1,720,994 research outputs found

    Two-colour X-gamma ray inverse Compton back-scattering source

    Full text link
    We present a simple and new scheme for producing two-colour Thomson/Compton radiation with the possibility of controlling separately the polarization of the two different colours, based on the interaction of one single electron beam with two light pulses that can come from the same laser setup or from two different lasers and that collide with the electrons at different angle. One of the most interesting cases for medical applications is to provide two X-ray pulses across the iodine K-edge at 33.2 keV. The iodine is used as contrast medium in various imaging techniques and the availability of two spectral lines accross the K-edge allows one to produce subtraction images with a great increase in accuracy

    Publisher’s Note: Analytical description of photon beam phase spaces in inverse Compton scattering sources [Phys. Rev. Accel. Beams 20, 080701 (2017)]

    Full text link
    This paper was published online on 3 August 2017 with an error in Eq. (20). Equation (20) should read as (Formula Prsented) The equation has been corrected online as of 14 September 2017

    Compton Scattered X-Gamma Rays with Orbital Momentum

    Full text link
    We study the possibility of producing x-gamma rays with orbital angular momentum by means of the inverse Compton backscattering between a high brightness electron beam and a twisted laser pulse. We use the classical electrodynamics retarded fields for evaluating the orbital angular momentum of the radiation and connecting it to that of the primary laser pulse. We then propose the dimensioning of a linearly polarized x-ray source with orbital angular momentum, starting from the parameters of operating Thomson setups

    Analytical description of photon beam phase spaces in inverse Compton scattering sources

    Full text link
    We revisit the description of inverse Compton scattering sources and the photon beams generated therein, emphasizing the behavior of their phase space density distributions and how they depend upon those of the two colliding beams of electrons and photons. The main objective is to provide practical formulas for bandwidth, spectral density, brilliance, which are valid in general for any value of the recoil factor, i.e. both in the Thomson regime of negligible electron recoil, and in the deep Compton recoil dominated region, which is of interest for gamma-gamma colliders and Compton sources for the production of multi-GeV photon beams. We adopt a description based on the center of mass reference system of the electron-photon collision, in order to underline the role of the electron recoil and how it controls the relativistic Doppler/boost effect in various regimes. Using the center of mass reference frame greatly simplifies the treatment, allowing us to derive simple formulas expressed in terms of rms momenta of the two colliding beams (emittance, energy spread, etc.) and the collimation angle in the laboratory system. Comparisons with Monte Carlo simulations of inverse Compton scattering in various scenarios are presented, showing very good agreement with the analytical formulas: in particular we find that the bandwidth dependence on the electron beam emittance, of paramount importance in Thomson regime, as it limits the amount of focusing imparted to the electron beam, becomes much less sensitive in deep Compton regime, allowing a stronger focusing of the electron beam to enhance luminosity without loss of mono-chromaticity. A similar effect occurs concerning the bandwidth dependence on the frequency spread of the incident photons: in deep recoil regime the bandwidth comes out to be much less dependent on the frequency spread. The set of formulas here derived are very helpful in designing inverse Compton sources in diverse regimes, giving a quite accurate first estimate in typical operational conditions for number of photons, bandwidth, spectral density and brilliance values—the typical figures of merit of such radiation sources

    ROSE : A numerical tool for the study of scattering events between photons and charged particles

    No full text
    We present the dimensioning of a photon–photon collider based on conventional Compton gamma sources for the observation of secondary cc production. Two symmetric electron beams in collision with two high energy lasers produce two primary gamma rays pulses through Compton back scattering. Tuning the energy of the system to the energy of the photon–photon cross section maximum, a flux of secondary gamma photons is generated. The Monte Carlo code ‘Rate Of Scattering Events’ (ROSE) has been developed adhoc for the counting of the QED events. The benchmark of the code for the Compton scattering process is presented. Realistic numbers of the secondary gamma yield, referring to existing or approved set-ups are presented

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Compensation of non-linear bandwidth broadening by laser chirping in Thomson sources

    Full text link
    A new laser chirping prescription is derived by means of the phase-stationary method for an incident Gaussian laser pulse in conjunction with a Lienard-Wiechert calculation of the scattered radiation flux and spectral brilliance. This particularly efficient laser chirp has been obtained using the electric field of the laser and for electrons and radiation on axis. The frequency modulation is somewhat reduced with respect to that proposed in the previous literature, allowing the application of this procedure to lasers with larger values of the parameter a(0). Numerical calculations have been performed using mildly focused and narrow bandwidth laser pulses, confirming a larger efficiency of the chirp prescription here introduced. The chirp efficiency has been analysed as a function of the laser parameter and focusing

    Inverse Compton radiation: a novel x-ray source for K-edge subtraction angiography?

    No full text
    Coronary angiography is clinically used worldwide to diagnose diseases of coronary arteries. Despite its effectiveness, this technique is quite invasive and it is associated with significant risks due to the arterial catheterisation needed to inject the contrast agent. A valid alternative is using the K-edge subtraction (KES) method, which is based on the subtraction of two images acquired at energies bracketing the K-edge of the contrast element. The enhanced sensitivity of KES allows the intravenous injection of the contrast agent, thus reducing the risks of catheterisation. This technique can be effectively implemented by using intense and quasi-monochromatic x-ray beams. Synchrotron radiation has been proven to work well for this purpose, but its cost and size prevent a widespread clinical application. Inverse Compton sources are among the most promising innovative sources of intense and quasi-monochromatic x-rays. These sources are intrinsically more compact than those based on synchrotron radiation. In this work, the potential application of inverse Compton radiation to KES angiography is investigated. To this purpose, after a short review of the physics behind the inverse Compton process, an analytical framework is described. The proposed model is based on the application of the KES algorithm to calculate the SNR of details inside a suitable mathematical phantom. That allowed us to identify the characteristics of an inverse Compton source required for KES imaging. In particular, it was estimated that a photon fluence of 108 ph mm-2 is necessary to detect signals of clinical interest. Novel sources based on inverse Compton promise to achieve this requirement with an acquisition time of few hundreds of ms. This feature, together with compactness, broad two-dimensional radiation field, absence of harmonic contamination and the ability to deliver high photon fluxes also at high energies, makes this kind of sources promising for KES angiography and other diagnostic applications

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
    corecore