1,720,952 research outputs found

    Design and Experimental Validation of Intracardiac Photoacoustic Catheter: English

    No full text
    Atrial fibrillation is a cardiac arrhythmia resulting from abnormal electrical conduction and impulse formation within the atria. To address this condition, a minimally invasive procedure called cardiac ablation is performed. Real-time visual feedback during this procedure plays a critical role in determining its success.Photoacoustic imaging is a technique capable of providing real-time visual feedback. Integrating photoacoustic capabilities into existing Radiofrequency ablation catheters poses a significant challenge, which this thesis addresses. The proposed integrated solution employs optical fibers for light delivery and an ultrasound transducer for signal reception.This work investigates the design of two light delivery systems for integrated photoacoustic-guided surgery. Monte Carlo simulations are employed to study three-dimensional light propagation in tissue, informing the catheter design specifications. Optimal fiber distances and orientations within the catheter are determined based on normalized fluence values and illumination spot size—critical parameters for assessing the amount of delivered light, its area of coverage, and depth of penetration. The methodology presented applies to various photoacoustic applications.The simulation study was able to successfully inform design specifications and it was able to establish a relation between design variables and the evaluation criteria such that it can be referred to for future designs. The comparative study yielded a better-performing design configuration and its optimal specifications were found out. This proves the use of a simulation-based evaluation to design a photoacoustic intracardiac catheter. In the final phase of this research, an experiment is set up to validate the light delivery of the design, which provides a clear outlook for the future of these designs into fabricated products.Mechanical Engineering | High-Tech Engineerin

    Depth-resolved dynamics in turbid media via frequency-modulated scattering holography

    No full text
    Interferometric diffuse optics (iDO) enables non-invasive measurement of deep tissue blood flow without requiring photon-counting detectors. Due to hardware constraints, achieving both optical properties and depth-dependent dynamics within a single modality remains a challenge for iDO. We present a simple method based on frequency-modulated light scattering that overcomes this limitation. © 2025 The Author(s

    Improving Access to Laparoscopic Bilateral Tubal Ligation in LMICs: A Novel Lifting Device with an Integrated Imaging System

    No full text
    Background: Bilateral tubal ligation (BTL) is the most common method of contraception worldwide because it is safe and effective. However, its accessibility remains unequal among women in rural India, in part due to a lack of laparoscopic equipment. Rural hospitals therefore resort to gas insufflation-less laparoscopic surgery (GILLS) because it requires less complex equipment. The pneumoperitoneum is replaced by an abdominal wall lift (AWL) device, but these devices suffer from limitations concerning visibility and working space.Methods: Initiated by the identified medical needs in rural India, a novel AWL device with an integrated imaging system is designed based on methods from literature and input from local end-users. It is a stainless steel hollow circular hook housing an LED lighting system and a 5 MP camera module. It can be connected to any laptop with a USB-A port. The device substitutes for both the traditional AWL device and currently used laparoscopes. The design is exemplified by a fully functional aluminium prototype used for verification and validation.Results: The selected camera module is the key technology of this design because it provides state-of-the-art imaging at an unmatched price point. The lighting system used for the prototype does not provide enough light, has an asymmetric illumination distribution, and generates too much heat. A structural strength test showed that the strength of the prototype exceeds the material-adjusted design load by 30%. Furthermore, the prototype is cost-effective, lightweight, compatible with current AWL systems, and has limited waterproofness. User tests with an expert rural surgeon confirmed that this design has the potential to improve surgical outcomes of BTL and other procedures, and can increase access to specialized medical care in rural India.Conclusions: It is strongly recommended to continue the development of this AWL device. The focus points should be the shape and size of the loop (and related cost-effective production techniques), a new lighting system, and the waterproofness of the device. Collaboration with rural surgeons and local biomedical engineers is crucial for context-driven development and implementation.Mechanical Engineerin

    Structured Illumination Imaging and Improvements in Scattering Medium

    No full text
    Bio-imaging plays an essential role in life sciences and medicine. Recently, structured illumination has emerged as a promising super-resolution technique. However, in the case of thick scattering media, the benefits of structured illumination can be significantly reduced compared to conventional illumination methods, resulting in significant degradation of imaging quality. Therefore, the question of dealing with the challenges posed by structured illumination in scattering media has become a topic of considerable focus. In this thesis, an experimental setup aimed at achieving super-resolution imaging using structured illumination is developed. The factors influencing the imaging process are systematically analyzed. At the same time, machine learning methods for recovering structured illumination patterns propagated through scattering media are explored. Overall, this research tackles the challenge of improving super-resolution imaging through scattering medium thereby contributing to the development of biological and medical imaging technologies.Mechanical Engineerin

    Time-of-flight measurements of single-layer tissue with a chip-based optical frequency comb

    No full text
    Cerebral oxygen saturation is an important indicator that reflects the oxygen metabolism of the brain tissues in such patients. The utilization of near-infrared spectroscopy (NIRS) enables the identification of the oxygen saturation levels in nearby tissues by analyzing the distinct oxygenation states of hemoglobin-oxyhemoglobin (HbO2) and the distinctive molecular spectrum of deoxygenated hemoglobin (Hb). It is helpful to realize the objective of noninvasive continuous detection on cerebral oxygen saturation because near-infrared radiation can directly penetrate the skull to obtain the characteristics of the average oxygen saturation of the brain tissues. This also allows a noninvasive way to monitor blood flow in the brain. A frequency comb is a pulsed laser in the time domain and a sequence of discrete, uniformly spaced frequency lines in the frequency domain. Applying the frequency comb to NIRS has the potential to develop a high-speed and fs-level time-of-flight resolution blood flow measurement system. The objective of this thesis is to utilize a chip-based optical frequency comb as an illuminating source in order to conduct time-of-flight measurements of a single target, employing a Michelson interference experiment. The establishment of the time of flight in the single-layer case and the investigation of the non-ambiguity range form the fundamental basis for future experiments multi-layer.Mechanical Engineering | Micro-optics and Optomechatronic

    Spectroscopic photoacoustic imaging of radiofrequency ablation in the left atrium

    No full text
    Catheter-based radiofrequency ablation for atrial fibrillation has long-term success in 60-70% of cases. A better assessment of lesion quality, depth, and continuity could improve the procedure’s outcome. We investigate here photoacoustic contrast between ablated and healthy atrial-wall tissue in vitro in wavelengths spanning from 410 nm to 1000 nm. We studied single-and multi-wavelength imaging of ablation lesions and we demonstrate that a two-wavelength technique yields precise detection of lesions, achieving a diagnostic accuracy of 97%. We compare this with a best single-wavelength (640 nm) analysis that correctly identifies 82% of lesions. We discuss the origin of relevant spectroscopic features and perspectives for translation to clinical imaging.ImPhys/Acoustical Wavefield Imagin

    Photoacoustic imaging for guidance of interventions in cardiovascular medicine

    Get PDF
    Imaging guidance is paramount to procedural success in minimally invasive interventions. Catheter-based therapies are the standard of care in the treatment of many cardiac disorders, including coronary artery disease, structural heart disease and electrophysiological conditions. Many of these diseases are caused by, or effect, a change in vasculature or cardiac tissue composition, which can potentially be detected by photoacoustic imaging. This review summarizes the state of the art in photoacoustic imaging approaches that have been proposed for intervention guidance in cardiovascular care. All of these techniques are currently in the preclinical phase. We will conclude with an outlook towards clinical applications.ImPhys/Acoustical Wavefield Imagin

    Real-time volumetric lipid imaging in vivo by intravascular photoacoustics at 20 frames per second

    No full text
    Lipid deposition can be assessed with combined intravascular photoacoustic/ultrasound (IVPA/US) imaging. To date, the clinical translation of IVPA/US imaging has been stalled by a low imaging speed and catheter complexity. In this paper, we demonstrate imaging of lipid targets in swine coronary arteries in vivo, at a clinically useful frame rate of 20 s−1. We confirmed image contrast for atherosclerotic plaque in human samples ex vivo. The system is on a mobile platform and provides real-time data visualization during acquisition. We achieved an IVPA signal-to-noise ratio of 20 dB. These data show that clinical translation of IVPA is possible in principle.ChemE/Advanced Soft MatterImPhys/Acoustical Wavefield Imagin

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Get PDF
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
    corecore