1,720,960 research outputs found

    Evaluation of Endotoxemia After Pediatric Cardiac Surgery With the Endotoxin Activity Assay: An Exploratory Prospective Cohort Study

    No full text
    Children with congenital heart diseases undergoing surgery with cardiopulmonary bypass are exposed to a high risk of perioperative endotoxemia. The aim of our study was to prospectively evaluate endotoxin assay activity reference levels during the postoperative phase of infants undergoing cardiac surgery for congenital heart disease and to assess their association with perioperative variables and postoperative infections

    Clinical Factors Associated with Dose of Loop Diuretics After Pediatric Cardiac Surgery: Post Hoc Analysis

    No full text
    A post hoc analysis of a randomized controlled trial comparing the clinical effects of furosemide and ethacrynic acid was conducted. Infants undergoing cardiac surgery with cardiopulmonary bypass were included in order to explore which clinical factors are associated with diuretic dose in infants with congenital heart disease. Overall, 67 patients with median (interquartile range) age of 48 (13–139) days were enrolled. Median diuretic dose was 0.34 (0.25–0.4) mg/kg/h at the end of postoperative day (POD) 0 and it significantly decreased (p = 0.04) over the following PODs; during this period, the ratio between urine output and diuretic dose increased significantly (p = 0.04). Age (r -0.26, p = 0.02), weight (r -0.28, p = 0.01), cross-clamp time (r 0.27, p = 0.03), administration of ethacrynic acid (OR 0.01, p = 0.03), and, at the end of POD0, creatinine levels (r 0.3, p = 0.009), renal near-infrared spectroscopy saturation (-0.44, p = 0.008), whole-blood neutrophil gelatinase associated lipocalin levels (r 0.30, p = 0.01), pH (r -0.26, p = 0.02), urinary volume (r -0.2755, p = 0.03), and fluid balance (r 0.2577, p = 0.0266) showed a significant association with diuretic dose. At multivariable logistic regression cross-clamp time (OR 1.007, p = 0.04), use of ethacrynic acid (OR 0.2, p = 0.01) and blood pH at the end of POD0 (OR 0.0001, p = 0.03) was independently associated with diuretic dose. Early resistance to loop diuretics continuous infusion is evident in post-cardiac surgery infants: Higher doses are administered to patients with lower urinary output. Independently associated variables with diuretic dose in our population appeared to be cross-clamping time, the administration of ethacrynic acid, and blood pH

    High levels of free haemoglobin in neonates and infants undergoing surgery on cardiopulmonary bypass

    No full text
    OBJECTIVES: Haemolysis is known to occur during surgery on cardiopulmonary bypass (CPB) and to be responsible for kidney injury. The aim of this study was to assess, in a cohort of infants, the reference levels of free haemoglobin (fHb) and their change over time postoperatively; the predicting variables of haemolysis in the intraoperative phase; and the association between fHb and renal function. METHODS: A retrospective analysis in infants undergoing surgery on CPB was conducted. Children with preoperative renal dysfunction and need for extracorporeal membrane oxygenation support were excluded. fHb was sampled before and after CPB and on the first 2 postoperative days (POD). RESULTS: Twenty-two patients with a median (interquartile) age of 111 (63-184) days and Aristotle score of 8 (6.4-9) were enrolled. fHb had a baseline value of 29 (24-41) mg/dl, peaked to 75 (65-109) mg/dl at CPB weaning and returned to 35 (30-55) mg/dl on POD 2 (P < 0.0001). The median normalized index of haemolysis was 0.15 (0.09-0.19) g of fHb per 100 l of pumped blood. A multivariable regression model showed that, at CPB weaning, fHb levels were independently associated with left atrial venting flow (P = 0.02), and that CPB time remained the only independent variable (P = 0.034), when left atrial venting was excluded from the analysis. Acute kidney injury (AKI) occurred in 10 patients (45%). fHb levels in the 48 post-CPB hours were not significantly different between AKI and non-AKI patients: However, a significant correlation was present between creatinine on POD1 and CPBw-fHb (r = 0.48; P = 0.045); and between cystatin C on POD1 and CPBw-fHb (r = 0.58; P = 0.02). CONCLUSIONS: A high rate of fHb is released during paediatric surgery with CPB in infants. fHb mainly depends on the left atrial venting flow rate and CPB duration. However, such peaks of fHb levels were not associated with renal dysfunctio

    Comparative evaluation of high-flow nasal cannula and conventional oxygen therapy in paediatric cardiac surgical patients: A randomized controlled trial

    No full text
    OBJECTIVES: The aim of this study was to compare high-flow nasal cannula (HFNC) and conventional O-2 therapy (OT) in paediatric cardiac surgical patients; the primary objective of the study was to evaluate whether HFNC was able to improve PaCO2 elimination in the first 48 h after extubation postoperatively. METHODS: We conducted a randomized, controlled trial in pediatric cardiac surgical patients under 18 months of age. At the beginning of the weaning of ventilation, patients were randomly assigned to either of the following groups: OT or HFNC. Arterial blood samples were collected before and after extubation at the following time points: 1, 6, 12, 24 and 48 h. The primary outcome was comparison of arterial PaCO2 postextubation; secondary outcomes were PaO2 and PaO2/fractional inspired oxygen (FiO(2)) ratio, rate of treatment failure and need of respiratory support, rate of extubation failure, rate of atelectasis, simply to complications and the length of paediatric cardiac intensive care unit stay. RESULTS: Demographic and clinical variables were comparable in the two groups. Analysis of variance for repeated measures showed that PaCO2 was not significantly different between the HFNC and OT groups (P = 0.5), whereas PaO2 and PaO2/FiO(2) were significantly improved in the HFNC group (P = 0.01 and P = 0.001). The rate of reintubation was not different in the two groups (P = 1.0), whereas the need for noninvasive respiratory support was 15% in the OT group and none in the HFNC group (P = 0.008). CONCLUSIONS: HFNC had no impact on PaCO2 values. The use of HFNC appeared to be safe and improved PaO2 in paediatric cardiac surgical patients

    Multisite Near Infrared Spectroscopy During Cardiopulmonary Bypass in Pediatric Patients

    No full text
    Multisite near infrared spectroscopy (NIRS) monitoring during pediatric cardiopulmonary bypass (CPB) has not been extensively validated. Although it might be rational to explore regional tissue saturation at different body sites (namely brain, kidney, upper body, lower body), conflicting results are currently provided by experience in children. The aim of our study was to evaluate absolute values of multisite NIRS saturation during CPB in a cohort of infants undergoing pediatric cardiac surgery to describe average differences between cerebral, renal, upper body (arm), and lower body (thigh) regional saturation. Furthermore, the correlation between cerebral NIRS and cardiac index (CI) at CPB weaning was evaluated. Twenty-five infants were enrolled: their median weight, age, and body surface area were 3.9 (3.3-6) kg, 111 (47-203) days, and 0.24 (0.22-0.33) m(2) , respectively. Median Aristotle score was 8 (6-10), and vasoactive inotropic score at CPB weaning was 16 (14-25). A total of 17 430 data points were recorded by each sensor: two-way ANOVA showed that time (P < 0.0001) and site (P = 0.0001) significantly affected variations of NIRS values: however, if cerebral NIRS values are excluded, sensor site is no more significant (P = 0.184 in the no circulatory arrest [noCA] group and P = 0.42 in the circulatory arrest [CA] group). Analysis of NIRS saturation changes over time showed that, at all sites, average NIRS values increased after CPB start, even if the increase of cerebral saturation was less intense than other sites (P < 0.0001). Detailed analysis of interaction between site of NIRS measurement and time point showed that cerebral NIRS (ranging from 65 to 75%) was always significantly lower than that of other channels (P < 0.0001) that tended to be in the range of oversaturation (80-90%), especially during the CPB phase. Average cerebral NIRS values of patients who did not undergo circulatory arrest (CA) during CPB, 10 min after CPB weaning, were associated with average CI values with a significant correlation (r = 0.7, P = 0.003). In conclusion, during CPB, cerebral NIRS values are expected to remain constantly lower than somatic sensors, which instead tend to show similar elevated saturations, regardless of their position. Based on these results, positioning of noncerebral NIRS sensors during CPB without CA may be questioned

    Pressure recording analytical method and bioreactance for stroke volume index monitoring during pediatric cardiac surgery

    No full text
    Background: It is currently uncertain which hemodynamic monitoring device reliably measures stroke volume and tracks cardiac output changes in pediatric cardiac surgery patients. Objective: To evaluate the difference between stroke volume index (SVI) measured by pressure recording analytical method (PRAM) and bioreactance and their ability to track changes after a therapeutic intervention. Methods: A single-center prospective observational cohort study in children undergoing cardiac surgery with cardiopulmonary bypass (CPB) was conducted. Twenty children below 20 kg with median (interquartile range) weight of 5.3 kg (4.1-7.8) and age of 6 months (3-20) were enrolled. Data were collected after anesthesia induction, at the end of CPB, before fluid administration and after fluid administration. Overall, median-IQR PRAM SVI values (23 ml.m(-2), 19-27) were significantly higher than bioreactance SVI (15 ml.m(-2), 12-25, P=0.0001). Correlation (r(2)) between the two methods was 0.15 (P=0.0003). The mean difference between the measurements (bias) was 5.7 ml.m(-2) with a standard deviation of 9.6 (95% limits of agreement ranged from -13 to 24 ml.m(-2)). Percentage error was 91.7%. Baseline SVI appeared to be similar, but PRAM SVI was systematically greater than bioreactance thereafter, with the highest gap after the fluid loading phase: 13 (12-18) ml.m(-2) vs. 23 (19-25) ml.m(-2), respectively, P=0.0013. A multivariable regression model showed that a significant independent inverse correlation with patients' body weight predicted the CI difference between the two methods after fluid challenge ( coefficient -0.12, P=0.013). Conclusions: Pressure recording analytical method and bioreactance provided similar SVI estimation at stable hemodynamic conditions, while bioreactance SVI values appeared significantly lower than PRAM at the end of CPB and after fluid replacement

    Furosemide versus ethacrynic acid in pediatric patients undergoing cardiac surgery: a randomized controlled trial

    No full text
    Clinical effects of furosemide (F) and ethacrynic acid (EA) continuous infusion on urine output (UO), fluid balance, and renal, cardiac, respiratory, and metabolic function were compared in infants undergoing surgery for congenital heart diseases

    Fiberoptic monitoring of central venous oxygen saturation (PediaSat) in small children undergoing cardiac surgery: continuous is not continuous [v2; ref status: indexed, http://f1000r.es/394]

    Full text link
    Background: Monitoring of superior vena cava saturation (ScvO2) has become routine in the management of pediatric patients undergoing cardiac surgery. The objective of our study was to evaluate the correlation between continuous ScvO2 by the application of a fiber-optic oximetry catheter (PediaSat) and intermittent ScvO2 by using standard blood gas measurements. These results were compared to those obtained by cerebral near infrared spectroscopy (cNIRS). Setting: Tertiary pediatric cardiac intensive care unit (PCICU). Methods and main results: A retrospective study was conducted in consecutive patients who were monitored with a 4.5 or 5.5 F PediaSat catheter into the right internal jugular vein. An in vivo calibration was performed once the patient was transferred to the PCICU and re-calibration took place every 24 hours thereafter. Each patient had a NIRS placed on the forehead. Saturations were collected every 4 hours until extubation. Ten patients with a median age of 2.2 (0.13-8.5) years and a weight of 12.4 (3.9-24) kg were enrolled. Median sampling time was 32 (19-44) hours: 64 pairs of PediaSat and ScVO2 saturations showed a poor correlation (r=0.62, 95% CI 44-75; p<0.0001) and Bland Altman analysis for repeated measures showed an average difference of 0.34 with a standard deviation of 7,9 and 95% limits of agreement from -15 to 16. Thirty-six pairs of cNIRS and ScVO2 saturations showed a fair correlation (r=0.79, 95% CI 0.60-0.89; p<0.0001) an average difference of -1.4 with a standard deviation of 6 and 95% limits of agreement from -13 to 10. Analysis of median percentage differences between PediaSat and ScvO2 saturation over time revealed that, although not statistically significant, the change in percentage saturation differences was clinically relevant after the 8th hour from calibration (from -100 to +100%). Conclusion: PediaSat catheters showed unreliable performance in our cohort. It should be further investigated whether repeating calibrations every 8 hours may improve the accuracy of this system. CNIRS may provide similar results with a lower invasiveness

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
    corecore