1,720,966 research outputs found

    Minimal-resection arthroplasty to treat meniscal tears with associated condyle lesions: finite element analysis

    No full text
    An early intervention prosthesis which minimizes the extent of resected healthy bone would be advantageous to patients for whom a total or unicompartmental replacement would sacrifice extensive healthy tissue. In this study the use of a device to treat osteoarthritis localized upon a single condyle of the femur with an associated irreparable meniscal tear is considered. The effects of implant alignment are considered from the standpoint of kinematics and potential for cartilage damage. The results suggest that alterations in implant position influence joint kinematics during stance. Anteroposterior (AP) adjustment of the medial prosthesis minimizes the capability of the knee to rotate internally, placing higher demands on the cruciate ligaments. AP adjustments of the lateral prosthesis induces greater posterior drawback, reducing internal—external rotation. Natural knee kinematics are best reproduced by the medial condyle rather than the lateral condyle. Stress exposure of the cartilage increased with the introduction of the femoral condyle prosthesis, which may progress eventually to osteoarthritis, although the results indicate that the medial condyle device is less likely to lead to cartilage damage than is lateral condyle replacement. This study demonstrates that a minimal-resection femoral condyle device may provide sufficient knee joint function to serve as an interim treatment prior to total or unicompartmental knee arthroplasty

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Finite element modelling of glenohumeral kinematics following total shoulder arthroplasty

    No full text
    Due to the shallowness of the glenohumeral joint, a challenging but essential requirement of a glenohumeral prosthesis is theprevention of joint dislocation. Weak glenoid bone stock and frequent dysfunction of the rotator cuff, both of which are common with rheumatoid arthritis, make it particularly difficult to achieve this design goal. Although a variety of prosthetic designs are commercially available only a few experimental studies have investigated the kinematics and dislocation characteristics of design variations. Analytical or numerical methods, which are predictive and more cost-effective, are, apart from simple rigid-body analyses, non-existent. The current investigation presents the results of a finite element analysis of the kinematics of a total shoulder joint validated using recently published experimental data for the same prostheses. The finite element model determined the loading required to dislocate the humeral head, and the corresponding translations, to within 4% of the experimental data. The finite element method compared dramatically better to the experimental data (mean difference = 2.9%) than did rigid-body predictions (mean difference = 37%).The goal of this study was to develop an accurate method that in future studies can be used for further investigations of the effect of design parameters on dislocation, particularly in the case of a dysfunctional rotator cuff. Inherently, the method also evaluates the glenoid fixation stresses in the relatively weak glenoid bone stock. Hence, design characteristics can be simultaneously optimised against dislocation as well as glenoid loosening

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Full text link
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Finite element analysis of uni-compartmental knee arthroplasty.

    No full text
    Concerns over accelerated damage to the untreated compartment of the knee following unicompartmental knee arthroplasty (UKA), as well as the relatively poor success rates observed for lateral as opposed to the medial arthroplasty, remain issues for attention. Finite element analysis (FEA) was used to assess changes to the kinematics and potential for cartilage damage across the knee joint in response to the implantation of the Oxford Mobile Bearing UKA. FE models of lateral and medial compartment arthroplasty were developed, in addition to a healthy natural knee model, to gauge changes incurred through the arthroplasty. Varus–valgus misalignments were introduced to the femoral components to simulate surgical inaccuracy or over-correction. Boundary conditions from the Stanmore knee simulator during the stance phase of level gait were used. AP translations of the tibia in the medial UKA models were comparable to the behaviour of the natural knee models (±0.6 mm deviation from pre-operative motion). Following lateral UKA, 4.1 mm additional posterior translation of the tibia was recorded than predicted for the natural knee. IE rotations of the medial UKA models were less consistent with the pre-operative knee model than the lateral UKA models (7.7° vs. 3.6° deviation). Varus misalignment of the femoral prosthesis was more influential than valgus for medial UKA kinematics, whereas in lateral UKA, a valgus misalignment of the femoral prosthesis was most influential on the kinematics. Resection of the cartilage in the medial compartment reduced the overall risk of progressive OA in the knee, whereas removing the cartilage from the lateral compartment, and in particular introducing a valgus femoral misalignment, increased the overall risk of progressive OA in the knee. Based on these results, under the conditions tested herein, both medial and lateral UKA can be said to induce kinematics of the knee which could be considered broadly comparable to those of the natural knee, and that even a 10° varus–valgus misalignment of the femoral component may not induce highly irregular kinematics. However, elevated posterior translation of the tibia in lateral UKA and large excursions of the insert may explain the higher incidence of bearing dislocation observed in some clinical studies
    corecore