9 research outputs found

    Foutrobuuste Compressie van Digitale Videodata

    No full text
    Electrical Engineering, Mathematics and Computer Scienc

    Reference Network and Localization Architecture for Smart Manufacturing Based on 5G

    No full text
    5G promises to shift Industry 4.0 to the next level by allowing flexible production. However, many communication standards are used throughout a production site, which will stay so in the foreseeable future. Furthermore, localization of assets will be equally valuable in order to get to a higher level of automation. This paper proposes a reference architecture for a convergent localization and communication network for smart manufacturing that combines 5G with other existing technologies and focuses on high-mix, low-volume applications, particularly at small and medium-sized enterprises. The architecture is derived from a set of functional requirements, and we describe different views on this architecture to show how the requirements can be fulfilled. It connects private and public mobile networks with local networking technologies to achieve a flexible setup addressing many industrial use cases.Green Open Access added to TU Delft Institutional Repository 'You share, we take care!' - Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.Mechatronic Desig

    Experimental and Theoretical Correlation of Modulated Architectures of β-Ag2MoO4 Microcrystals: Effect of Different Synthesis Routes on the Morphology, Optical, Colorimetric, and Photocatalytic Properties

    No full text
    In this paper, the effect of different synthesis methods, such as controlled precipitation (CP), sonochemical, hot solution ion injection with fast cooling, and conventional hydrothermal in obtaining beta-disilver molybdate (β-Ag2MoO4) are explained in details. X-ray diffraction patterns, Rietveld refinement data, cluster modeling, micro-Raman, and Fourier transform infrared spectroscopies confirmed that all β-Ag2MoO4 crystals have a spinel-like cubic structure, space group (Fd 3¯¯¯ m), and symmetry point group (O7h ). Field emission scanning electron microscopy (FE-SEM) images showed that through different synthetic routes, it is possible to obtain monophasic crystals, such as regular/irregular polyhedrons (cubes, cuboctahedron, trapezohedron, rhombic dodecahedron), potatoes, and non-uniform. The crystal shape observed experimentally was modeled based on Rietveld refinement data and FE-SEM images obtained by KrystalShaper program. First-principles quantum mechanical calculations based on density functional theory were employed to modulate the crystals’ surfaces and to obtain their surface energy (Esurf) values. From these Esurf values in association with the Wulff construction, the evolution of the crystals shape was achieved correlating with the experimental results when different synthesis methods are used. Ultraviolet–Visible (UV–Vis) spectroscopy measurements in absorbance mode showed three main absorptions (280, 310, and 340 nm), while the UV–Vis analyses in diffuse reflectance mode showed a tail of energy absorption in the UV spectrum range (3.25 eV and 3.3 eV). The quantitative data from the colorimetric analysis indicated that the β-Ag2MoO4 crystals are desirable for developing inorganic pigments with a beige to brown shade. Photocatalytic assays were performed using four lamps: UV-C, UV-B, UV-A, and visible light. The β-Ag2MoO4 crystals prepared by the CP method showed a higher degradation rate at 85.12% for the Rhodamine B dye solution under 240 min exposure to UV-C light

    Dynamic rubidium-82 PET/CT as a novel tool for quantifying hemodynamic differences in renal blood flow using a one-tissue compartment model

    No full text
    Purpose: Assessing renal perfusion in-vivo is challenging and quantitative information regarding renal hemodynamics is hardly incorporated in medical decision-making while abnormal renal hemodynamics might play a crucial role in the onset and progression of renal disease. Combining physiological stimuli with rubidium-82 positron emission tomography/computed tomography (82Rb PET/CT) offers opportunities to test the kidney perfusion under various conditions. The aim of this study is: (1) to investigate the application of a one-tissue compartment model for measuring renal hemodynamics with dynamic 82Rb PET/CT imaging, and (2) to evaluate whether dynamic PET/CT is sensitive to detect differences in renal hemodynamics in stress conditions compared to resting state. Methods: A one-tissue compartment model for the kidney was applied to cardiac 82Rb PET/CT scans that were obtained for ischemia detection as part of clinical care. Retrospective data, collected from 17 patients undergoing dynamic myocardial 82Rb PET/CT imaging in rest, were used to evaluate various CT-based volumes of interest (VOIs) of the kidney. Subsequently, retrospective data, collected from 10 patients (five impaired kidney functions and five controls) undergoing dynamic myocardial 82Rb PET/CT imaging, were used to evaluate image-derived input functions (IDIFs), PET-based VOIs of the kidney, extraction fractions, and whether dynamic 82Rb PET/CT can measure renal hemodynamics differences using the renal blood flow (RBF) values in rest and after exposure to adenosine pharmacological stress. Results: The delivery rate (K1) values showed no significant (p = 0.14) difference between the mean standard deviation (SD) K1 values using one CT-based VOI and the use of two, three, and four CT-based VOIs, respectively 2.01(0.32), 1.90(0.40), 1.93(0.39), and 1.94(0.40) mL/min/mL. The ratio between RBF in rest and RBF in pharmacological stress for the controls were overall significantly lower compared to the impaired kidney function group for both PET-based delineation methods (region growing and iso-contouring), with the smallest median interquartile range (IQR) of 0.40(0.28–0.66) and 0.96(0.62–1.15), respectively (p < 0.05). The K1 of the impaired kidney function group were close to 1.0 mL/min/mL. Conclusions: This study demonstrated that obtaining renal K1 and RBF values using 82Rb PET/CT was feasible using a one-tissue compartment model. Applying iso-contouring as the PET-based VOI of the kidney and using AA as an IDIF is suggested for consideration in further studies. Dynamic 82Rb PET/CT imaging showed significant differences in renal hemodynamics in rest compared to when exposed to adenosine. This indicates that dynamic 82Rb PET/CT has potential to detect differences in renal hemodynamics in stress conditions compared to the resting state, and might be useful as a novel diagnostic tool for assessing renal perfusion.RST/Radiation, Science and Technolog

    Deep learning image enhancement algorithms in PET/CT imaging: a phantom and sarcoma patient radiomic evaluation

    No full text
    PET/CT imaging data contains a wealth of quantitative information that can provide valuable contributions to characterising tumours. A growing body of work focuses on the use of deep-learning (DL) techniques for denoising PET data. These models are clinically evaluated prior to use, however, quantitative image assessment provides potential for further evaluation. This work uses radiomic features to compare two manufacturer deep-learning (DL) image enhancement algorithms, one of which has been commercialised, against 'gold-standard' image reconstruction techniques in phantom data and a sarcoma patient data set (N=20). All studies in the retrospective sarcoma clinical [ F]FDG dataset were acquired on either a GE Discovery 690 or 710 PET/CT scanner with volumes segmented by an experienced nuclear medicine radiologist. The modular heterogeneous imaging phantom used in this work was filled with [ F]FDG, and five repeat acquisitions of the phantom were acquired on a GE Discovery 710 PET/CT scanner. The DL-enhanced images were compared to 'gold-standard' images the algorithms were trained to emulate and input images. The difference between image sets was tested for significance in 93 international biomarker standardisation initiative (IBSI) standardised radiomic features. Comparing DL-enhanced images to the 'gold-standard', 4.0% and 9.7% radiomic features measured significantly different (p < 0.0005) in the phantom and patient data respectively (averaged over the two DL algorithms). Larger differences were observed comparing DL-enhanced images to algorithm input images with 29.8% and 43.0% of radiomic features measuring significantly different in the phantom and patient data respectively (averaged over the two DL algorithms). DL-enhanced images were found to be similar to images generated using the 'gold-standard' target image reconstruction method with more than 80% of radiomic features not significantly different in all comparisons across unseen phantom and sarcoma patient data. This result offers insight into the performance of the DL algorithms, and demonstrate potential applications for DL algorithms in harmonisation for radiomics and for radiomic features in quantitative evaluation of DL algorithms. [Abstract copyright: © 2025. The Author(s).

    Investigating the potential added value of [ 18 F]FDG-PET/CT in long COVID patients with persistent symptoms: a proof of concept study

    No full text
    OBJECTIVE: Since the end of 2019, the coronavirus disease 2019 (COVID-19) virus has infected millions of people, of whom a significant group suffers from sequelae from COVID-19, termed long COVID. As more and more patients emerge with long COVID who have symptoms of fatigue, myalgia and joint pain, we must examine potential biomarkers to find quantifiable parameters to define the underlying mechanisms and enable response monitoring. The aim of this study is to investigate the potential added value of [ 18 F]FDG-PET/computed tomography (CT) for this group of long COVID patients. METHODS: For this proof of concept study, we evaluated [ 18 F]FDG-PET/CT scans of long COVID patients and controls. Two analyses were performed: semi-quantitative analysis using target-to-background ratios (TBRs) in 24 targets and total vascular score (TVS) assessed by two independent nuclear medicine physicians. Mann-Whitney U -test was performed to find significant differences between the two groups. RESULTS: Thirteen patients were included in the long COVID group and 25 patients were included in the control group. No significant differences ( P  < 0.05) were found between the long COVID group and the control group in the TBR or TVS assessment. CONCLUSION: As we found no quantitative difference in the TBR or TVS between long COVID patients and controls, we are unable to prove that [ 18 F]FDG is of added value for long COVID patients with symptoms of myalgia or joint pain. Prospective cohort studies are necessary to understand the underlying mechanisms of long COVID

    Design and evaluation of a modular multimodality imaging phantom to simulate heterogeneous uptake and enhancement patterns for radiomic quantification in hybrid imaging: A feasibility study

    No full text
    Background: Accuracy and precision assessment in radiomic features is important for the determination of their potential to characterize cancer lesions. In this regard, simulation of different imaging conditions using specialized phantoms is increasingly being investigated. In this study, the design and evaluation of a modular multimodality imaging phantom to simulate heterogeneous uptake and enhancement patterns for radiomics quantification in hybrid imaging is presented. Methods: A modular multimodality imaging phantom was constructed that could simulate different patterns of heterogeneous uptake and enhancement patterns in positron emission tomography (PET), single-photon emission computed tomography (SPECT), computed tomography (CT), and magnetic resonance (MR) imaging. The phantom was designed to be used as an insert in the standard NEMA-NU2 IEC body phantom casing. The entire phantom insert is composed of three segments, each containing three separately fillable compartments. The fillable compartments between segments had different sizes in order to simulate heterogeneous patterns at different spatial scales. The compartments were separately filled with different ratios of 99mTc-pertechnetate, 18F-fluorodeoxyglucose ([18F]FDG), iodine- and gadolinium-based contrast agents for SPECT, PET, CT, and T1-weighted MR imaging respectively. Image acquisition was performed using standard oncological protocols on all modalities and repeated five times for repeatability assessment. A total of 93 radiomic features were calculated. Variability was assessed by determining the coefficient of quartile variation (CQV) of the features. Comparison of feature repeatability at different modalities and spatial scales was performed using Kruskal-Wallis-, Mann-Whitney U-, one-way ANOVA- and independent t-tests. Results: Heterogeneous uptake and enhancement could be simulated on all four imaging modalities. Radiomic features in SPECT were significantly less stable than in all other modalities. Features in PET were significantly less stable than in MR and CT. A total of 20 features, particularly in the gray-level co-occurrence matrix (GLCM) and gray-level run-length matrix (GLRLM) class, were found to be relatively stable in all four modalities for all three spatial scales of heterogeneous patterns (with CQV &lt; 10%). Conclusion: The phantom was suitable for simulating heterogeneous uptake and enhancement patterns in [18F]FDG-PET, 99mTc-SPECT, CT, and T1-weighted MR images. The results of this work indicate that the phantom might be useful for the further development and optimization of imaging protocols for radiomic quantification in hybrid imaging modalities.EMSD AS-south Project engineersRST/Medical Physics & Technolog

    The influence of the exclusion of central necrosis on [18F]FDG PET radiomic analysis

    No full text
    Background: Central necrosis can be detected on [18F]FDG PET/CT as a region with little to no tracer uptake. Currently, there is no consensus regarding the inclusion of regions of central necrosis during volume of interest (VOI) delineation for radiomic analysis. The aim of this study was to assess how central necrosis affects radiomic analysis in PET. Methods: Forty-three patients, either with non-small cell lung carcinomas (NSCLC, n = 12) or with pheochromocytomas or paragangliomas (PPGL, n = 31), were included retrospectively. VOIs were delineated with and without central necrosis. From all VOIs, 105 radiomic features were extracted. Differences in radiomic features between delineation methods were assessed using a paired t-test with Benjamini-Hochberg multiple testing correction. In the PPGL cohort, performances of the radiomic models to predict the noradrenergic biochemical profile were assessed by comparing the areas under the receiver operating characteristic curve (AUC) for both delineation methods. Results: At least 65% of the features showed significant differences between VOIvital-tumour and VOIgross-tumour (65%, 79% and 82% for the NSCLC, PPGL and combined cohort, respectively). The AUCs of the radiomic models were not significantly different between delineation methods. Conclusion: In both tumour types, almost two-third of the features were affected, demonstrating that the impact of whether or not to include central necrosis in the VOI on the radiomic feature values is significant. Nevertheless, predictive performances of both delineation methods were comparable. We recommend that radiomic studies should report whether or not central necrosis was included during delineation
    corecore