Bed rest after cardiovascular implantable electronic device placement: systematic review and meta-analysis
BACKGROUND:
Bed rest is prescribed for all patients after cardiovascular implantable electronic device (CIED) placement but to a varied extent. Different clinical protocols exist.
AIM:
To assess the effects of different lengths of bed rest on complications and patient comfort after CIED implantation.
METHODS:
We searched MEDLINE, EMBASE, Cochrane Database of Systematic Reviews, CINAHL, SCOPUS. We included randomized and quasi-randomized controlled trials. Two of the authors independently selected trials, assessed the risk of bias, and extracted data.
RESULTS:
We included 2 RCTs. There was no evidence that shorter bed rest was more harmful than longer bed rest in terms of lead displacement (RR 0.681, 95% CI [0.063, 7.332]) and hematoma (RR 1.642, 95% CI [0.282, 9.560]). None of the studies reported the assessment of bleeding, back pain, or urinary discomfort.
CONCLUSIONS:
Shorter periods of bed rest appear to be as safe as longer ones. However, to confirm these results, further larger trials are needed
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Bed rest for preventing complications after transfemoral cardiac catheterisation: a protocol of systematic review and network meta-analysis.
BACKGROUND: Transfemoral cardiac catheterisation is an invasive medical procedure used for therapeutic or diagnostic purposes. Postoperative bed rest can prevent a number of complications such as bleeding and haematoma formation and can result in side effects such as back pain and urinary discomfort. Currently, there is no consensus regarding the optimal length of bed rest. Our objective is to assess the effects of post-catheterisation length of bed rest on bleeding and haematoma, other vascular complications, patient symptoms and patient discomfort, among patients who underwent transfemoral cardiac catheterisation. METHODS: We wrote this protocol in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses Protocols statement. We defined the search query by using the PICO framework (Population: Patients undergoing cardiac catheterisation; INTERVENTION: early mobilisation; Comparison: late mobilisation; OUTCOMES: early and late complications). We will search six biomedical databases and five online registries to obtain both published and unpublished studies. We will include randomised controlled trials and quasi-randomised controlled trials, and their quality will be independently appraised with the Cochrane Effective Practice and Organisation of Care criteria for quality assessment. We will carry out a pairwise meta-analysis and network meta-analysis to estimate the overall intervention effects from both direct and indirect comparisons. DISCUSSION: This review may have considerable implications for practice and help to achieve an effective and efficient management of patients who underwent cardiac catheterisation. This review will be grounded in an expanded search of 11 resources and will employ innovative statistical methods such as network meta-analysis. SYSTEMATIC REVIEW REGISTRATION: PROSPERO registration number: CRD42014014222
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
Short Versus Long Timing of Flushing of Totally Implantable Venous Access Devices When Not Used Routinely: A Systematic Review and Meta-analysis
Background: Flushing and locking of totally implantable venous access devices (TIVADs) is recommended to maintain their patency when not in use. Although manufacturers' recommendations indicate monthly access for TIVAD maintenance, there is a tendency in real life to prolong this interval.
Objectives: To assess the effectiveness of prolonged versus short flushing and locking intervals to prevent TIVAD occlusions in adults with cancer.
Methods: A systematic search was carried out in MEDLINE, EMBASE, CINAHL, and Web of Science. Two reviewers independently selected studies, assessed quality, and extracted data. Study findings were summarized, and a meta-analysis conducted.
Results: Six articles were included in the review, with a total of 1255 participants. Differences in types of cancers, flushing and locking techniques, and volume and concentration of heparin were described. Pooled results from 4 studies showed fewer catheter occlusions in favor of prolonged flushing and locking intervals (relative risk, 0.81), even if not statistically significant (95% confidence interval, 0.41-1.61) with no heterogeneity among studies (I2 = 0.00%, P = .69). The quality of evidence was very low.
Conclusions: Very low-quality evidence suggests that prolonged schedule flushing and locking intervals has no effect on catheter patency. However, because of low number and poor quality of evidence derived from the studies analyzed, findings of this meta-analysis should be interpreted with caution.
Implications for practice: No statistically significant difference in occlusion rate between short and long timing of flushing was found. However, further studies are necessary to strengthen the safe implementation of longer intervals in clinical practice
koamabayili/VECTRON-author-checklist: VECTRON author checklist
We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
- …