1,720,959 research outputs found
Sensory unpleasantness of very-high frequency sound and audible ultrasound
Audible very-high frequency sound (VHFS) and ultrasound (US) have been rated more unpleasant than lower frequency sounds when presented to listeners at similar sensation levels (SLs). In this study, 17 participants rated the sensory unpleasantness of 14-, 16-, and 18-kHz tones and a 1-kHz reference tone. Tones were presented at equal subjective loudness levels for each individual, corresponding to levels of 10, 20, and 30 dB SL measured at 1 kHz. Participants were categorized as either “symptomatic” or “asymptomatic” based on self-reported previous symptoms that they attributed to exposure to VHFS/US. In both groups, subjective loudness increased more rapidly with sound pressure level for VHFS/US than for the 1-kHz reference tone, which is consistent with a reduced dynamic range at the higher frequencies. For loudness-matched tones, participants rated VHFS/US as more unpleasant than that for the 1-kHz reference. These results suggest that increased sensory unpleasantness and reduced dynamic range at high frequencies should be considered when designing or deploying equipment which emits VHFS/US that could be audible to exposed people.</p
Improved tactile speech robustness to background noise with a dual-path recurrent neural network noise-reduction method
Many people with hearing loss struggle to understand speech in noisy environments, making noise robustness critical for hearing-assistive devices. Recently developed haptic hearing aids, which convert audio to vibration, can improve speech-in-noise performance for cochlear implant (CI) users and assist those unable to access hearing-assistive devices. They are typically body-worn rather than head-mounted, allowing additional space for batteries and microprocessors, and so can deploy more sophisticated noise-reduction techniques. The current study assessed whether a real-time-feasible dual-path recurrent neural network (DPRNN) can improve tactile speech-in-noise performance. Audio was converted to vibration on the wrist using a vocoder method, either with or without noise reduction. Performance was tested for speech in a multi-talker noise (recorded at a party) with a 2.5-dB signal-to-noise ratio. An objective assessment showed the DPRNN improved the scale-invariant signal-to-distortion ratio by 8.6 dB and substantially outperformed traditional noise-reduction (log-MMSE). A behavioural assessment in 16 participants showed the DPRNN improved tactile-only sentence identification in noise by 8.2%. This suggests that advanced techniques like the DPRNN could substantially improve outcomes with haptic hearing aids. Low-cost haptic devices could soon be an important supplement to hearing-assistive devices such as CIs or offer an alternative for people who cannot access CI technology
Improved tactile speech perception and noise robustness using audio-to-tactile sensory substitution with amplitude envelope expansion
Recent advances in haptic technology could allow haptic hearing aids, which convert audio to tactile stimulation, to become viable for supporting people with hearing loss. A tactile vocoder strategy for audio-to-tactile conversion, which exploits these advances, has recently shown significant promise. In this strategy, the amplitude envelope is extracted from several audio frequency bands and used to modulate the amplitude of a set of vibro-tactile tones. The vocoder strategy allows good consonant discrimination, but vowel discrimination is poor and the strategy is susceptible to background noise. In the current study, we assessed whether multi-band amplitude envelope expansion can effectively enhance critical vowel features, such as formants, and improve speech extraction from noise. In 32 participants with normal touch perception, tactile-only phoneme discrimination with and without envelope expansion was assessed both in quiet and in background noise. Envelope expansion improved performance in quiet by 10.3% for vowels and by 5.9% for consonants. In noise, envelope expansion improved overall phoneme discrimination by 9.6%, with no difference in benefit between consonants and vowels. The tactile vocoder with envelope expansion can be deployed in real-time on a compact device and could substantially improve clinical outcomes for a new generation of haptic hearing aids.</p
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
koamabayili/VECTRON-author-checklist: VECTRON author checklist
We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
- …
