1,720,983 research outputs found

    Violence against children and adolescents: survey of the knowledge of the undergraduate student in dentistry about the conduct to be adopted in cases of suspected violence

    No full text
    Objetivo: levantar, junto a graduandos de Odontologia, o conhecimento sobre a responsabilidade ética e conduta a ser adotada ante a suspeita de violência contra criança e adolescente. Material e Métodos: Para o desenvolvimento desta pesquisa exploratória, uma amostra de 150 graduandos dos últimos anos de Odontologia de faculdades, públicas e privadas do interior do estado de São Paulo foram convidados a responder a um questionário estruturado autoaplicável, após anuir ao Termo de Consentimento Livre e Esclarecido. Resultados: A pesquisa contou com 75 participantes regularmente matriculados no quarto ou quinto ano de Odontologia de faculdades do interior do Estado de São Paulo, que responderam 19 questões. Conclusão: conclui-se conhecimento satisfatório por parte dos graduandos quanto à conduta, contudo, estes possuem certas inseguranças relacionadas ao tema, além disso demonstram interesse em saber mais sobre o tema.Objective: The purpose of this research is to raise knowledge about ethical responsibility and conduct [to be adopted] in the face of suspected violence against children and adolescents. Material and Methods: For the development of this exploratory research, a sample of 150 undergraduate students of the last years of Dentistry from public and private schools in the interior of the state of São Paulo] were invited to answer a self-administered structured questionnaire, after agreeing to the Free and Informed Consent Form. Results: The research had 75 participants regularly enrolled in the fourth or fifth year of Dentistry at schools in the interior of the State of São Paulo, who answered 19 questions. Conclusion: It is concluded that the undergraduates have satisfactory knowledge about the conduct, however, they have certain insecurities related to the theme, in addition to showing interest in knowing more about the subject

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Get PDF
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Get PDF
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Get PDF
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Dispelling the Myths Behind First-author Citation Counts

    Get PDF
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Author Index

    No full text
    Nao informado

    Efeitos de lasers de alta potência na superfície de cerâmicas vítreas de dissilicato de lítio e sua resistência de união à dentina humana

    No full text
    O objetivo desse estudo foi avaliar a eficiência da irradiação com lasers de alta potência e a influência da aplicação do silano previa ou posteriormente à irradiação com os lasers na resistência de união entre cerâmica vítrea de dissilicato de lítio, cimento resinoso e dentina humana. Foram confeccionados 50 espécimes tronco-cônicos de cerâmica (n=10), divididos aleatoriamente em 5 grupos: 1- Controle- Condicionamento com ácido hidrofluorídrico 10% por 1 min e aplicação do silano; 2- Er:YAG – irradiação com laser Er:YAG (200 mJ e 10 Hz), seguido do condicionamento com ácido hidrofluorídrico 10% por 1 min e aplicação do silano; 3- Silano + Er:YAG – Condicionamento com ácido hidrofluorídrico 10% por 1 min, aplicação do silano e irradiação com laser Er:YAG nos mesmo parâmetros do grupo anterior; 4- Nd:YAG – irradiação com laser Nd:YAG (120 mJ e 10 Hz), seguido de condicionamento com ácido hidrofluorídrico 10% por 1 min e aplicação do silano, 5- Silano + Nd:YAG - Condicionamento com ácido hidrofluorídrico 10% por 1 min, aplicação do silano e irradiação com laser Nd:YAG nos mesmo parâmetros do grupo anterior. Após os tratamentos os espécimes cerâmicos foram cimentados com cimento resinoso de presa dual à superfície de dentina de 50 molares humanos incluídos em resina acrílica ativada quimicamente. Após armazenamento por 24 h foi realizado o ensaio de tração em máquina de ensaios universais com célula de carga de 10 KgF e velocidade constante de 1mm/min. Os dados obtidos foram submetidos à ANOVA 2-fatores e teste de Dunnet (α=5%). A análise dos padrões de fratura foram analisadas em estereomicroscopio. Adicionalmente foram confeccionados 15 espécimes em cerâmica no formato cilíndrico, submetidos aos mesmo tratamentos dos grupos anteriores (n=3) e utilizados para análise do ângulo de contato e análise em microscópio eletrônico de varredura. O teste de Dunnet mostrou diferenças significativas entre o grupo controle (9,42 ± 2,27 MPa) e os grupos Er (19,25 ± 3,7 MPa) e Sil+Er (14,11 ± 4,11 MPa). A análise de variância (p<5%) para os fatores Tipo de Laser (p<0,0001) e Técnica de Silanização (p=0,0002) mostraram diferenças significativas para os dois fatores, porém não para sua interação. Assim, a irradiação com Er:YAG (16,68 MPa) mostrou-se mais eficiente que a irradiação com Nd:YAG (8,19 MPa). A técnica de silanização posterior à irradiação com laser (14,46 MPa) também se mostrou superior à silanização previa (10,41 MPa). Quanto à análise de fraturas, o grupo Controle teve prevalência de falhas adesivas em dentina e em cerâmica; os grupos Nd, Sil + Nd e Sil + Er tiveram prevalência de falhas adesivas em cerâmica, e o grupo Er apresentou predominância de falhas coesivas no cimento. A análise do ângulo de contato foi submetida aos testes ANOVA 1-fator e Tukey, apresentando diferenças significativas entre os grupos (p<0,0001). Os grupos com silanização prévia (Sil + Er = 45,60b graus; Sil + Nd = 52,10b graus) apresentaram ângulos de contato superiores aos demais, e semelhantes entre si. As imagens de Microscopia Eletrônica de Varredura mostram a presença da camada de silano sobre a superfície cerâmica no grupo Sil + Nd, e uma aparente fundição à superfície cerâmica no grupo Sil + Er. Para os Grupos Er e Nd foi possível verificar modificações no padrão normal da estrutura da cerâmica, entremeadas por áreas semelhantes ao padrão convencional do grupo Controle após condicionamento com ácido hidrofluorídrico. Conclui-se que o tratamento com laser de Érbio associado ao condicionamento com ácido hidrofluorídrico a 10% por 1 min apresenta os melhores resultados de resistência de união e ângulo de contato. O tratamento com silano previamente à irradiação melhorou a resistência de união em relação ao grupo Controle apenas quando associado ao laser de Érbio.The aim of this study was to evaluate the efficiency of irradiation with high-power lasers and the influence of silane application before or after irradiation with lasers on the bond strength between lithium disilicate glass-ceramic, resin cement and human dentin. Fifty truncated-cones ceramic specimens (n=10) were randomly divided into 5 groups: Control- etching with hydrofluoric acid 10% for 1 min and application of silane; 2- Er - Er:YAG laser irradiation (200 mJ and 10 Hz), followed by etching with hydrofluoric acid 10% for 1 min and application of silane; 3- Sil + Er - etching with hydrofluoric acid 10% for 1 min, silane application and irradiation with Er: YAG laser in the same parameters as the previous group; 4- Nd:YAG laser - irradiation with Nd: YAG laser (120 mJ and 10 Hz), followed by etching with hydrofluoric acid 10% for 1 min and application of the silane, 5- Sil + Nd- Etching with hydrofluoric acid 10% for 1 min, silane application and irradiation with Nd: YAG laser on the same parameters as the previous group. After treatment, the ceramic specimens were cemented with dual cure resin cement to the dentin of 50 human molars included in acrylic resin. After storage for 24 h it was submitted to tensile test in a universal testing machine with 10 kgf load cell and constant speed of 1 mm/min. Data were submitted to ANOVA 2-way and Dunnet test (α = 5%). The analysis of fracture patterns were analyzed in stereomicroscope. In addition were made 15 ceramic specimens in cylindrical shape, subjected to the same treatment of the above groups (n = 3) and used for analysis of the contact angle analysis and scanning electron microscope. The Dunnet test showed significant differences between Control group (9.42 ± 2.27 MPa) and Er group (19.25 ± 3.7 MPa) and Sil + Er (14.11 ± 4.11 MPa). ANOVA 2-way (p <5%) for Laser Type (p <0.0001) and Technical of Silanization (p = 0.0002) showed significant differences for both factors, but not for their interaction. Thus, the irradiation with Er:YAG laser (16,68 MPa) was more effective than irradiation with Nd:YAG laser (8,19 MPa). The technique of silanization after laser irradiation was more effective (14,46 MPa) than the previous silanization (10,41 MPa). The analysis of fractures showed a prevalence of adhesive failures on dentin and ceramic for the Control group; Nd, Sil + Nd e Sil + Er had a prevalence of adhesive failures in ceramics, and Er group presented predominance of cohesive failures in cement. The analysis of contact angle was submitted to ANOVA 1-way and Tukey test, with significant differences between the groups (p <0.0001). Groups with silanization previous to laser irradiation (Sil + Er = 45,60b degrees; Sil + Nd = 52,10b degrees) had contact angles greater than the other groups. The Scanning Electron Microscopy images showed the presence of a silane layer on the ceramic surface in Sil + Nd group, and an apparent casting of the ceramic surface in Sil + Er group. For Er and Nd Groups was possible to see changes in the normal pattern of ceramic structure, interspersed with areas similar to conventional standard control group after etching with hydrofluoric acid. It is concluded that treatment with Er:YAG laser associated with etching with hydrofluoric acid at 10% for 1 min gives the highest bond strength results and the lower contact angle, resulting in a recommended treatment. Treatment with silane previously to laser irradiation improved bond strength only when associated with the Er:YAG laser, which probably occurred by the efficiency of Er: YAG laser irradiation, and not due to the silanization technique

    Avaliação de diferentes tratamentos de superfície na resistência de união de cerâmica de di-silicato de lítio

    No full text
    The aim of this study was to evaluate the bond strength afforded by different surface treatments on IPS e.max Press ceramic united to Variolink II (both Ivoclar-Vivadent, Liechtenstein), when subjected to tensile test. 330 ceramic bases were divided into 11 groups in accordance with the surface treatment performed: C - control group J - aluminum oxide sandblast, JAraluminum oxide sandblast and silane hot air dry, GEr - surface coating with graphite and treatment with Er: YAG laser (200 mJ of energy intensity and frequency 10 Hz), GErAr - surface coating with graphite, treatment with Er: YAG laser (200 mJ of energy intensity and 10 Hz frequency) and silane hot air dry; Er - treatment with Er: YAG laser (200 mJ of energy intensity and frequency 10 Hz) ErAr - treatment with Er: YAG laser (200 mJ intensity energy and 10 Hz frequency) and silane hot air dry; GNd - coating the surface with graphite and treatment with Nd: YAG laser (120 mJ of energy and intensity of frequency 15 Hz); GNdAr - coating the surface with graphite , treatment with Nd: YAG laser (120 mJ of energy intensity and 15 Hz frequency) and silane hot air dry; Nd - treatment with Nd: YAG laser (120 mJ of energy intensity and frequency 15 Hz); NdAr - treatment with Nd: YAG laser (120 mJ of energy and intensity of frequency 15 Hz) and silane hot air dry. The resin cement that unite the specimens was cured for 40 seconds using the LED cure equipment (Radii-cal SDI). Then they were termomechanical cycled (60N, 1,000 thermical cycles and 24000 mechanical) and were submitted to the tensile test in a universal testing machine EMIC-2000. Data were tested for Dunnet ( α = 5 % ) and 3 ANOVA Way . The Er group showed higher tensile strength greater than the control group and the other groups, while the NdG group presented results of bond strength lower than the control group and the other surface treatments. The other groups did...O objetivo deste estudo foi avaliar o efeito de diferentes tratamentos de superfície na resistência de união entre a cerâmica de di-silicato de lítio IPS e.max Press (IvoclarVivadent, Liechtenstein) e o cimento resinoso Variolink II (Ivoclar Vivadent, Liechtenstein) quando submetidos a teste de tração. Para isso 330 bases tronco-cônicas de cerâmica de di-silicato de lítio foram aleatoriamente divididas em 11 grupos de acordo com o tratamento a ser realizado: C - grupo controle; J - Jateamento com óxido de alumínio (50 μm); JAr - Jateamento com óxido de alumínio (30 μm) e secagem do silano com ar quente; GEr - Revestimento da superfície com grafite e tratamento com laser Er:YAG(200 mJ de intensidade de energia e 10 Hz de frequência); GErAr – Revestimento da superfície com grafite, tratamento com laser Er:YAG (200 mJ de intensidade de energia e 10 Hz de frequência) e secagem do silano com ar quente; Er - Tratamento com laser Er:YAG (200 mJ de intensidade de energia e 10 Hz de freqüência); ErAr - Tratamento com laser Er:YAG (200 mJ de intensidade de energia e 10 Hz de frequência) e secagem do silano com ar quente; GNd – revestimento da superfície com grafite e tratamento com laser Nd:YAG (120 mJ de intensidade de energia e 15 Hz de frequência); GNdAr – Revestimento da superfície com grafite, tratamento com laser Nd:YAG (120 mJ de intensidade de energia e 15 Hz de frequência) e secagem do silano com ar quente; Nd – Tratamento com laser Nd:YAG (120 mJ de intensidade de energia e 15 Hz de frequência); NdAr – Tratamento com laser Nd:YAG (120 mJ de intensidade de energia e 15 Hz de frequência) e secagem do silano com ar quente. O cimento resinoso que uniu os espécimes foi fotoativado por 40 segundos utilizando o aparelho LED (Radii cal-SDI). Então, foi realizada a ciclagem termomecânica com carga de 60N, 1.000 ciclos termicos e 24000 mecânicos e o ensaio ..

    Avaliação de diferentes tratamentos de superfície na resistência de união de cerâmica de di-silicato de lítio

    No full text
    The aim of this study was to evaluate the bond strength afforded by different surface treatments on IPS e.max Press ceramic united to Variolink II (both Ivoclar-Vivadent, Liechtenstein), when subjected to tensile test. 330 ceramic bases were divided into 11 groups in accordance with the surface treatment performed: C - control group J - aluminum oxide sandblast, JAraluminum oxide sandblast and silane hot air dry, GEr - surface coating with graphite and treatment with Er: YAG laser (200 mJ of energy intensity and frequency 10 Hz), GErAr - surface coating with graphite, treatment with Er: YAG laser (200 mJ of energy intensity and 10 Hz frequency) and silane hot air dry; Er - treatment with Er: YAG laser (200 mJ of energy intensity and frequency 10 Hz) ErAr - treatment with Er: YAG laser (200 mJ intensity energy and 10 Hz frequency) and silane hot air dry; GNd - coating the surface with graphite and treatment with Nd: YAG laser (120 mJ of energy and intensity of frequency 15 Hz); GNdAr - coating the surface with graphite , treatment with Nd: YAG laser (120 mJ of energy intensity and 15 Hz frequency) and silane hot air dry; Nd - treatment with Nd: YAG laser (120 mJ of energy intensity and frequency 15 Hz); NdAr - treatment with Nd: YAG laser (120 mJ of energy and intensity of frequency 15 Hz) and silane hot air dry. The resin cement that unite the specimens was cured for 40 seconds using the LED cure equipment (Radii-cal SDI). Then they were termomechanical cycled (60N, 1,000 thermical cycles and 24000 mechanical) and were submitted to the tensile test in a universal testing machine EMIC-2000. Data were tested for Dunnet ( α = 5 % ) and 3 ANOVA Way . The Er group showed higher tensile strength greater than the control group and the other groups, while the NdG group presented results of bond strength lower than the control group and the other surface treatments. The other groups did...O objetivo deste estudo foi avaliar o efeito de diferentes tratamentos de superfície na resistência de união entre a cerâmica de di-silicato de lítio IPS e.max Press (IvoclarVivadent, Liechtenstein) e o cimento resinoso Variolink II (Ivoclar Vivadent, Liechtenstein) quando submetidos a teste de tração. Para isso 330 bases tronco-cônicas de cerâmica de di-silicato de lítio foram aleatoriamente divididas em 11 grupos de acordo com o tratamento a ser realizado: C - grupo controle; J - Jateamento com óxido de alumínio (50 μm); JAr - Jateamento com óxido de alumínio (30 μm) e secagem do silano com ar quente; GEr - Revestimento da superfície com grafite e tratamento com laser Er:YAG(200 mJ de intensidade de energia e 10 Hz de frequência); GErAr – Revestimento da superfície com grafite, tratamento com laser Er:YAG (200 mJ de intensidade de energia e 10 Hz de frequência) e secagem do silano com ar quente; Er - Tratamento com laser Er:YAG (200 mJ de intensidade de energia e 10 Hz de freqüência); ErAr - Tratamento com laser Er:YAG (200 mJ de intensidade de energia e 10 Hz de frequência) e secagem do silano com ar quente; GNd – revestimento da superfície com grafite e tratamento com laser Nd:YAG (120 mJ de intensidade de energia e 15 Hz de frequência); GNdAr – Revestimento da superfície com grafite, tratamento com laser Nd:YAG (120 mJ de intensidade de energia e 15 Hz de frequência) e secagem do silano com ar quente; Nd – Tratamento com laser Nd:YAG (120 mJ de intensidade de energia e 15 Hz de frequência); NdAr – Tratamento com laser Nd:YAG (120 mJ de intensidade de energia e 15 Hz de frequência) e secagem do silano com ar quente. O cimento resinoso que uniu os espécimes foi fotoativado por 40 segundos utilizando o aparelho LED (Radii cal-SDI). Então, foi realizada a ciclagem termomecânica com carga de 60N, 1.000 ciclos termicos e 24000 mecânicos e o ensaio ..
    corecore