides basic measurements as maximum standardized uptake value (SUV)max or SUVmean derived from 18F-FDG positron emission tomography (PET) scans, more advanced quantitative imaging features (i.e. "Radiomics" features) are increasingly investigated for treatment monitoring, outcome prediction, or as potential biomarkers. With these prospected applications of Radiomics features, it is a requisite that they provide robust and reliable measurements. The aim of our study was therefore to perform an integrated stability analysis of a large number of PET-derived features in non-small cell lung carcinoma (NSCLC), based on both a test-retest and an inter-observer setup.\n\nMETHODS: Eleven NSCLC patients were included in the test-retest cohort. Patients underwent repeated PET imaging within a one day interval, before any treatment was delivered. Lesions were delineated by applying a threshold of 50% of the maximum uptake value within the tumor. Twenty-three NSCLC patients were included in the inter-observer cohort. Patients underwent a diagnostic whole body PET-computed tomography (CT). Lesions were manually delineated based on fused PET-CT, using a standardized clinical delineation protocol. Delineation was performed independently by five observers, blinded to each other. Fifteen first order statistics, 39 descriptors of intensity volume histograms, eight geometric features and 44 textural features were extracted. For every feature, test-retest and inter-observer stability was assessed with the intra-class correlation coefficient (ICC) and the coefficient of variability, normalized to mean and range. Similarity between test-retest and inter-observer stability rankings of features was assessed with Spearman's rank correlation coefficient.\n\nRESULTS: Results showed that the majority of assessed features had both a high test-retest (71%) and inter-observer (91%) stability in terms of their ICC. Overall, features more stable in repeated PET imaging were also found to be more robust against inter-observer variability.\n\nCONCLUSION: Results suggest that further research of quantitative imaging features is warranted with respect to more advanced applications of PET imaging as being used for treatment monitoring, outcome prediction or imaging biomarkers
FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0
The purpose of these guidelines is to assist physicians in recommending, performing, interpreting and reporting the results of FDG PET/CT for oncological imaging of adult patients. PET is a quantitative imaging technique and therefore requires a common quality control (QC)/quality assurance (QA) procedure to maintain the accuracy and precision of quantitation. Repeatability and reproducibility are two essential requirements for any quantitative measurement and/or imaging biomarker. Repeatability relates to the uncertainty in obtaining the same result in the same patient when he or she is examined more than once on the same system. However, imaging biomarkers should also have adequate reproducibility, i.e. the ability to yield the same result in the same patient when that patient is examined on different systems and at different imaging sites. Adequate repeatability and reproducibility are essential for the clinical management of patients and the use of FDG PET/CT within multicentre trials. A common standardised imaging procedure will help promote the appropriate use of FDG PET/CT imaging and increase the value of publications and, therefore, their contribution to evidence-based medicine. Moreover, consistency in numerical values between platforms and institutes that acquire the data will potentially enhance the role of semiquantitative and quantitative image interpretation. Precision and accuracy are additionally important as FDG PET/CT is used to evaluate tumour response as well as for diagnosis, prognosis and staging. Therefore both the previous and these new guidelines specifically aim to achieve standardised uptake value harmonisation in multicentre settings
