1,721,020 research outputs found

    Radiofrequency coils for magnetic resonance applications: Theory, design, and evaluation

    No full text
    Magnetic resonance imaging and magnetic resonance spectroscopy are noninvasive diagnostic techniques based on the phenomenon of nuclear magnetic resonance. Radiofrequency coils are key components in both the transmission and receiving phases of magnetic resonance systems. Transmitter coils have to produce a highly homogeneous alternating field in a wide field of view, whereas receiver coils have to maximize signal detection while minimizing noise. Development of modern magnetic resonance coils often is based on numerical methods for simulating and predicting coil performance. Numerical methods allows the behavior of the coil in the presence of realistic loads to be simulated and the coil’s efficiency at high magnetic fields to be investigated. After being built, coils have to be characterized in the laboratory to optimize their setting and performance by extracting several quality indices. Successively, coils performance has to be evaluated in a scanner using standardized image quality parameters with phantom and human experiments. This article reviews the principles of radiofrequency coils, coil performance parameters, and their estimation methods using simulations, workbench, and magnetic resonance experiments. Finally, an overview of future developments in radiofrequency coils technology is included

    Systematic Review of fMRI Compatible Devices: Design and Testing Criteria

    No full text
    Functional Magnetic Resonance Imaging (fMRI) is at present one of the most used methodologies for functional brain exploration, both in clinical and research settings. fMRI can noninvasively measure neural activity by using specific experimental paradigms. Often, these paradigms require the stimulation of the subject to perform sensorimotor tasks: in the past, the stimuli have been administered manually for investigating fundamental aspects of tactile perception and somatosensory processing. Nowadays, the use of mechatronic devices to stimulate the subject during fMRI studies is growing, also to assure reproducibility, control, and monitoring of task performances. For these reasons, researchers are interested in designing interfaces to be used inside the MRI environment during fMRI studies. For the design of every new device safety and compatibility constraints, imposed by the presence of high static magnetic field, switching magnetic gradients and radiofrequency electromagnetic pulses, must be satisfied. Moreover, it should be considered that functional imaging sequences are even more sensitive to perturbations of the magnetic field than MRI standard diagnostic sequences. Despite several existing devices for use in fMRI studies, an extensive review is still lacking. Our survey aims to introduce into the challenges imposed on the development of fMRI-compatible devices. The current state of the art of compatible devices in fMRI will be presented, pointing out the functionalities and peculiarities of various kinds of device. A particular emphasis will be placed on the tests for the evaluation of fMRI compatibility. This review will be useful both for designers of devices to be used in fMRI studies and for neuroscientists that are having to design fMRI experimental paradigm, and therefore require an overview of existing instruments, but also a knowledge of the benefits and criticism arising from their use

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Numerical evaluation of human exposure to WiMax patch antenna in tablet or laptop

    No full text
    The use of wireless communication devices, such as tablets or laptops, is increasing among children. Only a few studies assess specific energy absorption rate (SAR) due to exposure from wireless-enabled tablets and laptops, in particular with Worldwide Interoperability for Microwave Access (WiMax) technology. This paper reports the estimation of the interaction between an E-shaped patch antenna (3.5 GHz) and human models, by means of finite-difference time-domain (FDTD) method. Specifically, four different human models (young adult male, young adult female, pre-teenager female, male child) in different exposure conditions (antenna at different distances from the human model, in different positions, and orientations) were considered and whole-body, 10 and 1 g local SAR and magnetic field value (Bmax) were evaluated. From our results, in some worst-case scenarios involving male and female children's exposure, the maximum radiofrequency energy absorption (hot spots) is located in more sensitive organs such as eye, genitals, and breast. Bioelectromagnetics. 39:414–422, 2018. © 2018 Wiley Periodicals, Inc

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Full text link
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Sviluppo di un tool per stima dell'esposizione professionale a campi elettromagnetici in risonanza magnetica

    No full text
    La Risonanza Magnetica (RM) è una tecnica diagnostica largamente utilizzata in diversi campi della medicina e per il suo corretto funzionamento ricorre a diverse tipologie di campi elettromagnetici (EM). Lo staff RM durante il lavoro giornaliero è esposto in maniera prolungata al campo magnetico statico e spazialmente eterogeneo presente in ogni momento nella sala RM. Muovendosi all’interno della stanza RM per espletare le loro funzioni, i tecnici sono esposti a campo magnetico variabile lentamente nel tempo che induce correnti elettriche nel corpo. Nonostante non ci siano ancora conferme sui possibili effetti nocivi sulla salute umana di questa corrente indotta [1], la Comunità Europea (CE) ha redatto una Direttiva (Direttiva 2004/40/EC) [2] nella quale si pone un limite di sicurezza a questa corrente. Tale Direttiva dovrà essere recepita da tutti gli stati membri entro aprile 2012. L’utilizzo di modelli matematici e di simulazioni al calcolatore permette di stimare la corrente indotta e di avere quindi informazioni importanti sull’esposizione degli operatori durante il turno giornaliero e in diverse condizioni operative. In questo lavoro viene presentato un nuovo strumento per la stima della densità di corrente indotta a causa dei movimenti dei lavoratori nel campo magnetico statico di uno scanner MR. Il tool rappresenta un valido strumento per rivelare situazioni in cui i limiti di esposizione della direttiva possono essere superati, consentendo di addestrare gli operatori ad evitare, per quanto possibile, comportamenti a rischio di alta esposizione

    Electrophysiological patterns and structural substrates of Brugada syndrome: Critical appraisal and computational analyses

    No full text
    : Brugada syndrome (BrS) is a cardiac electrophysiological disease with unknown etiology, associated with sudden cardiac death. Symptomatic patients are treated with implanted cardiac defibrillator, but no risk stratification strategy is effective in patients that are at low to medium arrhythmic risk. Cardiac computational modeling is an emerging tool that can be used to verify the hypotheses of pathogenesis and inspire new risk stratification strategies. However, to obtain reliable results computational models must be validated with consistent experimental data. We reviewed the main electrophysiological and structural variables from BrS clinical studies to assess which data could be used to validate a computational approach. Activation delay in the epicardial right ventricular outflow tract is a consistent finding, as well as increased fibrosis and subclinical alterations of right ventricular functional and morphological parameters. The comparison between other electrophysiological variables is hindered by methodological differences between studies, which we commented. We conclude by presenting a recent theory unifying electrophysiological and structural substrate in BrS and illustrate how computational modeling could help translation to risk stratification
    corecore