1,720,967 research outputs found
Innovations in Corneal Crosslinking.
PURPOSE
Corneal Crosslinking (CXL) strengthens the keratoconus cornea and prevents further disease progression. Modified crosslinking protocols and different riboflavin solutions have been proposed to optimize the procedure and improve treatment success.
METHODS
PubMed research of relevant publications and report of own experiences with different CXL protocols.
RESULTS
Accelerated CXL shows comparable efficiency with shorter surgery time and similar complication rates. Customized CXL provides improved results with faster epithelial healing. CXL in a hyperoxic environment seems to be a safe and effective transepithelial alternative with presumably less complications and fewer side effects. Thin corneas (<400 µm) can be treated safely by corneal swelling using hypoosmolar riboflavin solutions and reducing the applied UV-energy. The combination of CXL with photorefractive keratectomy (PRK) can be considered in patients with contact lens intolerance improving visual acuity, however, with increased risk of visual loss compared to CXL alone. Two-Photon (2Ph) CXL is a promising new technology enabling three-dimensional CXL.
DISCUSSION
Recently developed CXL protocols offer advantages over the standard "Dresden-protocol" and should be considered in patients with progressive keratectasia
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Customized Corneal Cross-linking: One-Year Results.
PURPOSE
To compare the efficacy of customized corneal cross-linking (CXL) with standard CXL.
DESIGN
Prospective, nonrandomized comparative clinical study.
METHODS
In a prospective study at the Institut für Refraktive und Ophthalmo-Chirurgie (IROC), Zurich, Switzerland, 40 eyes of 40 patients with documented progressive primary keratoconus were treated with customized CXL (n = 20) or standard CXL (n = 20) and followed for 1 year. Customized irradiation patterns had an energy fluence of 9 mW/cm(2) and total energy levels ranging from 5.4 J/cm(2) up to 10 J/cm(2) and were centered on the maximum of the posterior float. The control group received homogenous irradiation with a fluence of 9 mW/cm(2) and a total energy of 5.4 J/cm(2). Scheimpflug tomographies, endothelium cell count, best spectacle-corrected visual acuity (BSCVA), and anterior segment optical coherence tomography (OCT) were compared preoperatively and 1 year postoperatively.
RESULTS
Pachymetry and ΔKmax showed significant changes 1 year postoperatively within each group. Epithelial healing time, ΔKmax, and regularization index (RI) were significantly better in the customized CXL group. Two out of 19 eyes (11%) in the standard group but 7 out of 19 eyes (37%) in the customized CXL group showed a flattening of 2 or more diopters (P = .03). The RI was 5.2 ± 2.7 D in the customized group vs 4.1 ± 3.1 D in the control group (P = .03). Statistically significant correlations between RI and preoperative Kmax, preoperative pachymetry, and preoperative posterior float were found only in the customized group.
CONCLUSIONS
Customized CXL seems to be as safe as standard CXL with stronger flattening in Kmax and RI, and a faster epithelial healing period
Comparison of Corneal Riboflavin Gradients Using Dextran and HPMC Solutions.
PURPOSE
To determine the riboflavin concentration gradient in the anterior corneal stroma when using hydroxypropyl methylcellulose (HPMC) or dextran as the carrier agent.
METHODS
Four different groups of porcine corneas (5 each) were compared regarding the riboflavin concentration in the anterior stroma. Prior to all experiments, stable hydration conditions were established for the corresponding solution. The dextran groups were treated with 0.1% riboflavin in 20% dextran for 10 and 30 minutes and the HPMC groups with 0.1% riboflavin in 1.1% HPMC for 10 and 30 minutes. After imbibition, nonlinear microscopy and consecutive image analysis were used to determine two-photon fluorescence intensities. To determine the riboflavin concentration, corneas were saturated and measured a second time by two-photon microscopy. With this measurement, a proper correction for absorption and scattering could be performed. Ultraviolet-A (UVA) transmission was measured after the application time for each group.
RESULTS
Riboflavin concentration decreased with increasing depth and increased with longer application times in all groups. Comparing the dextran for 30 minutes and HPMC for 10 minutes groups, a significantly higher stromal riboflavin concentration was found within the most anterior 70 µm in the dextran group for 30 minutes, whereas deeper than 260 µm HPMC-assisted imbibition for 10 minutes yielded higher concentrations. In dextran-treated corneas, values obtained from pachymetry were substantially reduced, whereas HPMC-assisted imbibition led to a decent swelling. UVA transmission values were higher in dextran-assisted imbibition than in HPMC-assisted imbibition.
CONCLUSIONS
Stromal riboflavin gradients are similar when applied in dextran for 30 minutes and HPMC for 10 minutes. When using HPMC solutions, a shallower cross-linked volume is expected due to a higher corneal hydration. [J Refract Surg. 2016;32(12):798-802.]
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
koamabayili/VECTRON-author-checklist: VECTRON author checklist
We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
- …
