1,720,990 research outputs found
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
Estimation of occlusion pressure during assisted ventilation in patients with intrinsic PEEP
We conducted a study to assess the validity of the occlusion pressure (P0.1) measured during activation of the trigger mechanism (P0.1(aw)trig) in patients showing variable levels of PEEPi during pressure-support ventilation. We first compared P0.1(aw)trig and P0.1 measured with the conventional method (i.e., the airway pressure drop after the first 100 ms of an occluded inspiration) in 16 patients with chronic obstructive pulmonary disease (COPD). We observed good agreement and a highly significant correlation (r = 0.99; bias = 0.3 +/- 0.5 cm H20) between the two methods. In a second part of the study, we compared, in 17 patients, P0.1(aw)trig with (P0.1(es)), measured as the depression generated on the esophageal pressure tracing in the first 100 ms of the inspiratory negative swing, and with P0.1 measured on the P(es) tracing simultaneously with P(aw)trig (P0.1(es-synchro)). Our results showed a good correlation and good agreement between P(aw)trig and P0.1(es) (r = 0.92; bias = 0.3 +/- 0.5 cm H20); P(aw)trig and P0.1(es-synchro) (r = 0.97; bias = 0.1 +/- 0.2 cm H20); and P0.1(es) and P0.1(es-synchro) (r = 0.95, bias = 0.2 +/- 0.4 cm H20), respectively. This study suggests that reliable measurements of inspiratory drive can be obtained easily, on a breath-by-breath basis, from airway pressure tracings during pressure-support ventilation in patients with variable levels of PEEPi
Gradual reduction of endotracheal tube diameter during mechanical ventilation via different humidification devices.
BACKGROUND:
Limited data suggest that increased resistance to flow within endotracheal tubes (ETT) may occur in patients whose lungs are mechanically ventilated for more than 48 h, especially when airway humidification is inadequate. This could lead to sudden ETT obstruction or induce excessive loading during spontaneous breathing.
METHODS:
Twenty-three such patients were randomly assigned to three types of airway humidifier based on three different working principles: a Fisher Paykell hot water system (n = 7), a Pall BB2215 heat and moisture exchanger (HME) hydrophobic filter (n = 8), and a Dar Hygrobac 35254111 HME hygroscopic filter (n = 8). The decrease in internal pressure along the ETT and the flow rate were measured in each patient every 2 days. An "effective inner diameter" was derived from these measurements and allowed the inner ETT configuration to be monitored.
RESULTS:
On the first day of intubation, the mean diameter was similar in the three groups, and was slightly smaller than the in vitro diameter (mean +/- SD: 7.6 +/- 0.6 mm for Fisher-Paykell, 7.7 +/- 0.4 for Pall, and 7.5 +/- 0.4 for Dar). The mean diameter tended to decrease from day to day. At the end of the study, the overall reduction in mean diameter was significantly greater with the hydrophobic HME (Pall) than with the two other systems (Pall: -6.5 +/- 4% vs. 2.5 +/- 2.5% for Dar and 1.5 +/- 3% for Fisher-Paykell; P < 0.01 with analysis of variance). The same was true of the mean reduction in effective inner ETT diameter expressed per day of ventilation (-1.6 +/- 1.5% per day for Pall vs. -0.5 +/- 0.4% for Dar and -0.2 +/- 0.4% for Fisher-Paykell; P < 0.01). In four patients, the ETT became obstructed and emergency repeated tracheal intubation was required. The Pall HME and the Fisher-Paykell system were being used in three and one patient, respectively. Before obstruction, the reduction in ETT diameter was significantly greater for these four patients than for the remaining 23 patients (7.8 +/- 1.4% vs. 3.1 +/- 4.1%; P < 0.01).
CONCLUSIONS:
During prolonged mechanical ventilation, significant alterations in inner ETT configuration occur frequently and are influenced by the type of humidification device used. In vivo monitoring of ETT mechanical properties might be clinically useful
koamabayili/VECTRON-author-checklist: VECTRON author checklist
We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
Effects of assisted ventilation on the work of breathing: volume-controlled versus pressure-controlled ventilation
During assisted ventilation, the same tidal volume can be delivered in different ways, with the possibility for the physician to vary the ventilatory target (pressure or volume) and the peak flow setting. We compared the effects on the respiratory work rate of assisted ventilation, delivered either with a square wave flow pattern (assist control ventilation [ACV]) or with a decelerating flow pattern and a constant pressure (assisted pressure-control ventilation [APCV]). In the first part of the study where seven patients were studied, inspiratory time and tidal volume were similar in the two modes of ventilation. High and moderate levels of tidal volume (VT) were studied (12 ml/kg and 8 ml/kg, respectively). To obtain moderate VT, inspiratory time was kept constant and, therefore, mean inspiratory flow was reduced. At high VT, no difference between ACV and APCV was noted for breathing pattern, respiratory drive indexes, respiratory muscle work, or arterial blood gases. All patients exhibited respiratory alkalosis. At moderate VT, normal pH was achieved. In this situation significantly lower levels were observed during APCV than during ACV for the power of breathing (10 +/- 2 versus 19 +/- 5 J/min, p<0.05), transdiaphragmatic pressure swing (7 +/- 1 versus 11 +/- 2 cm H2O, p<0.05), and pressure-time index (252 +/- 43 versus 484 +/- 114 cm H2O.s, p<0.05), even though breathing pattern and gas exchange were similar. In the second part of the study where six additional patients were studied, tidal volume was kept constant at a moderate level (8 ml/kg), and we studied the effect of shortening inspiratory time and increasing mean inspiratory flow. At moderate VT and high inspiratory flow, no significant differences could be found between ACV and APCV, and although pressure-time index tended to be lower during APCV, absolute levels of effort were of small magnitude (56 +/- 55 versus 76 +/- 55 cm H2O.s). We conclude that at moderate VT and low flow rates only, inspiratory assistance delivered at a constant pressure reduces the respiratory work rate more effectively than assist control ventilation
- …
