1,721,011 research outputs found
[Ultrasonography features of the diaphragmatic crura: normal anatomy and its variants].
To report the various US patterns of the diaphragmatic crura and the changes occurring during the different phases of respirations. The diaphragm has two US patterns: the central membranous part appears highly reflective while the posterior, upper and lateral muscular portions are hypoechoic and thick. The crura can sometimes appear quite bulky, which appearance is easy to misinterpret.We carried out a three-stage work: first we reviewed the US examinations of 23 subjects with a nodular appearance of the posteromedial bundles and studied the changes in thickness during respiration. Second we studied the diaphragmatic crura in 30 subjects aged 18-71 years, 15 men and 15 women. We used a commercially available unit with sector and convex 3.5 MHz probes at baseline and during breath hold and acquired multiple parasagittal and transverse scans. The crura thickness was measured in all patients. Last, we studied the diaphragmatic regions of 10 patients with right pleural effusion and of 8 patients with associated ascites and pleural effusion using 2.0-5.0 MHz convex phased-array transducers.We found focal thickening of the crura in 11 of 23 patients with US findings of diaphragmatic nodules, but only in deep inspiration. The thickening was 1.5-2.2 cm long and maximum thickness was 10 mm. In the other 12 subjects we found 9 small lobules in the right and 3 in the left crus. In the anatomic study, we observed a 3-band appearance of the diaphragmatic crura, probably referable to muscle bundles, in 30 subjects on sagittal images, in 12 on coronal images and in 28 on anterior transverse images. The diaphragmatic crura were identified in 26 subjects only. The left posterior crus was identified in 29 subjects on left coronal images and in 15 on anterior transverse images; it was demonstrated on anterior sagittal images in close proximity to the aorta in only 4 subjects. Right crus thickness, measured on sagittal scans, ranged 3-10 mm in deep inspiration and 1-4 mm in expiration while the left crus was 3-6 mm in inspiration and 1-2 mm in expiration. The length of the right crus, studied in the preaortic portion, ranged from 7 cm in deep inspiration to 9.7 cm in expiration while the left one was 6.5 to 8.8 cm. The right lateral diaphragmatic bundles were seen in 28 subjects only on repeated subcostal oblique scans and the the left ones in 11 subjects only. Finally the thin anterior bundles were shown on parasagittal images in 13 cases in the right side and in 2 in the left. A 2-band appearance of the diaphragm was seen in 10 patients with pleural effusion and in 8 patients with associated ascites. A single band was found only in the tendinous portion of the diaphragm.US is presently considered the imaging method of choice in the assessment of changes in thickness and length of the diaphragmatic crura. These structures have different US patterns and can sometimes appear quite bulky and thus be easily mistaken for other anatomic or abnormal structures; orthogonal scans may be required for the differential diagnosis
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
Fetal auditory responses to external sounds and mother's heart beat: detection improved by Independent Component Analysis.
In this paper, we present a magnetoencephalographic study of the fetal auditory response to external stimuli and to the sound of the mother's heartbeat. We describe how an ad hoc functional selection procedure allowed us to isolate the sources in the fetal brain responding to sounds only, after the application to the recorded data of a standard Independent Component Analysis algorithm. In our experiment, acoustic stimuli were delivered to twelve healthy women with uncomplicated pregnancies at a time between 36 and 40 weeks gestational age, with their fetuses in breech presentation. Ultrasound images allowed determination of the region over the women's abdomen nearest to the fetal head, over which both the acoustic stimulator and the MEG sensors were subsequently placed. In 8 out of the 12 cases, our analysis provided consistent evidence of a fetal response both to the mother's heartbeat and to the external auditory stimulation; both were characterized by a clear prominent component at around 200 ms latency, which is widely accepted as the marker of the fetal response to auditory stimuli
koamabayili/VECTRON-author-checklist: VECTRON author checklist
We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
Functional source separation and hand cortical representation for a brain-computer interface feature extraction.
A brain-computer interface (BCI) can be defined as any system that can track the person's intent which is embedded in his/her brain activity and, from it alone, translate the intention into commands of a computer. Among the brain signal monitoring systems best suited for this challenging task, electroencephalography (EEG) and magnetoencephalography (MEG) are the most realistic, since both are non-invasive, EEG is portable and MEG could provide more specific information that could be later exploited also through EEG signals. The first two BCI steps require set up of the appropriate experimental protocol while recording the brain signal and then to extract interesting features from the recorded cerebral activity. To provide information useful in these BCI stages, our aim is to provide an overview of a new procedure we recently developed, named functional source separation (FSS). As it comes from the blind source separation algorithms, it exploits the most valuable information provided by the electrophysiological techniques, i.e. the waveform signal properties, remaining blind to the biophysical nature of the signal sources. FSS returns the single trial source activity, estimates the time course of a neuronal pool along different experimental states on the basis of a specific functional requirement in a specific time period, and uses the simulated annealing as the optimization procedure allowing the exploit of functional constraints non-differentiable. Moreover, a minor section is included, devoted to information acquired by MEG in stroke patients, to guide BCI applications aiming at sustaining motor behaviour in these patients. Relevant BCI features - spatial and time-frequency properties - are in fact altered by a stroke in the regions devoted to hand control. Moreover, a method to investigate the relationship between sensory and motor hand cortical network activities is described, providing information useful to develop BCI feedback control systems. This review provides a description of the FSS technique, a promising tool for the BCI community for online electrophysiological feature extraction, and offers interesting information to develop BCI applications to sustain hand control in stroke patients
- …
