1,720,954 research outputs found
Post-orthodontic recontouring using the Injection Resin Technique.
Aim: to present a versatile, rapid and effective technique for post-orthodontic recontouring of lateral upper incisors using flowable composite and a PVS matrix.
Methods: a 15-years old female patient presented at the end of the orthodontic treatment with microdontia of the lateral upper incisors. The integrity of the enamel suggested a minimally invasive adhesive technique with a “no prep” approach and the “Injection Resin Technique” was chosen. Alginate impressions of both arches were recorded for the realization of the diagno- stic wax-up. A clear PVS impression material was used to replicate the wax-up, thus obtaining a clear matrix and two small openings were made to allow insertion of the composite tip.The unprepared teeth were submitted to the adhesive protocol, the clear matrix was positioned and an A2-shade flowable resin composite was injected in a controlled manner, taking care to avoid bubbles formation. The resin was light-cured through the PVS matrix for 2 minutes, then without it for 2 more minutes. Composite excesses were removed using a #12 scalpel blade and the restorations were finished and polished.
Results: one week after treatment, the patient was called back for a subsequent polishing session and was extremely satisfied with the treatment.
Conclusion: sst and minimally invasive solution to complete the aesthetic result of the orthodontic treatment
Influence of sealer placement technique and powder/liquid mixing ratio on the quality of single cone root canal filling: a micro-CT analysis
Aim: To assess the influence of two different placement techniques and powder/liquid mixing ratio of a bioceramic sealer on the quality of root canal filling by single-cone using a micro-CT analysis.
Methods: Thirty-two single-rooted elements with a mesio-distal diameter of 5,00±0,50 mm, a buccallingual diameter of 6,50 ±0,50 mm and a root length of 14,50±0,50 mm measured at CEJ level were selected to be included in the study. After creating the coronal access cavity, root canals were scouted with manual files and the working length was acquired. Root canals were shaped with R40 Reciproc Blue and irrigated with NaOCl 5% and EDTA 17% solutions. Prepared samples were randomly assigned into four experimental groups (n=8), according to the sealer placement technique and the powder/liquid mixing ratio: G1, the sealer (BioRoot RCS, Septodont) was mixed in a 1:5 ratio, as suggested by the manufacturer, and carried into the root canal by a dedicated gutta-percha cone up to the working length; G2, sealer placement as group G1, but using 1:6 mixing ratio; G3, the sealer was mixed in a 1:5 ratio and carried into the root canal by a syringe with a cannula (Apexcal, Ivoclar) up to its complete filling, then a dedicated gutta-percha cone was inserted into the canal; G4, sealer placement as group G3, but using 1:6 mixing ratio. All the samples were submitted to micro-CT analysis. Micro-CT scans were acquired after shaping procedures (t0) and after canals obturation (t1) and then compared to evaluate the presence of voids in the gutta-percha, sealer and dentin interfaces. The normality of the distribution and the equality of variance of the microtomographic datasets were tested with a Shapiro-Wilk and Levene test, respectively; the significance of the differences between groups in terms of the formation of voids was ascertained with the Kruskal-Wallis test. The results were considered statistically significant for a p-value < 0.05.
Results: Minimal void volumes were observed among groups. G1 performed the best result: total void volumes were 0,253±0,175% of the entire canal space. The other experimental groups follow in order of increasing volume: G3 (0,260±0,254%), G2 (0,532±0,528%), G4 (0,840±0,705%), but no statistically significant difference was observed. All groups showed a similar distribution of voids: in the apical and middle third of the root canal the presence of voids was minimal while the greatest void volumes were detected in the coronal third, due to the canal anatomy and the larger amount of sealer. In this canal portion voids were mainly distributed within the sealer. Concerning the sealer viscosity, the more fluid formulation (1:6) showed an increase of void volumes, although without statistical significance. Likewise, no statistically relevant influence was registered regarding the sealer placement technique.
Conclusion: All the examined techniques should be considered effective for the clinician. Under the conditions of the present study, the 1:5 powder/liquid mixing ratio should be preferred when associated with both the sealer placement techniques, according to the clinical situation and the operator preferences. When using the low viscosity formulation, the clinician should insert the sealer slowly and in a controlled way, in order to minimize the formation of voids
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
koamabayili/VECTRON-author-checklist: VECTRON author checklist
We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
Author-wise bibliometric analysis based on entropy.
Author-wise bibliometric analysis based on entropy.</p
- …
