8 research outputs found

    Effect of Core Stability Exercises and Treadmill Training on Balance in Children with Down Syndrome: Randomized Controlled Trial

    No full text
    Provide enhanced digital features for this article If you are an author of this publication and would like to provide additional enhanced digital features for your article then please contact [email protected]. The journal offers a range of additional features designed to increase visibility and readership. All features will be thoroughly peer reviewed to ensure the content is of the highest scientific standard and all features are marked as ‘peer reviewed’ to ensure readers are aware that the content has been reviewed to the same level as the articles they are being presented alongside. Moreover, all sponsorship and disclosure information is included to provide complete transparency and adherence to good publication practices. This ensures that however the content is reached the reader has a full understanding of its origin. No fees are charged for hosting additional open access content. Other enhanced features include, but are not limited to: • Slide decks • Videos and animations • Audio abstracts • Audio slides</p

    Optical soliton parameter dynamics by variational principle: parabolıc and dual–power laws (super–gaussian and super–sech pulses)

    No full text
    Abstract The current paper retrieves the optical soliton parameter dynamics that is considered with parabolic and dual—power laws of self—phase modulation structures. With linear chromatic dispersion and linear temporal evolution, the variational principle recovered the dynamical system of soliton parameters. Two specific forms of optical solitons are addressed in the paper which are super—Gaussian and super—sech pulses. These typically model RZ and NRZ types of pulses considered in telecommunications engineering. The special cases are naturally revealed when the parameter dictating the generalized nonlinearity is set to unity. The issue of soliton radiation has been tacitly disregarded to keep mathematics simple. The perturbation terms are also taken into account and the extended version of the Euler—Lagrange’s equation displays the extended dynamical system of these soliton parameters. The results naturally involved a range of special functions. © The Author(’s)

    Assessing the performance of a serological point-of-care test in measuring detectable antibodies against SARS-CoV-2

    No full text
    This study investigated the performance of a rapid point-of-care antibody test, the BioMedomics COVID-19 IgM/IgG Rapid Test, in comparison with a high-quality, validated, laboratory-based platform, the Roche Elecsys Anti-SARS-CoV-2 assay. Serological testing was conducted on 709 individuals. Concordance metrics were estimated. Logistic regression was used to assess associations with seropositivity. SARS-CoV-2 seroprevalence was 63.5% (450/709; 95% CI 59.8%-67.0%) using the BioMedomics assay and 71.9% (510/709; 95% CI 68.5%-75.2%) using the Elecsys assay. There were 60 discordant results between the two assays, all of which were seropositive in the Elecsys assay, but seronegative in the BioMedomics assay. Overall, positive, and negative percent agreements between the two assays were 91.5% (95% CI 89.2%-93.5%), 88.2% (95% CI 85.1%-90.9%), and 100% (95% CI 98.2%-100%), respectively, with a Cohen’s kappa of 0.81 (95% CI 0.78–0.84). Excluding specimens with lower (Elecsys) antibody titers, the agreement improved with overall, positive, and negative percent concordance of 94.4% (95% CI 92.3%-96.1%), 91.8% (95% CI 88.8%-94.3%), and 100% (95% CI 98.2%-100%), respectively, and a Cohen’s kappa of 0.88 (95% CI 0.85–0.90). Logistic regression confirmed better agreement with higher antibody titers. The BioMedomics COVID-19 IgM/IgG Rapid Test demonstrated good performance in measuring detectable antibodies against SARS-CoV-2, supporting the utility of such rapid point-of-care serological testing to guide the public health responses and vaccine prioritization. © 2022 Coyle et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited

    Exploring the cost-effectiveness of high versus low perioperative fraction of inspired oxygen in the prevention of surgical site infections among abdominal surgery patients in three low- and middle-income countries

    No full text
    Background: This study assessed the potential cost-effectiveness of high (80–100%) vs low (21–35%) fraction of inspired oxygen (FiO2) at preventing surgical site infections (SSIs) after abdominal surgery in Nigeria, India, and South Africa. Methods: Decision-analytic models were constructed using best available evidence sourced from unbundled data of an ongoing pilot trial assessing the effectiveness of high FiO2, published literature, and a cost survey in Nigeria, India, and South Africa. Effectiveness was measured as percentage of SSIs at 30 days after surgery, a healthcare perspective was adopted, and costs were reported in US dollars ().Results:HighFiO2maybecosteffective(cheaperandeffective).InNigeria,theaveragecostforhighFiO2was). Results: High FiO2 may be cost-effective (cheaper and effective). In Nigeria, the average cost for high FiO2 was 216 compared with 222forlowFiO2leadingtoa222 for low FiO2 leading to a −6 (95% confidence interval [CI]: −13to13 to −1) difference in costs. In India, the average cost for high FiO2 was 184comparedwith184 compared with 195 for low FiO2 leading to a −11(9511 (95% CI: −15 to −6)differenceincosts.InSouthAfrica,theaveragecostforhighFiO2was6) difference in costs. In South Africa, the average cost for high FiO2 was 1164 compared with 1257forlowFiO2leadingtoa1257 for low FiO2 leading to a −93 (95% CI: −132to132 to −65) difference in costs. The high FiO2 arm had few SSIs, 7.33% compared with 8.38% for low FiO2, leading to a −1.05 (95% CI: −1.14 to −0.90) percentage point reduction in SSIs. Conclusion: High FiO2 could be cost-effective at preventing SSIs in the three countries but further data from large clinical trials are required to confirm this. © 2023 The Author

    Classical fever of unknown origin in 21 countries with different economic development: an international ID-IRI study

    No full text
    © 2023, The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.Fever of unknown origin (FUO) is a serious challenge for physicians. The aim of the present study was to consider epidemiology and dynamics of FUO in countries with different economic development. The data of FUO patients hospitalized/followed between 1st July 2016 and 1st July 2021 were collected retrospectively and submitted from referral centers in 21 countries through ID-IRI clinical research platform. The countries were categorized into developing (low-income (LI) and lower middle-income (LMI) economies) and developed countries (upper middle-income (UMI) and high-income (HI) economies). This research included 788 patients. FUO diagnoses were as follows: infections (51.6%; n = 407), neoplasms (11.4%, n = 90), collagen vascular disorders (9.3%, n = 73), undiagnosed (20.1%, n = 158), miscellaneous diseases (7.7%, n = 60). The most common infections were tuberculosis (n = 45, 5.7%), brucellosis (n = 39, 4.9%), rickettsiosis (n = 23, 2.9%), HIV infection (n = 20, 2.5%), and typhoid fever (n = 13, 1.6%). Cardiovascular infections (n = 56, 7.1%) were the most common infectious syndromes. Only collagen vascular disorders were reported significantly more from developed countries (RR = 2.00, 95% CI: 1.19–3.38). FUO had similar characteristics in LI/LMI and UMI/HI countries including the portion of undiagnosed cases (OR, 95% CI; 0.87 (0.65–1.15)), death attributed to FUO (RR = 0.87, 95% CI: 0.65–1.15, p-value = 0.3355), and the mean duration until diagnosis (p = 0.9663). Various aspects of FUO cannot be determined by the economic development solely. Other development indices can be considered in future analyses. Physicians in different countries should be equally prepared for FUO patients

    Decoding the historical tale: COVID-19 impact on haematological malignancy patients—EPICOVIDEHA insights from 2020 to 2022

    No full text
    Background: The COVID-19 pandemic heightened risks for individuals with hematological malignancies due to compromised immune systems, leading to more severe outcomes and increased mortality. While interventions like vaccines, targeted antivirals, and monoclonal antibodies have been effective for the general population, their benefits for these patients may not be as pronounced. Methods: The EPICOVIDEHA registry (National Clinical Trials Identifier, NCT04733729) gathers COVID-19 data from hematological malignancy patients since the pandemic&apos;s start worldwide. It spans various global locations, allowing comprehensive analysis over the first three years (2020–2022). Findings: The EPICOVIDEHA registry collected data from January 2020 to December 2022, involving 8767 COVID-19 cases in hematological malignancy patients from 152 centers across 41 countries, with 42% being female. Over this period, there was a significant reduction in critical infections and an overall decrease in mortality from 29% to 4%. However, hospitalization, particularly in the ICU, remained associated with higher mortality rates. Factors contributing to increased mortality included age, multiple comorbidities, active malignancy at COVID-19 onset, pulmonary symptoms, and hospitalization. On the positive side, vaccination with one to two doses or three or more doses, as well as encountering COVID-19 in 2022, were associated with improved survival. Interpretation: Patients with hematological malignancies still face elevated risks, despite reductions in critical infections and overall mortality rates over time. Hospitalization, especially in ICUs, remains a significant concern. The study underscores the importance of vaccination and the timing of COVID-19 exposure in 2022 for enhanced survival in this patient group. Ongoing monitoring and targeted interventions are essential to support this vulnerable population, emphasizing the critical role of timely diagnosis and prompt treatment in preventing severe COVID-19 cases. Funding: Not applicable. © 2024 The Author(s

    International Nosocomial Infection Control Consortiu (INICC) report, data summary of 43 countries for 2007-2012. Device-associated module

    No full text
    We report the results of an International Nosocomial Infection Control Consortium (INICC) surveillance study from January 2007-December 2012 in 503 intensive care units (ICUs) in Latin America, Asia, Africa, and Europe. During the 6-year study using the Centers for Disease Control and Prevention's (CDC) U.S. National Healthcare Safety Network (NHSN) definitions for device-associated health care–associated infection (DA-HAI), we collected prospective data from 605,310 patients hospitalized in the INICC's ICUs for an aggregate of 3,338,396 days. Although device utilization in the INICC's ICUs was similar to that reported from ICUs in the U.S. in the CDC's NHSN, rates of device-associated nosocomial infection were higher in the ICUs of the INICC hospitals: the pooled rate of central line–associated bloodstream infection in the INICC's ICUs, 4.9 per 1,000 central line days, is nearly 5-fold higher than the 0.9 per 1,000 central line days reported from comparable U.S. ICUs. The overall rate of ventilator-associated pneumonia was also higher (16.8 vs 1.1 per 1,000 ventilator days) as was the rate of catheter-associated urinary tract infection (5.5 vs 1.3 per 1,000 catheter days). Frequencies of resistance of Pseudomonas isolates to amikacin (42.8% vs 10%) and imipenem (42.4% vs 26.1%) and Klebsiella pneumoniae isolates to ceftazidime (71.2% vs 28.8%) and imipenem (19.6% vs 12.8%) were also higher in the INICC's ICUs compared with the ICUs of the CDC's NHSN

    International Nosocomial Infection Control Consortiu (INICC) report, data summary of 43 countries for 2007-2012. Device-associated module

    No full text
    We report the results of an International Nosocomial Infection Control Consortium (INICC) surveillance study from January 2007-December 2012 in 503 intensive care units (ICUs) in Latin America, Asia, Africa, and Europe. During the 6-year study using the Centers for Disease Control and Prevention's (CDC) U.S. National Healthcare Safety Network (NHSN) definitions for device-associated health care-associated infection (DA-HAI), we collected prospective data from 605,310 patients hospitalized in the INICC's ICUs for an aggregate of 3,338,396 days. Although device utilization in the INICC's ICUs was similar to that reported from ICUs in the U.S. in the CDC's NHSN, rates of device-associated nosocomial infection were higher in the ICUs of the INICC hospitals: the pooled rate of central line-associated bloodstream infection in the INICC's ICUs, 4.9 per 1,000 central line days, is nearly 5-fold higher than the 0.9 per 1,000 central line days reported from comparable U. S. ICUs. The overall rate of ventilator-associated pneumonia was also higher (16.8 vs 1.1 per 1,000 ventilator days) as was the rate of catheter-associated urinary tract infection (5.5 vs 1.3 per 1,000 catheter days). Frequencies of resistance of Pseudomonas isolates to amikacin (42.8% vs 10%) and imipenem (42.4% vs 26.1%) and Klebsiella pneumoniae isolates to ceftazidime (71.2% vs 28.8%) and imipenem (19.6% vs 12.8%) were also higher in the INICC's ICUs compared with the ICUs of the CDC's NHSN. Copyright (C) 2014 by the Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved
    corecore