345,139 research outputs found
Molecular structure of highly excited resonant states in Mg-24 and the corresponding Be-8+O-16 and C-12+C-12 decays
Exotic Be-8 and C-12 decays from high-lying resonances in Mg-24 are analyzed in terms of a cluster model. The calculated quantities agree well with the corresponding experimental data. It is found that the calculated decay widths are very sensitive to the angular momentum carried by the outgoing cluster. It is shown that this property makes cluster decay a powerful tool to determine the spin as well as the molecular structures of the resonances.Physics, NuclearSCI(E)7ARTICLE5null8
Mitomycin C in highly myopic eyes - Author reply
Ophthalmology. 2005 Feb;112(2):208-18; discussion 219.
Mitomycin C modulation of corneal wound healing after photorefractive keratectomy in highly myopic eyes.
Gambato C, Ghirlando A, Moretto E, Busato F, Midena E.
SourceRefractive Surgery Service and Antimetabolite Therapy Research Unit, Department of Ophthalmology, University of Padova, Padova, Italy.
Abstract
PURPOSE: To evaluate the role of topical mitomycin C in corneal wound healing (CWH) after photorefractive keratectomy (PRK) in highly myopic eyes.
DESIGN: Prospective, double-masked, randomized clinical trial.
PARTICIPANTS: Seventy-two eyes of 36 patients affected by high (>7 diopters) myopia.
METHODS: In each patient, one eye was randomly assigned to PRK with intraoperative topical 0.02% mitomycin C application, and the fellow eye was treated with a placebo. Postoperatively, mitomycin C-treated eyes received artificial tears (3 times daily, tapered in 3 months), whereas the fellow eye was treated with fluorometholone sodium 2% and artificial tears (3 times daily, tapered in 3 months).
MAIN OUTCOME MEASURES: Uncorrected visual acuity (UCVA) and best-corrected visual acuity (BCVA), contrast sensitivity, manifest refraction, and biomicroscopy. Contrast sensitivity was determined using the Pelli-Robson chart. Corneal confocal microscopy documented CWH.
RESULTS: Mean follow-up was 18 months (range, 12-36). No side effects or toxic effects were documented. At 12-month follow-up examination, UCVAs (logarithm of the minimum angle of resolution) were 0.4+/-0.48 and 0.5+/-0.53 (P = .03) in mitomycin C-treated eyes and corticosteroid-treated eyes, respectively. At 1 year, corneal haze developed in 20% of corticosteroid-treated eyes, versus 0% of mitomycin C-treated eyes. At 12, 24, and 36 months, corneal confocal microscopy showed activated keratocytes and extracellular matrix significantly more evident in untreated eyes (Ps = 0.004, 0.024, and 0.046, respectively).
CONCLUSION: Topical intraoperative application of 0.02% mitomycin C can reduce haze formation in highly myopic eyes undergoing PRK.
Comment in
Ophthalmology. 2006 Feb;113(2):357; author reply 357-8
B -> eta K-c(eta ' K-c) decays in QCD factorization
We study the exclusive decays of the B meson into pseudoscalar charmonium states eta(c) and eta(c)' within the QCD factorization approach and find that the non-factorizable corrections to naive factorization are infrared safe at leading-twist order. The spectator interactions arising from the kaon twist-3 effects are formally power suppressed but chirally and logarithmically enhanced. An important improvement by including the O(alpha(s)) corrections is the cancellation of the renormalization scale mu dependence of the decay amplitude. However, the calculated decay rates are too small to accommodate the experimental data. On the other hand, we compare the theoretical calculations for B meson decays to J/psi, psi', eta(c) and eta'(c), and find that the predicted relative decay rates of these four states are approximately compatible with the experimental data.http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000223097800007&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=8e1609b174ce4e31116a60747a720701Physics, Particles & FieldsSCI(E)17ARTICLE3365-3703
FIGURES 36–37 in Three new species of Coccobius Ratzeburg (Hymenoptera, Aphelinidae) and redescription of C. abdominis Huang and C. furviflagellatus Huang from China
FIGURES 36–37. Coccobius furviflagellatus, pupa: 36, dissected diaspidid scale showing a black female pupa (left) that has been hyperparasitized by a male, and a black male pupa (right) about to emerge as an adult; 37, exuviae of male.Published as part of Wang, Zhu-Hong, Huang, Jian & Polaszek, Andrew, 2014, Three new species of Coccobius Ratzeburg (Hymenoptera, Aphelinidae) and redescription of C. abdominis Huang and C. furviflagellatus Huang from China, pp. 460-472 in Zootaxa 3774 (5) on page 467, DOI: 10.11646/zootaxa.3774.5.4, http://zenodo.org/record/22456
FIGURES 57–58. Diaspidid scale associated with Coccobius leptocerus. 57 in Three new species of Coccobius Ratzeburg (Hymenoptera, Aphelinidae) and redescription of C. abdominis Huang and C. furviflagellatus Huang from China
FIGURES 57–58. Diaspidid scale associated with Coccobius leptocerus. 57, host diaspidid scale in leaf sheath of bamboo; 58, host mummy after C. leptoceras emergence.Published as part of Wang, Zhu-Hong, Huang, Jian & Polaszek, Andrew, 2014, Three new species of Coccobius Ratzeburg (Hymenoptera, Aphelinidae) and redescription of C. abdominis Huang and C. furviflagellatus Huang from China, pp. 460-472 in Zootaxa 3774 (5) on page 471, DOI: 10.11646/zootaxa.3774.5.4, http://zenodo.org/record/22456
History sketch 157th Engineer (C) Bn.
This is a historical description of the 157th Engineer (C) Battalion written from memory by author. Notes are not attached as described on last page of document
Tunable single and multiwavelength continuous-wave c-cut Nd:YVO <sub>4</sub> laser
We report a discretely tunable, single and multiwavelength continuous-wave diode-end-pumped laser with a c-cut Nd:YVO 4 crystal lasing on the 4F 3/2- 4I 11/2 intermanifold transitions and an intracavity sub-THz free-spectral-range etalon. Experimental results show that it is tunable in the discrete regions of 1066.5-1066.8, 1083.1-1084.6, and 1087.2-1088.2 nm and operates simultaneously at dual-wavelengths of (1084.6, 1087.4), (1066.5, 1088.0), (1066.8, 1083.3) nm by changing the angle of an intracavity etalon with 0.67 THz free-spectral range. With a proper etalon angle, the laser can also simultaneously oscillate at four wavelengths of 1066.9, 1082.9, 1085.7, and 1088.3 nm with a total output power of 1.2 W at an incident diode pump power of 15 W. Similar performance of the laser at different wavelengths was also achieved by using a 0.88 THz free-spectral-range etalon in the same laser cavity.</p
- …
