1,721,219 research outputs found
Using patient specific finite element models to understand the biomechanics of paediatric spinal deformity surgery
Adolescent idiopathic scoliosis (AIS) is a spinal deformity, which may require surgical correction by attaching rods to the patient’s spine using screws inserted into the vertebrae. Complication rates for deformity correction surgery are unacceptably high. Determining an achievable correction without overloading the adjacent spinal tissues or implants requires an understanding of the mechanical interaction between these components. We have developed novel patient specific modelling software to create individualized finite element models (FEM) representing the thoracolumbar spine and ribcage of scoliosis patients. We are using these models to better understand the biomechanics of spinal deformity correction
Comparison of eight published lumbar spine finite element models
Due to its ability to represent intricate systems with material nonlinearities as well as irregular loading, boundary, geometrical and material domains, the finite element (FE) method has been recognized as an important computational tool in spinal biomechanics. Current FE models generally account for a single distinct spinal geometry with one set of material properties despite inherently large inter-subject variability. The uncertainty and high variability in tissue material properties, geometry, loading and boundary conditions has cast doubt on the reliability of their predictions and comparability with reported in vitro and in vivo values.\ud
\ud
A multicenter study was undertaken to compare the results of eight well-established models of the lumbar spine that have been developed, validated and applied for many years. Models were subjected to pure and combined loading modes and their predictions were compared to in vitro and in vivo measurements for intervertebral rotations, disc pressures and facet joint forces.\ud
\ud
Under pure moment loading, the predicted L1-5 rotations of almost all models fell within the reported in vitro ranges; their median values differed on average by only 2° for flexion-extension, 1° for lateral bending and 5° for axial rotation. Predicted median facet joint forces and disc pressures were also in good agreement with previously published median in vitro values. However, the ranges of predictions were larger and exceeded the in vitro ranges, especially for facet joint forces. For all combined loading modes, except for flexion, predicted median segmental intervertebral rotations and disc pressures were in good agreement with in vivo values. The simulations yielded median facet joint forces of 0 N in flexion, 38 N in extension, 14 N in lateral bending and 60 N in axial rotation that could not be validated due to the paucity of in vivo facet joint forces. In light of high inter-subject variability, one must be cautious when generalizing predictions obtained from one deterministic model. \ud
\ud
This study demonstrates however that the predictive power increases when FE models are combined together. The median of individual numerical results can hence be used as an improved tool in order to estimate the response of the lumbar spine
A preliminary in vitro biomechanical evaluation of prophylactic cement augmentation of the thoracolumbar vertebrae
In this paper, the biomechanical effectiveness of prophylactic augmentation in preventing fracture was investigated. In vitro biomechanical tests were performed to assess which factors make prophylactic augmentation effective/ineffective in reducing fracture risk. Nondestructive and destructive in vitro tests were performed on isolated osteoporotic vertebrae. Five sets of three-adjacent-vertebrae were tested. The central vertebra of each triplet was tested in the natural condition (control) non-destructively (axial-compression, torsion) and destructively (axial-compression). The two adjacent vertebrae were first tested nondestructively (axial-compression, torsion) pre-augmentation; prophylactic augmentation (uni-or bi-pedicular access) was then performed delivering 5.04mL to 8.44mL of acrylic cement by means of a customized device; quality of augmentation was CT-assessed; the augmented vertebrae were re-tested nondestructively (axial-compression, torsion), and eventually loaded to failure (axial-compression). Vertebral stiffness was correlated with the first-failure, but not with ultimate failure. The force and work to ultimate failure in prophylactic-augmented vertebrae was consistently larger than in the controls. However, in some cases the first-failure force and work in the augmented vertebrae were lower than for the controls. To investigate the reasons for such unpredictable results, the correlation with augmentation quality was analyzed. Some augmentation parameters seemed more correlated with mechanical outcome (statistically not-significant due to the limited sample size): uni-pedicular access resulted in a single cement mass, which tended to increase the force and work to first-and ultimate failure. The specimens with the highest strength and toughness also had: at least 25% cement filling, cement mass shifted anteriorly, and cement-endplate contact. These findings seem to confirm that prophylactic augmentation may aid reducing the risk of fracture. However, inadequate augmentation may have detrimental consequences. This study suggests that, to improve the strength of the augmented vertebrae, more attention should be dedicated to the quality of augmentation in terms of amount and position of the injected cement
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
Trabecular bone – screw interaction. Micro-CT models and experimental push-in results.
<p>The dataset disclosed herein was employed to build the screw-bone interaction models, specifically for tasks related to screw push-in simulation.</p>
- …
