169,747 research outputs found
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Mitomycin C in highly myopic eyes - Author reply
Ophthalmology. 2005 Feb;112(2):208-18; discussion 219.
Mitomycin C modulation of corneal wound healing after photorefractive keratectomy in highly myopic eyes.
Gambato C, Ghirlando A, Moretto E, Busato F, Midena E.
SourceRefractive Surgery Service and Antimetabolite Therapy Research Unit, Department of Ophthalmology, University of Padova, Padova, Italy.
Abstract
PURPOSE: To evaluate the role of topical mitomycin C in corneal wound healing (CWH) after photorefractive keratectomy (PRK) in highly myopic eyes.
DESIGN: Prospective, double-masked, randomized clinical trial.
PARTICIPANTS: Seventy-two eyes of 36 patients affected by high (>7 diopters) myopia.
METHODS: In each patient, one eye was randomly assigned to PRK with intraoperative topical 0.02% mitomycin C application, and the fellow eye was treated with a placebo. Postoperatively, mitomycin C-treated eyes received artificial tears (3 times daily, tapered in 3 months), whereas the fellow eye was treated with fluorometholone sodium 2% and artificial tears (3 times daily, tapered in 3 months).
MAIN OUTCOME MEASURES: Uncorrected visual acuity (UCVA) and best-corrected visual acuity (BCVA), contrast sensitivity, manifest refraction, and biomicroscopy. Contrast sensitivity was determined using the Pelli-Robson chart. Corneal confocal microscopy documented CWH.
RESULTS: Mean follow-up was 18 months (range, 12-36). No side effects or toxic effects were documented. At 12-month follow-up examination, UCVAs (logarithm of the minimum angle of resolution) were 0.4+/-0.48 and 0.5+/-0.53 (P = .03) in mitomycin C-treated eyes and corticosteroid-treated eyes, respectively. At 1 year, corneal haze developed in 20% of corticosteroid-treated eyes, versus 0% of mitomycin C-treated eyes. At 12, 24, and 36 months, corneal confocal microscopy showed activated keratocytes and extracellular matrix significantly more evident in untreated eyes (Ps = 0.004, 0.024, and 0.046, respectively).
CONCLUSION: Topical intraoperative application of 0.02% mitomycin C can reduce haze formation in highly myopic eyes undergoing PRK.
Comment in
Ophthalmology. 2006 Feb;113(2):357; author reply 357-8
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
Accuracy of continuous thermodilution cardiac output by pulmonary artery catheter during therapeutic hypothermia in post-cardiac arrest patients
Accuracy of continuous thermodilution cardiac output by pulmonary artery catheter during therapeutic hypothermia in post-cardiac arrest patients
A Multi-Language Comparison of Influences on Author Verification using Character N-Grams
We create a new multi-language corpus for author verification based on Wikipedia talkpages, and evaluate the influence that differences in topic and time have on character n-gram author profiles. Topic alignment between two texts is found to increase author verification precision, and an authors writing style is found to change over time, but not more significantly after 3 years than after 1 year.Information ArchitectureWISElectrical Engineering, Mathematics and Computer Scienc
A 0.12mm<sup>2</sup> Wien-Bridge Temperature Sensor with 0.1°C (3σ) Inaccuracy from -40°C to 180°C
Resistor-based temperature sensors can achieve much higher resolution and energy efficiency than conventional BJT-based sensors [1], but they typically occupy more area (> 0.25 mm 2 ) and have lower operating temperatures (le 125 {circ} {C}) [2]-[4]. This work describes a 0.12mm 2 resistor-based sensor that uses a Wien-bridge (WB) filter to achieve 0.1 {circ} {C} (3 sigma) inaccuracy from - 40 {circ} {C} to 180 {circ} {C}. Compared to a state-of-the-art WB sensor [4], it occupies 6 × less area and achieves comparable relative accuracy over a 76% wider operating range. Session 10.3 Green Open Access added to TU Delft Institutional Repository ‘You share, we take care!’ – Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.Electronic InstrumentationMicroelectronic
A ±25A Versatile Shunt-Based Current Sensor with 10kHz Bandwidth and ±0.25% Gain Error from -40°C to 85°C Using 2-Current Calibration
Accurate current sensing is critical in many industrial applications, such as battery management and motor control. Precise shunt-based current sensors have been reported with gain errors of less than 1% over the industrial temperature range (-40°C to 85°C) [1]–[4]. However, since they are intended for coulomb counting, their bandwidth is limited to a few tens of Hz, making them unsuitable for battery impedance or motor-current sensing. This paper presents a current sensor with a wide (10kHz) bandwidth and a tunable temperature compensation scheme (TCS), which allows it to be flexibly used with different types of shunts while maintaining high accuracy. A low-cost room-temperature calibration scheme is proposed to optimize gain flatness over temperature by exploiting the shunt's self-heating at large currents. Over the industrial temperature range and a ±25A current range, it achieves state-of-the-art gain error (±0.25%) with both low-cost PCB and stable metal-alloy shunts.Green Open Access added to TU Delft Institutional Repository 'You share, we take care!' - Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.Electronic InstrumentationMicroelectronic
Regional cerebral saturation monitoring during withdrawal of life support until death
Aims: The aim of this pilot study was to explore the regional cerebral oxygen saturation (rSO(2)) during the process of dying in Intensive Care Unit (ICU) patients in whom it was decided to withdraw life support. Methods: Regional cerebral saturation was measured from the moment active treatment was stopped until the moment of death, defined as the onset of asystole. Simultaneously, heart rate and arterial blood pressure were recorded using a radial arterial catheter. Baseline rSO(2) values were calculated as mean values over one hour in stable haemodynamic conditions immediately after the decision to withdraw life support. Results: Cerebral saturation was measured in six dying ICU patients. The mean age of patients was 64 year. The median baseline rSO(2) value was 64% (58%-68%). At time of death, median rSO(2) was 33% (7%-40%). The median decrease in rSO(2) from baseline until death was 31% (25%-45%). The median decrease in rSO(2) observed during the last hour before time of death was 20% (12%-31%). Conclusion: A continuous and patient specific decrease in rSO(2) was observed in all patients with a simultaneous decrease in MAP. However, the absolute rSO(2) value at moment death was clinically determined, had a broad range, indicating that there is no clear cut-off rSO(2) value for death probably due to the heterogeneity of the studied population. Taken together, these observations highlight the importance of following trends and comparing rSO(2) values in the cardiac arrest setting. (C) 2017 Elsevier B.V. All rights reserved.This study is part of the Limburg Clinical Research Program (LCRP) UHasselt-ZOL-Jessa, supported by the foundation Limburg Sterk Merk, Hasselt University, Ziekenhuis Oost-Limburg and Jessa Hospital
The prognostic value of bispectral index and suppression ratio monitoring after out-of-hospital cardiac arrest. A prospective observational study.
Background: We investigated the ability of bispectral index (BIS) monitoring to predict poor neurological outcome in out-of-hospital cardiac arrest (OHCA) patients fully treated according to guidelines.
Results: In this prospective, observational study, 77 successfully resuscitated OHCA patients were enrolled in whom BIS, suppression ratio (SR) and electromyographic (EMG) values were continuously monitored during the frst 36 h after the initiation of targeted temperature management at 33 °C. The Cerebral Performance Category (CPC) scale was used to defne patients’ outcome at 180 days after OHCA (CPC 1–2: good–CPC 3–5: poor neurological outcome). Using mean BIS and SR values calculated per hour, receiver operator characteristics curves were constructed to determine the optimal time point and threshold to predict poor neurological outcome. At 180 days post-cardiac arrest, 39 patients (51%) had a poor neurological outcome. A mean BIS value≤25 at hour 12 predicted poor neurological outcome with a sensitivity of 49% (95% CI 30–65%), a specifcity of 97% (95% CI 85–100%) and false positive rate (FPR) of
6% (95% CI 0–29%) [AUC: 0.722 (0.570–0.875); p=0.006]. A mean SR value≥3 at hour 23 predicted poor neurological with a sensitivity of 74% (95% CI 56–87%), a specifcity of 92% (95% CI 78–98%) and FPR of 11% (95% CI 3–29%) [AUC: 0.836 (0.717–0.955); p<0.001]. No relationship was found between mean EMG and BIS<25 (R2=0.004; p=0.209).
Conclusion: This study found that mean BIS≤25 at hour 12 and mean SR≥3 at hour 23 might be used to predict poor neurological outcome in an OHCA population with a presumed cardiac cause. Since no correlation was observed between EMG and BIS<25, our calculated BIS threshold might assist with poor outcome prognostication following OHCA.This work was supported by the Limburg Clinical Research Program (LCRP) UHasselt-ZOL-Jessa, supported by the foundation Limburg Sterk Merk, Hasselt University, Ziekenhuis Oost-Limburg and Jessa Hospital
- …
