1,721,003 research outputs found

    Full-Wave Simulation of a Helmholtz Radiofrequency Coil for Magnetic Resonance Applications

    Full text link
    Magnetic resonance imaging (MRI) is a non-invasive diagnostic technique able to provide information about the anatomical, structural, and functional properties of different organs. A magnetic resonance (MR) scanner employs radiofrequency (RF) coils to generate a magnetic field to excite the nuclei in the sample (transmit coil) and pick up the signals emitted by the nuclei (receive coil). To avoid trial-and-error approaches and optimize the RF coil performance for a given application, accurate design and simulation processes must be performed. We describe the full-wave simulation of a Helmholtz coil for high-field MRI performed with the finite-difference time-domain (FDTD) method, investigating magnetic field pattern differences between loaded and unloaded conditions. Moreover, the self-inductance of the single loops constituting the Helmholtz coil was estimated, as well as the frequency splitting between loops due to inductive coupling and the sample-induced resistance. The result accuracy was verified with data acquired with a Helmholtz prototype for small phantom experiments with a 3T MR clinical scanner. Finally, the magnetic field variations and coil detuning after the insertion of the RF shield were evaluated

    A Novel Magnetic Resonance Phased-Array Coil Designed with FDTD Algorithm

    No full text
    Radio-frequency receiver phased-array coils in magnetic resonance imaging systems are used to pick up the signals emitted by the nuclei with high signal-to-noise ratio and a large region of sensitivity. Since the quality of obtained images strongly depends upon the correct choice of the coil geometry and position, array coils have to be designed by minimizing the mutual interaction among nearby coil elements and this is generally achieved by overlapping such adjacent elements. In this paper, we describe the use of a numerical solver based on finite-difference time-domain method to determine the optimal overlap distance, which guarantees the maximum decoupling level between the coil loops, for array coils constituted by various geometry elements. A novel array coil was designed, constituted by a couple of elliptical geometry elements in "folding" version around the animals' spine curvature, for small animals' imaging applications

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Sodium radiofrequency coils for magnetic resonance: from design to applications

    Full text link
    Sodium (23Na) is the most abundant cation present in the human body and is involved in a large number of vital body functions. In the last few years, the interest in Sodium Magnetic Resonance Imaging (23Na MRI) has considerably increased for its relevance in physiological and physiopathological aspects. Indeed, sodium MRI offers the possibility to extend the anatomical imaging information by providing additional and complementary information on physiology and cellular metabolism with the heteronuclear Magnetic Resonance Spectroscopy (MRS). Constraints are the rapidly decaying of sodium signal, the sensitivity lack due to the low sodium concentration versus1H-MRI induce scan times not clinically acceptable and it also constitutes a challenge for sodium MRI. With the available magnetic fields for clinical MRI scanners (1.5 T, 3 T, 7 T), and the hardware capabilities such as strong gradient strengths with high slew rates and new dedicated radiofrequency (RF) sodium coils, it is possible to reach reasonable measurement times (~10–15 min) with a resolution of a few millimeters, where it has already been applied in vivo in many human organs such as the brain, cartilage, kidneys, heart, as well as in muscle and the breast. In this work, we review the different geometries and setup of sodium coils described in the available literature for different in vivo applications in human organs with clinical MR scanners, by providing details of the design, modeling and construction of the coils

    Relationships Between Morphologic and Functional Patterns in the Polymicrogyric Cortex

    No full text
    Polymicrogyria is a malformation of cortical folding and layering underlying different cognitive and neurological manifestations. The polymicrogyric cortex has heterogeneous morphofunctional patterns, qualitatively described at magnetic resonance imaging (MRI) by variable severity gradients and functional activations. We investigated the link between abnormal cortical folding and cortical function in order to improve surgical planning for patients with polymicrogyria and intractable epilepsy. We performed structural and functional MRI on 14 patients with perisylvian polymicrogyria and adopted surface-based methods to detect alterations of cortical thickness (CT) and local gyrification index (LGI) compared with normal cortex (30 age-matched subjects). We quantitatively assessed the grade of anatomic disruption of the polymicrogyric cortex and defined its relationship with decreased cortical function. We observed a good matching between visual analysis and morphometric measurements. CT maps revealed sparse clusters of thickening, while LGI maps disclosed circumscribed regions of maximal alteration with a uniformly decreasing centrifugal gradient. In polymicrogyric areas in which gyral and sulcal patterns were preserved, functional activation maintained the expected location, but was reduced in extent. Morphofunctional correlations, evaluated along cortico-cortical paths between maximum morphologic alterations and significant activations, identified an interindividual threshold for LGI (z-value = −1.09) beyond which functional activations were no longer identifiable

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Full text link
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Dispelling the Myths Behind First-author Citation Counts

    Full text link
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods
    corecore