1,720,958 research outputs found
The “Sombrero-Shape” Super-Thin Pedicled ALT Flap for Complete Scrotal Reconstruction Following Fournier’s Gangrene
When the scrotal sac is entirely debrided following a Fournier gangrene, testes exposure poses unique challenges for the reconstructive surgeon. Despite the anterolateral thigh (ALT) flap is considered a workhorse in such context, aesthetic results are often suboptimal because of the lack of natural ptosis and patchwork appearance. We describe the use of a super-thin pedicled ALT flap for total scrotal reconstruction, modified according to a peculiar flap design and inset technique. A 42-year-old man was referred to our department for delayed total scrotal reconstruction 8 months after a Fournier gangrene extensive debridement. A super-thin pedicled ALT flap from the right thigh was designed: in the central portion of the ALT, a lateral skin paddle extension was marked to guarantee adequate posterior anchorage during insetting and ptosis of the scrotal sac. This particular flap arrangement has inspired the name “sombrero” as the shape is akin to the famous hat. No secondary refinements were needed, and the patient showed satisfying aesthetic and functional results at 12 months’ follow-up. The ALT flap design “sombrero” modification proposed in this article can improve scrotum cosmesis and patient satisfaction in a single-stage single-flap procedure
Synthetic simulators for microsurgery training: a systematic review
Background: Microsurgery has a steep learning curve. Synthetic simulators have proven to be useful training tools for the initial learning stages, as well as being ethically sound, viable, safe, and cost-effective. The objective of this review was to determine the quality, effectiveness, and validity of these simulators as well as to assess their ability to evaluate microsurgical skills.
Methods: A systematic review following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines was performed. We searched databases (Web of Science, Scopus, and PubMed) to identify original articles describing synthetic training models for microsurgery. Three reviewers evaluated articles for inclusion following predefined selection criteria. Data were extracted from full-texts of included articles.
Results: Thirty-nine studies met the inclusion criteria. A total of 38 different devices have been recorded. Microsurgical training devices offer a low-cost, fast, and consistent method to concretely quantify and assess the initial microsurgical skills of trainees using standardized exercises that can be scored by the examiner. According to the authors, the outcomes were satisfactory, with a tangible improvement in microsurgical abilities, despite the lack of a common comparison scale.
Conclusions: Thanks to their availability, cost, and effectiveness, synthetic models are the recommended option to train basic, intermediate and advanced procedures before executing them on in vivo models
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
koamabayili/VECTRON-author-checklist: VECTRON author checklist
We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
Author-wise bibliometric analysis based on entropy.
Author-wise bibliometric analysis based on entropy.</p
- …
