169,724 research outputs found
Variability of the hemodynamic response in infants: Influence of experimental design and stimulus complexity
Measuring brain activity in developmental populations remains a major challenge despite great technological advances. Among the numerous available methods, functional near-infrared spectroscopy (fNIRS), an imaging modality that probes the hemodynamic response, is a powerful tool for recording brain activity in a great variety of situations and populations. Neurocognitive studies with infants have often reported inverted hemodynamic responses, i.e. a decrease instead of an increase in regional blood oxygenation, but the exact physiological explanation and cognitive interpretation of this response remain unclear. Here, we first provide an overview of the basic principles of NIRS and its use in cognitive developmental neuroscience. We then review the infant fNIRS literature to show that the hemodynamic response is modulated by experimental design and stimulus complexity, sometimes leading to hemodynamic responses with non-canonical shapes. We also argue that this effect is further modulated by the age of participants, the cortical regions involved, and the developmental stage of the tested cognitive process. We argue that this variability needs to be taken into account when designing and interpreting developmental studies measuring the hemodynamic response. Keywords: fNIRS, Inverted Hemodynamic Response, Experimental complexity, Infants, Developmen
Adult-like processing of time-compressed speech by newborns: A NIRS study
AbstractHumans can adapt to a wide range of variations in the speech signal, maintaining an invariant representation of the linguistic information it contains. Among them, adaptation to rapid or time-compressed speech has been well studied in adults, but the developmental origin of this capacity remains unknown. Does this ability depend on experience with speech (if yes, as heard in utero or as heard postnatally), with sounds in general or is it experience-independent? Using near-infrared spectroscopy, we show that the newborn brain can discriminate between three different compression rates: normal, i.e. 100% of the original duration, moderately compressed, i.e. 60% of original duration and highly compressed, i.e. 30% of original duration. Even more interestingly, responses to normal and moderately compressed speech are similar, showing a canonical hemodynamic response in the left temporoparietal, right frontal and right temporal cortex, while responses to highly compressed speech are inverted, showing a decrease in oxyhemoglobin concentration. These results mirror those found in adults, who readily adapt to moderately compressed, but not to highly compressed speech, showing that adaptation to time-compressed speech requires little or no experience with speech, and happens at an auditory, and not at a more abstract linguistic level
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Mitomycin C in highly myopic eyes - Author reply
Ophthalmology. 2005 Feb;112(2):208-18; discussion 219.
Mitomycin C modulation of corneal wound healing after photorefractive keratectomy in highly myopic eyes.
Gambato C, Ghirlando A, Moretto E, Busato F, Midena E.
SourceRefractive Surgery Service and Antimetabolite Therapy Research Unit, Department of Ophthalmology, University of Padova, Padova, Italy.
Abstract
PURPOSE: To evaluate the role of topical mitomycin C in corneal wound healing (CWH) after photorefractive keratectomy (PRK) in highly myopic eyes.
DESIGN: Prospective, double-masked, randomized clinical trial.
PARTICIPANTS: Seventy-two eyes of 36 patients affected by high (>7 diopters) myopia.
METHODS: In each patient, one eye was randomly assigned to PRK with intraoperative topical 0.02% mitomycin C application, and the fellow eye was treated with a placebo. Postoperatively, mitomycin C-treated eyes received artificial tears (3 times daily, tapered in 3 months), whereas the fellow eye was treated with fluorometholone sodium 2% and artificial tears (3 times daily, tapered in 3 months).
MAIN OUTCOME MEASURES: Uncorrected visual acuity (UCVA) and best-corrected visual acuity (BCVA), contrast sensitivity, manifest refraction, and biomicroscopy. Contrast sensitivity was determined using the Pelli-Robson chart. Corneal confocal microscopy documented CWH.
RESULTS: Mean follow-up was 18 months (range, 12-36). No side effects or toxic effects were documented. At 12-month follow-up examination, UCVAs (logarithm of the minimum angle of resolution) were 0.4+/-0.48 and 0.5+/-0.53 (P = .03) in mitomycin C-treated eyes and corticosteroid-treated eyes, respectively. At 1 year, corneal haze developed in 20% of corticosteroid-treated eyes, versus 0% of mitomycin C-treated eyes. At 12, 24, and 36 months, corneal confocal microscopy showed activated keratocytes and extracellular matrix significantly more evident in untreated eyes (Ps = 0.004, 0.024, and 0.046, respectively).
CONCLUSION: Topical intraoperative application of 0.02% mitomycin C can reduce haze formation in highly myopic eyes undergoing PRK.
Comment in
Ophthalmology. 2006 Feb;113(2):357; author reply 357-8
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
Efficacy and safety of subcutaneous interferon beta-1a in relapsing-remitting multiple sclerosis: Further outcomes from the IMPROVE study
BACKGROUND:
The IMPROVE study demonstrated that the fetal bovine serum (FBS)- and human serum albumin (HSA)-free formulation of subcutaneous (sc) interferon (IFN) beta-1a had beneficial effects on the numbers of combined unique active magnetic resonance imaging (MRI) lesions in relapsing-remitting multiple sclerosis (RRMS). Here we report additional MRI endpoints (including post hoc analyses), and clinical efficacy, safety, and immunogenicity outcomes.
METHODS:
Patients with active RRMS were randomized (2:1) to IFN beta-1a, 44 mcg sc three times weekly (tiw) (n=120), or placebo (n=60), for 16 weeks (double-blind phase). All patients then received IFN beta-1a, 44 mcg sc tiw, for 24 weeks (rater-blind phase). Patients underwent MRI brain scans every 4 weeks.
RESULTS:
Compared with placebo, there was a 68% reduction in the mean cumulative number of new gadolinium-enhancing lesions with IFN beta-1a as early as week 4 (p<0.001), and a 53% reduction in the mean cumulative number of new T2 lesions as early as week 8 (p=0.025; post hoc analyses). During the 16-week double-blind phase, the relapse rate was 0.14 (95% confidence interval [CI] 0.09-0.23) with IFN beta-1a and 0.33 (95% CI 0.22-0.52) with placebo (p=0.010). Safety outcomes were consistent with those expected with IFN-beta treatment.
CONCLUSIONS:
The FBS/HSA-free formulation of sc IFN beta-1a has a beneficial impact on MRI and efficacy outcomes as early as 4 weeks after treatment initiation in patients with RRMS and has a safety profile consistent with previous trials of sc IFN beta-1a
Rapid benefits of a new formulation of subcutaneous interferon beta-1a in relapsing-remitting multiple sclerosis
This study evaluated the efficacy of a new formulation of subcutaneous (sc) interferon (IFN)-beta1a in relapsing-remitting multiple sclerosis (RRMS). Patients (n = 180) were randomized (2 : 1) to IFN-beta1a or placebo for 16 weeks; all patients then received IFN-beta1a for 24 weeks. Monthly brain MRI was performed. At week 16, the mean number of combined unique active (CUA) lesions was lower with IFN-beta1a than with placebo (p < 0.001; 69% fewer lesions). The mean cumulative number of CUA lesions was already lower with IFN-beta1a by week 4 (post hoc analysis; p = 0.015). The new formulation of sc IFN-beta1a has rapid beneficial effects on MRI outcomes in RRMS
A Multi-Language Comparison of Influences on Author Verification using Character N-Grams
We create a new multi-language corpus for author verification based on Wikipedia talkpages, and evaluate the influence that differences in topic and time have on character n-gram author profiles. Topic alignment between two texts is found to increase author verification precision, and an authors writing style is found to change over time, but not more significantly after 3 years than after 1 year.Information ArchitectureWISElectrical Engineering, Mathematics and Computer Scienc
A 0.12mm<sup>2</sup> Wien-Bridge Temperature Sensor with 0.1°C (3σ) Inaccuracy from -40°C to 180°C
Resistor-based temperature sensors can achieve much higher resolution and energy efficiency than conventional BJT-based sensors [1], but they typically occupy more area (> 0.25 mm 2 ) and have lower operating temperatures (le 125 {circ} {C}) [2]-[4]. This work describes a 0.12mm 2 resistor-based sensor that uses a Wien-bridge (WB) filter to achieve 0.1 {circ} {C} (3 sigma) inaccuracy from - 40 {circ} {C} to 180 {circ} {C}. Compared to a state-of-the-art WB sensor [4], it occupies 6 × less area and achieves comparable relative accuracy over a 76% wider operating range. Session 10.3 Green Open Access added to TU Delft Institutional Repository ‘You share, we take care!’ – Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.Electronic InstrumentationMicroelectronic
A ±25A Versatile Shunt-Based Current Sensor with 10kHz Bandwidth and ±0.25% Gain Error from -40°C to 85°C Using 2-Current Calibration
Accurate current sensing is critical in many industrial applications, such as battery management and motor control. Precise shunt-based current sensors have been reported with gain errors of less than 1% over the industrial temperature range (-40°C to 85°C) [1]–[4]. However, since they are intended for coulomb counting, their bandwidth is limited to a few tens of Hz, making them unsuitable for battery impedance or motor-current sensing. This paper presents a current sensor with a wide (10kHz) bandwidth and a tunable temperature compensation scheme (TCS), which allows it to be flexibly used with different types of shunts while maintaining high accuracy. A low-cost room-temperature calibration scheme is proposed to optimize gain flatness over temperature by exploiting the shunt's self-heating at large currents. Over the industrial temperature range and a ±25A current range, it achieves state-of-the-art gain error (±0.25%) with both low-cost PCB and stable metal-alloy shunts.Green Open Access added to TU Delft Institutional Repository 'You share, we take care!' - Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.Electronic InstrumentationMicroelectronic
- …
