1,720,971 research outputs found
Image-enhanced endoscopy for gastric preneoplastic conditions and neoplastic lesions. a systematic review and meta-analysis
BACKGROUND : Image-enhanced endoscopy (IEE) improves the accuracy of endoscopic diagnosis. We aimed to assess the value of IEE for gastric preneoplastic conditions and neoplastic lesions. METHODS : Medline and Embase were searched until December 2018. Studies allowing calculation of diagnostic measures were included. Risk of bias and applicability were assessed using QUADAS-2. Subgroup analysis was performed to explore heterogeneity. RESULTS : 44 studies met the inclusion criteria. For gastric intestinal metaplasia (GIM), narrow-band imaging (NBI) obtained a pooled sensitivity and specificity of 0.79 (95 %CI 0.72-0.85) and 0.91 (95 %CI 0.88-0.94) on per-patient basis; on per-biopsy basis, it was 0.84 (95 %CI 0.81-0.86) and 0.95 (95 %CI 0.94-0.96), respectively. Tubulovillous pattern was the most accurate marker to detect GIM and it was effectively assessed without high magnification. For dysplasia, NBI showed a pooled sensitivity and specificity of 0.87 (95 %CI 0.84-0.89) and 0.97 (95 %CI 0.97-0.98) on per-biopsy basis. The use of magnification improved the performance of NBI to characterize early gastric cancer (EGC), especially when the vessel plus surface (VS) classification was applied. Regarding other technologies, trimodal imaging also obtained a high accuracy for dysplasia (sensitivity 0.93 [95 %CI 0.85-0.98], specificity 0.98 [95 %CI 0.92-1.00]). For atrophic gastritis, no specific pattern was noted and none of the technologies reached good diagnostic yield. CONCLUSION : NBI is highly accurate for GIM and dysplasia. The presence of tubulovillous pattern and the VS classification seem to be useful to detect GIM and characterize EGC, respectively. These features should be used in current practice and to standardize endoscopic criteria for other technologies
A single vial is enough in the absence of endoscopic suspected intestinal metaplasia - less is more!
Background: For the correct staging of chronic atrophic gastritis (AG) and gastric intestinal metaplasia (GIM) at least 4 biopsies are recommended: 2 from the antrum/incisura and 2 from the body sent in two different vials. As virtual Chromoendoscopy with Narrow-Band-Imaging (NBI) is valid both in the diagnosis and staging of GIM, it is reasonable to question the need to separate biopsy samples in all procedures.
Aims: To evaluate if biopsy samples can be placed in the same vial without implications in the diagnosis and follow-up of the patient if during gastroscopy no typical endoscopic pattern of GIM with NBI is observed.
Methods: Multicentre prospective study of a consecutive sample of patients (n=183) submitted to gastroscopy using NBI with no superficial neoplastic lesions and no suggestive areas of GIM. Biopsies of both antrum/incisure and body were performed in all patients and samples were placed in the same vial for histologic assessment (according to OLGA and OLGIM), blinded to endoscopic features.
Results: In all patients, OLGA and OLGIM calculation was possible as the pathologists could distinguish biopsy samples from antrum/incisure from those of gastric body. The negative predictive value was 100% for advance stages of GIM or AG as 179 (98%) patients presented OLGIM 0 and only 4 (2%) presented OLGIM I. Regarding AG, 150 (82%) presented OLGA 0, 23 (13%) OLGA I and 10 (6%) OLGA II.
Conclusion: In the absence of a typical endoscopic pattern of GIM using NBI, it is effective to place biopsies’ specimens in the same vial (for Helicobacter pylori diagnosis) or even to abstain from biopsies as no single patient with significant changes seems to be missed. This change in clinical practice can have a significant impact on endoscopy costs
The role of generative language systems in increasing patient awareness of colon cancer screening
Introduction: This study aims to evaluate the effectiveness of ChatGPT (Chat Generative Pretrained Transformer) in answering patients' questions about colorectal cancer (CRC) screening, with the ultimate goal of enhancing patients' awareness and adherence to national screening programs. Methods: 15 questions on CRC screening were posed to ChatGPT4. The answers were rated by 20 gastroenterology experts and 20 non-experts in three domains (accuracy, completeness, and comprehensibility), and by 100 patients in three dichotomic domains (completeness, comprehensibility and trustability). Results: According to expert rating, the mean accuracy score was 4.8±1.1 on a scale ranging from 1 to 6. Men completeness score was 2.1±0.7 and mean comprehensibility score was 2.8±0.4 on a scale ranging from 1 to 3. Overall, accuracy (4.8±1.1 vs 5.6±0.7, P<0.001) and completeness (2.1±0.7 vs 2.7±0.4, P<0.001) scores were significantly lower for expert compared to non-expert, while comprehensibility was comparable among the two groups (2.7±0.4 vs 2.8±0.3, P=0.546). Patients rated all questions as complete, comprehensible and trustable in 97 to 100% of cases. Conclusions: ChatGPT shows good performance with the potential to enhance awareness about CRC and improve screening outcomes. Generative language systems may be further improved after proper training in accordance with scientific evidence and current guidelines
Reliability and accuracy of blue light imaging for staging of intestinal metaplasia in the stomach
Background and aims: An endoscopic grading system (EGGIM) using narrow-band-imaging (NBI) has shown to accurately identify patients with extensive gastric intestinal metaplasia (GIM). However, description with alternative systems such as blue-light-imaging (BLI) is limited. The aim of this study is to determine the reliability and accuracy of BLI-bright regarding diagnosis and staging of GIM.Methods: Reliability of WLE (white-light-endoscopy) and BLI among 6 observers was assessed using a standard classification based on endoscopic images. Afterward, 37 patients were submitted to gastroscopy using FujifilmEG-760Z and endoscopists had to determine EGGIM score using BLI-bright and to perform gastric biopsies for operative-link-of-gastric-intestinal-metaplasia (OLGIM) calculation. BLI-bright accuracy was determined by comparing results with prior EGGIM scores with NBI and current OLGIM.Results: Compared with WLE, the interobserver reliability between observers was substantially better with BLI (Weighted Kappa: 0.8 vs 0.41). There was an 84% agreement between BLI and NBI assessing EGGIM intervals (EGGIM 0-4vs5-10). The area under the ROC curve was 0.90 (95%CI: 0.79-1.0) using the cut-off of EGGIM > 4 to determine advanced GIM, with a sensitivity of 100% (95%CI: 88-100%).Discussion: BLI-bright is reliable for the diagnosis of gastric intestinal metaplasia and agrees significantly with NBI evaluation. Preliminary data suggests high sensitivity for identifying patients with increased risk of gastric cancer
Real-time assessment of H. pylori during the endoscopic assessment of individuals with gastric intestinal metaplasia. a possible way to reduce the burden of care
Objectives: The management of individuals with gastric intestinal metaplasia (GIM) includes biopsies for its staging and to diagnose Helicobacter pylori (Hp). Advanced-stage GIM can be estimated by endoscopy through EGGIM, and a new device permits the real-time assessment of ammonia for the identification of Hp infection. The aim of this study was to assess the simultaneous use of EGGIM and real-time assessment of ammonia to avoid biopsies and reduce the burden of care in clinical practice. Methods: A multicentre study involving 101 consecutively enrolled patients [52% male; 65(18-85) years]. During endoscopy, gastric juice was aspirated and analysed; EGGIM was determined in real-time. Targeted biopsies were performed and histopathological assessment was used as gold standard. Results: Advanced-stage GIM were detected in 14.9% of patients and Hp infection in 18.8%. EGGIM showed for advanced-stage GIM a sensitivity, specificity and NPV of 86.7%, 84.9% and 97.3%, whilst real-time assessment of ammonia, 83.3%, 78.2% and 95.4%, respectively. Gastric juice was insufficient in 5 (5.0%). Overall, 64 (67%) patients were correctly diagnosed by EGGIM and real-time assessment of ammonia. If the 47 (49%) patients negative to both assessments would have avoided biopsies, only 4 (4.2%) would have been missed: two with advanced-stage GIM and two with Hp infection. Conclusion: The combination of endoscopic assessment and real-time analysis of Hp allows the exclusion of advanced-stage GIM or Hp infection without the need of biopsies in a significant proportion of individuals. This may allow in specific situations to abstain from biopsies reducing the burden of care
Detection of gastric precancerous conditions in daily clinical practice: a nationwide survey
BACKGROUND: The burden of gastric precancerous conditions and factors associated with their detection have not been fully investigated in community-based settings. Little is known about adherence to Sydney system for histopathology of gastric biopsies.OBJECTIVE: We aimed to investigate what really happens in clinical practice with regard to the detection of gastric atrophy and intestinal metaplasia in dyspeptic patients.METHODS: We performed a nationwide survey of 979 consecutive patients (50-65 years old) with dyspeptic symptoms, examined at 24 gastrointestinal endoscopy units throughout Italy. Clinical information was collected from questionnaires; a standard bioptic mapping was performed in each unit, biopsies from each patient were analyzed by histopathology performed according to daily clinical practice in each local histopathology center.RESULTS: Separate descriptions of antral and corporal biopsies were included in 679 pathology reports (69%), whereas Sydney system was applied in 324 reports (33%). Gastric atrophy without intestinal metaplasia (GA) and gastric atrophy with intestinal metaplasia (GIM) were detected in 322 (33%) patients. The full adherence to Sydney system significantly increased the probability of detecting GIM (OR 9.6, 95% CI 5.5-16.7), GA (OR 1.92, 95% CI 1.07-3.44), and either of the conditions (OR 6.67, 95% CI 4.36-10.19).CONCLUSIONS: This nationwide survey showed that in one-third of dyspeptic patients, gastric precancerous conditions are detected. In daily routine practice, only 1/3 of histology reports were worked out adhering to Sydney system showing that international guidelines are poorly observed in clinical practice. This may represent a critical element for surveillance strategies for gastric cancer
Cost-utility analysis of colonoscopy or faecal immunochemical test for population-based organised colorectal cancer screening
Background: Organised programmes for colorectal cancer screening demand a high burden of medical and economic resources. The preferred methods are the faecal immunochemical test and primary colonoscopy. Objective: The purpose of this study was to perform an economic analysis and comparison between these tests in Europe. Methods: We used a Markov cost-utility analysis from a societal perspective comparing biennial faecal immunochemical test or colonoscopy every 10 years screening versus non-screening in Portugal. The population was screened, aged from 50–74 years, and efficacy was evaluated in quality-adjusted life years. For the base-case scenario, the faecal immunochemical test cost was €3 with 50% acceptance and colonoscopy cost was €397 with 38% acceptance. The threshold was set at €39,760/quality-adjusted life years and the primary outcome was the incremental cost-effectiveness ratio. Results: Screening by biennial faecal immunochemical test and primary colonoscopy every 10 years resulted in incremental utilities of 0.00151 quality-adjusted life years and 0.00185 quality-adjusted life years at additional costs of €4 and €191, respectively. The faecal immunochemical test was the most cost-effective option providing an incremental cost-effectiveness ratio of €2694/quality-adjusted life years versus €103,633/quality-adjusted life years for colonoscopy. Colonoscopy capacity would have to increase 1.3% for a faecal immunochemical test programme or 31% for colonoscopy. Conclusion: Biennial faecal immunochemical test screening is better than colonoscopy as it is cost-effective, allows more individuals to get screened, and provides a more rational use of the endoscopic capacity available
A multicenter prospective study of the real-time use of narrow-band imaging in the diagnosis of premalignant gastric conditions and lesions
Background and aim: Some studies suggest that narrow-band imaging (NBI) can be more accurate at diagnosing gastric intestinal metaplasia and dysplasia than white-light endoscopy (WLE) alone. We aimed to assess the real-time diagnostic validity of high resolution endoscopy with and without NBI in the diagnosis of gastric premalignant conditions and to derive a classification for endoscopic grading of gastric intestinal metaplasia (EGGIM). Methods: A multicenter prospective study (five centers: Portugal, Italy, Romania, UK, USA) was performed involving the systematic use of high resolution gastroscopes with image registry with and without NBI in a centralized informatics platform (available online). All users used the same NBI classification. Histologic result was considered the diagnostic gold standard. Results: A total of 238 patients and 1123 endoscopic biopsies were included. NBI globally increased diagnostic accuracy by 11 percentage points (NBI 94 % vs. WLE 83 %; P < 0.001) with no difference in the identification of Helicobacter pylori gastritis (73 % vs. 74 %). NBI increased sensitivity for the diagnosis of intestinal metaplasia significantly (87 % vs. 53 %; P < 0.001) and for the diagnosis of dysplasia (92 % vs. 74 %). The added benefit of NBI in terms of diagnostic accuracy was greater in OLGIM III/IV than in OLGIM I/II (25 percentage points vs. 15 percentage points, respectively; P < 0.001). The area under the curve (AUC) of the receiver operating characteristic (ROC) curve for EGGIM in the identification of extensive metaplasia was 0.98. Conclusions: In a real-time scenario, NBI demonstrates a high concordance with gastric histology, superior to WLE. Diagnostic accuracy higher than 90 % suggests that routine use of NBI allows targeted instead of random biopsy samples. EGGIM also permits immediate grading of intestinal metaplasia without biopsies and merits further investigation
- …
