    Dynamic Building Envelope Components and nearly Zero Energy Buildings

    No full text
    Due to the significant impact of the building sector on greenhouse gas emissions, newer and stricter regulations aimed at reducing total energy use in buildings have appeared in the last few years. In the European context, all the new constructions will thus soon be asked to be nearly Zero Energy Buildings (nZEB). In order to reach this target, new concepts and technologies capable of further improving buildings' energy efficiency need to be developed. A very promising strategy to overcome current technologylimitations is represented by revisiting the conventional approach that considers the building as a staticobject and moves towards the vision where the building is a responsive and dynamic system. The main feature of this concept is the possibility of continuously changingthe interaction between the building elementsand the outdoor/indoor environment in order to reduce the energy demands and enhance the exploitation of "environmental" and low-exergy energies. In this framework, the building skin isprobably that element of the construction which shows the largest potential, especially if its properties can be continuously tuned so that the best response to different dynamic indoor and outdoor boundary conditions can be achieved. Although it is not possible to state that the dynamic building envelope alone could represent the only solution to achieving the nZEB target, great expectations are placed on advanced integrated façade systems. The aim of this research is therefore to evaluate to what extent dynamic and active building skins can reduce operational energy demand in buildings. In order to find an answer to such a wide (and general) question, the research activity is organized using a multi-level structure. Each segment of the investigation is thus dedicated to assessing the impact of such a vision on different scales: from a whole building skin approach (concept level) to an intermediate scale (system level) and further down to a very detailed and specific class of components (material-technology level). In the concept level, an ideal dynamic building skin is assumed and modelled. The performance of such a theoretical configuration is then numerically assessed and compared with that of a more conventional reference envelope solution. In the system level, an integrated multifunctional façade module, characterized by a high degree of adaptability and responsiveness, is presented, and its energy and thermo-physical behaviour evaluated by means of an experimental analysis. Finally, in the material-technology level, the implication of glazing systems integrating phase change materials on the energy performance and on thermal comfort are evaluated by means of experimental, numerical and laboratory analyses. The findings demonstrate that improvements in energy efficiency and comfort performance can be achieved when dynamic concepts, systems and technologies are applied. In every level, the dynamic component often provides a very good performance and, when compared to a conventional solution, advantages are shown.However, it is important that dynamic components are coherently employed in the framework of an integrated building design vision and properly managed. Further, the simple adoption of such systems without a global approach and optimal control strategies is often not enough to reach a significant improvement in energy efficiency and IEQ. The results also show that, sometimes, the advantages achieved by the investigated configurations may be lower than expected, though an optimization of their performance is probably still possible. Limitations in the analyses and possible solutions for future development of the research activity are also discussed, pointing out that, if from the one hand, considerable efforts are still needed in research and development before a completely adaptable building skin can be effectively employed on a large scale, on the other hand the large potentials that this vision has are worthy of further investigatio

    Thermo-physical behaviour and energy performance assessment of PCM glazing system configurations: A numerical analysis

    Get PDF
    AbstractThe adoption of Phase Change Materials (PCMs) in glazing systems was proposed to increase the heat capacity of the fenestration, being some PCMs partially transparent to visible radiation.The aim of the PCM glazing concept was to let (part) of the visible spectrum of the solar radiation enter the indoor environment, providing daylighting, while absorbing (the largest part of) the infrared radiation.In this paper, the influence of the PCM glazing configuration is investigated by means of numerical simulations carried out with a validated numerical model. Various triple glazing configurations, where one of the two cavities is filled with a PCM, are simulated, and PCM melting temperatures are investigated. The investigation is carried out in a humid subtropical climate (Cfa according to Köppen climate classifi-cation), and “typical days” for each season are used.The results show that the position of the PCM layer (inside the outer or the inner cavity) has a relevant influence on the thermo-physical behaviour of the PCM glazing system. PCM glazing systems (especially those with the PCM layer inside the outermost cavity) can be beneficial in terms of thermal comfort. The assessment of the energy performance and efficiency is instead more complex and sometimes controversial. All the configurations are able to reduce the solar gain during the daytime, but sometimes the behaviour of the PCM glazing is less efficient than the reference one

    Building Performance Simulation and Characterization of Adaptive Facades – Adaptive Facade Network

    No full text
    The book “Performance Simulation and Characterisation of Adaptive Facades” responds to the need of providing a general framework, standardised and recognised methods and tools to evaluate the performance of adaptive facades in a quantitative way, by means of numerical and experimental methods, in different domains of interest. This book represents the main outcome of the activities of the Working Group 2 of the COST Action TU1403 Adaptive Façades Network, “Components performance and characterisation methods”, by integrating in one publication the main deliverables of WG2 described in the Memorandum of Understanding: D 2.1. Report on current adaptive facades modelling techniques; D 2.4. Report on the validation of developed simulation tools and models; D 2.5. Report on the developed experimental procedures. These are extended by additional sections regarding structural aspects and key performance indicators for adaptive façade systems. This book is a comprehensive review of different areas of research on adaptive façade systems and provides both general and specific knowledge about numerical and experimental research methods in this field. The fast pace at which building technologies and materials develop, is slowly but constantly followed by the development of numerical and experimental methods and tools to quantify their performance. Therefore this book focuses primarily on general methods and requirements, in an attempt to provide a coherent picture of current and near future possibilities to simulate and characterise the performance of adaptive facades in different domains, which could remain relevant in the coming years. In addition, specific know-how on selected cases is also presented, as a way to clarify and apply the more general approaches and methods described. The present book is published to support practitioners, researchers and students who are interested in designing, researching, and integrating adaptive façade systems in buildings. It targets both the academic and the not-academic sectors, and intends to contribute positively to an increased market penetration of adaptive façade systems, components and materials, aimed at rationalising energy and material resources while achieving a high standard of indoor environmental quality, health and safety in the built environment

    Analysis of a non-calorimetric method for assessment of in-situ thermal transmittance and solar factor of glazed systems

    Get PDF
    The performance of glazing systems is usually assessed through the thermal transmittance and the solar factor, two metrics characterised either through calorimetric laboratory tests or calculations. In this paper, the analysis of the performance of a non-calorimetric method for obtaining the in-situ thermal transmittance and solar factor of glazing systems is presented. This method, developed as a trade-off between accurate (and expensive) laboratory tests (which characterise the systems under standardised, “averaged” conditions), and easy and less expensive tests on systems installed in real buildings (under real operative conditions), has been previously adopted for the characterisation of different glazed systems, but never presented and discussed in full detail. The method, suitable for full-scale glazing systems installed in buildings or in test cells, is based on the acquisition of temperature, heat flux, and solar irradiance values. Experimental data are then processed through simple equations and linear regressions to determine the thermal transmittance and the solar factor under real boundary conditions. In this paper, a detailed description of the method, the experimental test rig, and the related expected accuracy is reported. The method is then applied to a case study (a conventional double glazed unit) to give an example of the proposed procedure and to validate it. The results of the case study show the capability of the assessed in-situ thermal transmittance and solar factor to replicate the thermophysical behaviour of the glazing system within a satisfactory degree of accuracy. An in-depth discussion on the observed outcomes from the case study deepens the understanding of the method’s performance and the results’ significance

    Structural Characterisation and Performance Assessment

    No full text
    Modern adaptive facades can significantly improve energy and thus cost, efficiency of both new and refurbished buildings by responding to the changes in the outdoor conditions. Furthermore, they can provide healthy and comfortable indoor environment to the building occupants, by adjusting the response to their needs. As the main function of facades is to separate the indoor from the outdoor environment, their performance has a major impact to the building’s energy usage is extremely important for reaching the European Commission’s ambitious climate and energy targets by 2020, as well as to follow the 2050 energy roadmap goals. However, another important function of facades is to transfer various design loads (to the building skeleton) and to accommodate movements due to the same actions, being characterized by different features as in the case of self-weight, wind, earthquake loads, as well as thermal actions, extreme mechanical loads, etc. Depending on the type and level of adaptivity of a given facade, such a structural demand could lead to challenges during the overall design process. On the other hand, structural adaptivity can lead to a more efficient static and dynamic response under varying loading conditions, i.e. increase resistance in case of extreme events and/or provide fail-safe collapse mechanisms, thereby enhancing structural robustness. This document collects some major outcomes and feedback from the “Structural” Task Group within the WG2 - COST Action TU1403

    Experimental analysis of the energy performance of a full-scale PCM glazing prototype

    No full text
    This paper deals with the development and use of innovative glazing systems that utilize Phase Change Material (PCM) to achieve dynamic and responsive behaviour. The coupling of a PCM and glass panes could be a way of improving the low thermal inertia of fenestrations and could be an effective way of collecting, storing and exploiting solar energy at a building scale. In the present work, a simple prototype of a PCM glazing system has been proposed and its energy performance has been analysed and compared with a conventional fenestration. The two glazing technologies were installed on an south facing outdoor test cell, in a temperate sub-continental climate. The surface temperatures, transmitted irradiances and heat fluxes of both the PCM glazing and the reference fenestration were measured during an extensive experimental campaign. Summer, Mid-season and Winter days were considered during the analysis, in both sunny and cloudy weather conditions, in order to assess the energy performance of the PCM glazing under different boundary conditions. The experimental results have highlighted a good ability of the PCM glazing to store solar energy and to smooth and delay peak values of the total heat flux. In summer the PCM prototype allows the energy gain to be lowered by more than 50%, compared to the traditional fenestration. In winter, a suitable reduction in the heat loss during the day can be observed, but the direct solar gain is also drastically reduced and the application of this technology for passive solar heating purpose might not always be effective. The obtained results have pointed out the promising performance of PCM glazing, even though a careful integration of the PCM glazing component with the control strategies of the indoor air temperature (e.g. night cooling) is necessar

    Improving thermal comfort conditions by means of PCM glazing systems

    No full text
    The adoption of phase change materials (PCMs) in glazing can represent a way of improving the low thermal inertia of transparent envelope components. PCM allows the internal surface temperatures of the glazing to be controlled, and this could improve the energy efficiency and thermal comfort performance of a facade. In the present work, a prototype of a simple PCM glazing system is proposed and its behaviour is compared with that of a conventional reference double glazed unit. The surface temperatures and the transmitted irradiances of the PCM glazing prototype and of a reference fenestration, measured over a six-month experimental campaign, have been used to numerically evaluate the indoor thermal conditions inside a typical office room. Different boundary conditions, ranging from summer to winter season, including the mid-season, have been analysed. The results concerning thermal comfort are illustrated and discussed in this work and the glazing prototype, the experimental set-up and the measurement methods are presented. The obtained results demonstrate the promising performance of the PCM glaizing system, which is able to contribute to the attainment of a better indoor thermal environmen

    Energy performance assessment of advanced glazed façades in office buildings

    No full text
    The adoption of glazed façades in commercial building is becoming more and more widespread. The main limits of conventional transparent façades related to energy efficiency and IEQ aspects have been overcome developing a new generation of transparent building envelope components called Advanced Integrated Façades This paper evaluates if the thermal behaviour of this kind of technologies can be correctly assessed by means of conventional performance parameters. Data from experimental campaigns on a reflective double glazed unit and on a Climate Façade under actual operating conditions have been used to estimate the correspondent equivalent U-value and g-value. Subsequently, these parameters have been employed to calculate the energy balance of the same glazed façades. The validation of the parameters is then carried out through the comparison between experimental and simulated specific total hourly heat flux and specific total daily energy. The result shows that it is still acceptable to use conventional performance parameters for “simple” glazing technology (e.g. reflective double glazing unit). On the contrary, the adoption of such parameters in case of more advanced façade technologies leads to considerable inaccuracies and makes the predictions based on these metrics not reliable

    A numerical model to evaluate the thermal behaviour of PCM glazing systems

    No full text
    The adoption of Phase Change Materials (PCMs) in building components is an up-to-date topic and a relevant number of research activities on this issue are currently on the way. A particular application of PCMs in the building envelope focuses on the integration of such a kind of material into transparent envelope components. A numerical model that describes the thermo-physical behaviour of a PCM layer in combination with other transparent materials (i.e. glass panes) has been developed to perform numerical analyses on various PCM glazing systems configurations. The paper illustrates the structure of the model, the main equations implemented and the hypotheses adopted for the model development. The comparison between numerical simulations and experimental data of a simple PCM glazing configuration is also presented to show the potentials and the limitations of the numerical model. While a good agreement between simulations and experimental data can be shown for the surface temperature of the glazing, the comparison between simulated and measured transmitted irradiances and heat fluxes does not always reach the desired accuracy. However, the numerical tool seems to predict well the thermo-physical behaviour of the system and may therefore represent a good starting point for further simulations on PCM glazing system configurations