1,720,966 research outputs found
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Remote management of left ventricular device assisted patients
Ventricular Assist Devices (VADs) have been lately considered as an efficient destination therapy for heart disease, achieving remarkable survival scores. This paper presents an integrated end-to-end VAD patient architecture consisting of a web-based HL7 compatible Specialist Monitoring Application, an Android-based Patient Monitoring Application and a portable embedded Auto-Regulation Unit is described, delivering for the first time an interconnected solution that not only combines the characteristics of EHR systems and allows the efficient monitoring of patients' and VAD status, but also enables the remote control, configuration and auto-regulation of any VAD
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
An innovative adaptive control strategy for sensorized left ventricular assist devices
Nowadays advanced heart failure is mainly treated through heart transplantation. However, the low availability of donors makes the research of alternative therapies urgent. Continuous-flow left ventricular assist devices (LVADs) are going to assume a more significant role in assisting the failing heart. A recent challenge in clinical practice is the possibility to use LVAD as long-term therapy rather than as a bridge to transplantation. For this reason, more comfortable devices, able to dynamically adapt to the physiological cardiac demand in relation to the patient activity level, are needed in order to improve the life quality of patients with implants. Nevertheless, no control system has been developed yet for this purpose. This work proposes an innovative control strategy for a novel sensorized LVAD, based on the continuous collection of physical and functional parameters coming from implantable sensors and from the LVAD itself. Thanks to the proposed system, both the patient and the LVAD conditions are continuously monitored and the LVAD activity regulated accordingly. Specifically, a Proportional Integrative (PI) and a threshold control algorithms have been implemented, respectively based on flow and pressure feedbacks collected from the embedded sensors. To investigate the feasibility and applicability of this control strategy, an on-bench platform for LVADs sensing and monitoring has been developed and tested
A portable system for autoregulation and wireless control of sensorized left ventricular assist devices
End stage heart failure patients could benefit from left ventricular assist device (LVAD) implantation as bridge to heart transplantation or as destination therapy. However, LVAD suffers from several limitations, including the presence of a battery as power supply, the need for cabled connection from inside to outside the patient, and the lack of autonomous adaptation to the patient metabolic demand during daily activity. The authors, in this wide scenario, aim to contribute to advancement of the LVAD therapy by developing the hardware and the firmware of a portable autoregulation unit (ARU), able to fulfill the needs of sensorized VAD in terms of physic/physiological data storing, continuous monitoring, wireless control from the external environment and automatic adaptation to patient activities trough the implementation of autoregulation algorithms. Moreover, in order to answer the rules and safety requirements for implantable biomedical devices, a user control interface (UCI), was developed and associated to the ARU for an external manual safe control. The ARU and UCI functionalities and autoregulation algorithms have been successfully tested on bench and on animal, with a response time of 1 s for activating autoregulation algorithms. Animal experiments showed as the presence of the ARU do not affect the animal cardiovascular system, giving a proof of concept of its applicability in vivo
An Innovative Wireless Endoscopic Capsule With Spherical Shape
This paper aims to contribute to the advancement of the Wireless Capsule Endoscopy (WCE) field for ColoRectal Cancer (CRC) screening, by developing all electronic circuits to build an innovative wireless endoscopic capsule with a spherical shape, conceived to reduce the friction during its locomotion and thus improving patient’s acceptability. The proposed capsule embeds an image sensor with optics and Light Emitting Diodes (LEDs), a control unit with a telemetry module, an actuation system, a battery with a smart recharging circuit able to recharge in 20 minutes, a smart power-on circuit and a localization module. Everything is devised to fit in a small spherical shape with a diameter of 26 mm and a weight of 12.70 g. The authors present a description of the sub-modules involved in the capsule development, together with the firmware and hardware integration. In order to reduce the bandwidth for matching the specifications of the target commercial telemetry, the firmware interfacing of a custom encoder was performed, which is able to compress the incoming images with a negligible loss of information and occupying a number of Look Up-Tables (LUTs) less than 1780. As a preliminary work, a versatile Field Programmable Gate Arrays (FPGA) based demo-board system has been developed in order to test and optimize the functionalities and the performance of the single sub-modules and wireless vision chain system. This work allows to demonstrate the feasibility of a complex biomedical system, with severe constraints by highlighting the necessity to enhance the frame rate in the future
- …
