1,721,682 research outputs found

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Get PDF
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Get PDF
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Get PDF
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Deflated preconditioned Conjugate Gradient methods for noise filtering of low-field MR images

    No full text
    We study efficient implicit methods to denoise low-field MR images using a nonlinear diffusion operator as a regularizer. This problem can be formulated as solving a nonlinear reaction–diffusion equation. After discretization, a lagged-diffusion approach is used which requires a linear system solve in every nonlinear iteration. The choice of diffusion model determines the denoising properties, but it also influences the conditioning of the linear systems. As a solution method, we use Conjugate Gradient (CG) in combination with a suitable preconditioner and deflation technique. We consider four different preconditioners in combination with subdomain deflation. We evaluate the methods for four commonly used denoising operators: standard Laplace operator, two Perona–Malik type operators, and the Total Variation (TV) operator. We show that a Discrete Cosine Transform (DCT) preconditioner works best for problems with a slowly varying diffusion coefficient, while Jacobi preconditioning with subdomain deflation works best for a strongly varying diffusion, as happens for the TV operator. This research is part of a larger effort that aims to provide low-cost MR imaging capabilities for low-resource settings. We have evaluated the algorithms on low-field MRI images using inexpensive commodity hardware. With a suitable preconditioner for the chosen diffusion model, we are able to limit the time to denoise three-dimensional images of more than 2 million pixels to less than 15 s, which is fast enough to be used in practice.Green Open Access added to TU Delft Institutional Repository ‘You share, we take care!’ – Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.Numerical Analysi

    Occult cerebral vascular malformations: high-field MR imaging.

    No full text
    Occult cerebral vascular malformations (OCVMs) have characteristic appearances on high-field magnetic resonance (MR) images. These consist of circumscribed regions of low intensity, most prominent on T2-weighted images and representing hemosiderin deposits. Interspersed within most of these lesions are multiple areas of various signal intensity patterns, which correspond to hematomas in different stages of evolution and to fibrous regions containing calcium as well as hemosiderin. Forty-six lesions were found in 19 patients (34 supratentorial and 12 infratentorial). The supratentorial lesions tended to be subcortical or periventricular. Computed tomography depicted 24 of the 46 lesions demonstrated by high-field MR. Comparison of images obtained with both low-field MR (0.12 T and 0.35 T) and high-field MR (1.5 T) revealed that high-field MR imaging was superior in depicting OCVMs. High-field MR appears to be both sensitive and specific for OCVMs and may obviate the need for possible biopsy of these lesions

    Dispelling the Myths Behind First-author Citation Counts

    Get PDF
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Author Index

    No full text
    Nao informado

    koamabayili/VECTRON-author-checklist: VECTRON author checklist

    No full text
    We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used

    Deep learning-based single image super-resolution for low-field MR brain images

    Get PDF
    Low-field MRI scanners are significantly less expensive than their high-field counterparts, which gives them the potential to make MRI technology more accessible all around the world. In general, images acquired using low-field MRI scanners tend to be of a relatively low resolution, as signal-to-noise ratios are lower. The aim of this work is to improve the resolution of these images. To this end, we present a deep learning-based approach to transform low-resolution low-field MR images into high-resolution ones. A convolutional neural network was trained to carry out single image super-resolution reconstruction using pairs of noisy low-resolution images and their noise-free high-resolution counterparts, which were obtained from the publicly available NYU fastMRI database. This network was subsequently applied to noisy images acquired using a low-field MRI scanner. The trained convolutional network yielded sharp super-resolution images in which most of the high-frequency components were recovered. In conclusion, we showed that a deep learning-based approach has great potential when it comes to increasing the resolution of low-field MR images.Numerical AnalysisSignal Processing System
    corecore