1,720,968 research outputs found
Liquid Chromatography/Tandem Mass Spectrometric Confirmatory Method for Determining Aflatoxin M1 in Cow Milk. Comparison Between Electrospray and Atmospheric Pressure Photoionization Sources
A liquid chromatography/electrospray (ESI)–tandem mass spectrometric method for the measurement of aflatoxin M1 (AFM1) in milk is described. Milk sample after protein precipitation with acetone was cleaned-up with a Carbograph-4 cartridge. Performances of the ESI source were compared with those of the atmospheric pressure photoionization source (APPI). Although a method quantification limit (MQL) of 6 ng/kg could be achieved operating with APPI source with respect to an MQL of 12 ng/kg with ESI, all the other performances being similar, then ESI was preferred as being more robust and widespread at present
Determination of type-B fumonisin mycotoxins in maize and maize-based products by LC/MS/MS using a QqQlinear ion trap mass spectrometer.
A sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for determining the type B fumonisin mycotoxins in corn-based foodstuffs is described. Fumonisins FB1 and FB2 were extracted from a 1 g sample by homogenization with acetonitrile/water (75:25, v/v, 50mmol/L formic acid, 25 mL final volume) and the extract was defatted on C-18 phase. Volumes of 5 mL of crude extracts were cleaned up on Carbograph-4 cartridges. The final solution was analyzed by HPLC with electrospray ionization mass spectrometry in positive ion mode using multiple reaction monitoring with a QqQ linear ion trap mass spectrometer. Recoveries for spiked corn-based foodstuffs ranged from 91-105% (RSD% less than or equal to 8%), and method detection limits were less than or equal to 2ng/g for FBI and less than or equal to 1 ng/g for FB2. Two different spiking levels were tested (5000 and 100 ng/g for FB1, 1000 and 20 ng/g for FB2). Quantitation was achieved by an external calibration procedure using matrix-matched standards, with diclofenac added post-cleanup as internal standard for the LC/MS/MS analyses. Calibration curves showed linearity in the concentration range 0.005-5ng/muL of final extract (0.992 less than or equal to R-2 less than or equal to 0.995). Two other fumonisins, FB3 and FB4, were identified in naturally contaminated samples of corn meal using an information-dependent acquisition protocol that looped three experiments, including neutral loss scan, enhanced resolution scan, and enhanced product ion scan. FB3 and FB4 quantitation was estimated as peak area ratios relative to the FB2 response in view of the lack of both standards. This work also includes an application of the present LC/MS/MS method to some maize and maize-based product samples (corn meal, cornflakes and popcorn) collected from Italian stores. FB1 and FB2 contamination levels exceeding the European Union recommendation were found in 8 out of 15 corn meal samples
On-line analysis of volatile chlorinated hydrocarbons in air by gas chromatography-mass spectrometry Improvements in preconcentration and injection steps
An analytical system composed of a cryofocusing trap injector device coupled to a gas chromatograph with mass spectrometric detection (CTI-GC-MS) specific for the on-line analysis in air of volatile chlorinated hydrocarbons (VCHCs) (dichloromethane; chloroform; 1,1,1-trichloroethane; tetrachloromethane; 1,1,2-trichloroethylene; tetrachloroethylene) was developed. The cryofocusing trap injector was the result of appropriate low cost modifications to an original purge-and-trap device to make it suitable for direct air analysis even in the case of only slightly contaminated air samples, such as those from remote zones. The CTI device can rapidly and easily be rearranged into the purge-and-trap allowing water and air analysis with the same apparatus. Air samples, collected in stainless steel canisters, were introduced directly into the CTI-GC-MS system to realize cryo-concentration (at -120 degrees C), thermal desorption (at 200 degrees C) and for the subsequent analysis of volatiles. The operating phases and conditions were customised and optimized. Recovery efficiency was optimized in terms of moisture removal, cold trap temperature and sampling mass flow. The injection of entrapped volatiles was realized through a direct transfer with high chromatographic reliability (capillary column-capillary column). These improvements allowed obtaining limits of detection (LODs) at least one order of magnitude lower than current LODs for the investigated substances. The method was successfully employed on real samples: air from urban and rural areas and air from remote zones such as Antarctica. (C) 2010 Elsevier B.V. All rights reserved
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
Development of a multiresidue method for analysis of major Fusarium mycotoxins in corn meal using liquid chromatography – tandem mass spectrometry
A sensitive and reliable liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method has been developed to determine, in a single run, eight trichothecenes, three fumonisins, zearalenone and alpha-zearalenol, in corn meal samples. LC and MS conditions were varied to find the best compromise in terms of sensitivity and separation. An acceptable compromise was obtained using a C-18 column thermostatted at 45 degrees C and a mobile phase gradient of methanol/water with 10 mmol/L formate buffer (pH 3.8). A multiple reaction monitoring program, in which fumonisins and trichothecenes (except nivalenol and deoxynivalenol) are acquired in positive ESI as [M+H](+) or [M+NH4](+), and all other compounds in negative ESI, was developed to match appropriate retention time windows. Sample preparation used a simple homogenization of the corn meal sample with acetonitrile/water (75:25, v/v) followed by extraction on a C-18 cartridge and clean-up on a cartridge containing graphitized carbon black. Method detection limits were in the range 2-14 ng/g, with the exception of nivalenol (27 ng/g), deoxynivalenol (40 ng/g) and 15-acetyldeoxynivalenol (30 ng/g). Good accuracy (recoveries 81-104%) and precision (RSD 4-11%) were obtained by performing calibration using a spiked analyte-free extract
- …
