1,720,972 research outputs found
Controlling the Bioreceptor Spatial Distribution at the Nanoscale for Single Molecule Counting in Microwell Arrays
The ability to detect low concentrations of protein biomarkers is crucial for the early-stage detection of many diseases and therefore indispensable for improving diagnostic devices for healthcare. Here, we demonstrate that by integrating DNA nanotechnologies like DNA origami and aptamers, we can design innovative biosensing concepts for reproducible and sensitive detection of specific targets. DNA origami structures decorated with aptamers were studied as a novel tool to structure the biosensor surface with nanoscale precision in a digital detection bioassay, enabling control of the density, orientation, and accessibility of the bioreceptor to optimize the interaction between target and aptamer. DNA origami was used to control the spatial distribution of an in-house-generated aptamer on superparamagnetic microparticles, resulting in an origami-linked digital aptamer bioassay to detect the main peanut antigen Ara h1 with 2-fold improved signal-to-noise ratio and 15-fold improved limit of detection compared to a digital bioassay without DNA origami. Moreover, the sensitivity achieved was 4 orders of magnitude higher than commercially available and literature-reported enzyme-linked immunosorbent assay techniques. In conclusion, this novel and innovative approach to engineer biosensing interfaces will be of major interest to scientists and clinicians looking for new molecular insights and ultrasensitive detection of a broad range of targets, and, for the next generation of diagnostics.sponsorship: The authors gratefully acknowledge the financial support from KU Leuven (IOF/KP/12/002-Nanodiag; PDM/15/111 Devin Daems, OT 13/058) and Fund for Scientific Research (FWO G086114N, FWO-Flanders Postdoctoral Fellow Devin Daems 12U1618N, FWO-Flanders Research Stay Devin Daems V419416N, FWO-Flanders Doctoral grant Iene Rutten 1S30016N). A.J.T. acknowledges a Royal Society Wolfson Research Merit Award. (KU Leuven|IOF/KP/12/002-Nanodiag, KU Leuven|PDM/15/111 Devin Daems, KU Leuven|OT 13/058, Fund for Scientific Research (FWO)|G086114N, Fund for Scientific Research (FWO)|12U1618N, Fund for Scientific Research (FWO)|V419416N, Fund for Scientific Research (FWO)|1S30016N, Royal Society Wolfson Research Merit Award)status: Publishe
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
Highly Sensitive Multiplex Detection of Molecular Biomarkers Using Hybridization Chain Reaction in an Encoded Particle Microfluidic Platform
In the continuous combat against diseases, there is the need for tools that enable an improved diagnostic efficiency towards higher information density combined with reduced time-to-result and cost. Here, a novel fully integrated microfluidic platform, the Evalution™, is evaluated as a potential solution to this need. Encoded microparticles combined with channel-based microfluidics allow a fast, sensitive and simultaneous detection of several disease-related biomarkers. Since the binary code is represented by physically present holes, 210 different codes can be created that will not be altered by light or chemically induced degradation. Exploiting the unique features of this multiplex platform, hybridization chain reaction (HCR) is explored as a generic approach to reach the desired sensitivity. Compared to a non-amplified reference system, the sensitivity was drastically improved by a factor of 104, down to low fM LOD values. Depending on the HCR duration, the assay can be tuned for sensitivity or total assay time, as desired. The huge potential of this strategy was further demonstrated by the successful detection of a multiplex panel of six different nucleic acid targets including viruses and bacteria. The ability to not only discriminate these two categories but, with the same effort, also virus strains (human adenovirus and human bocavirus), virus subtypes (human adenovirus type B and D) and antibiotic-resistant bacteria (Streptococcus pneumonia), exemplifies the specificity of the developed approach. The effective, yet highly simplified, isothermal and protein-enzyme-free signal amplification tool reaches an LOD ranging from as low as 33 ± 4 to 151 ± 12 fM for the different targets. Moreover, direct detection in a clinically relevant sample matrix was verified, resulting in a detection limit of 309 ± 80 fM, approximating the low fM levels detectable with the gold standard analysis method, PCR, without the drawbacks related to protein enzymes, thermal cycling and elaborate sample preparation steps. The reported strategy can be directly transferred as a generic approach for the sensitive and specific detection of various target molecules in multiplex. In combination with the high-throughput capacity and reduced reagent consumption, the Evalution™ demonstrates immense potential in the next generation of diagnostic tools towards more personalized medicine.sponsorship: We gratefully acknowledge financial support from the Fund for Scientific Research (FWO-Flanders Doctoral grant Iene Rutten 1S30016N and FWO-Flanders Postdoctoral fellow Devin Daems 12U1618N). (Fund for Scientific Research (FWO-Flanders Doctoral grant)|1S30016N, Fund for Scientific Research (FWO-Flanders)|12U1618N)status: Published onlin
koamabayili/VECTRON-author-checklist: VECTRON author checklist
We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
Creasensor : SIMPLE technology for creatinine detection in plasma
The lab-on-a-chip (LOC) field has witnessed an excess of new technology concepts, especially for the point-of-care (POC) applications. However, only few concepts reached the POC market often because of challenging integration with pumping and detection systems as well as with complex biological assays. Recently, a new technology termed SIMPLE was introduced as a promising POC platform due to its features of being self-powered, autonomous in liquid manipulations, cost-effective and amenable to mass production. In this paper, we improved the SIMPLE design and fabrication and demonstrated for the first time that the SIMPLE platform can be successfully integrated with biological assays by quantifying creatinine, biomarker for chronic kidney disease, in plasma samples. To validate the robustness of the SIMPLE technology, we integrated a SIMPLE-based microfluidic cartridge with colorimetric read-out system into the benchtop Creasensor. This allowed us to perform on-field validation of the Creasensor in a single-blind study with 16 plasma samples, showing excellent agreement between measured and spiked creatinine concentrations (ICC: 0.97). Moreover, the range of clinically relevant concentrations (0.76–20 mg/dL), the sample volume (5 μL) and time-to-result of only 5 min matched the Creasensor performance with both lab based and POC benchmark technologies. This study demonstrated for the first time outstanding robustness of the SIMPLE in supporting the implementation of biological assays. The SIMPLE flexibility in liquid manipulation and compatibility with different sample matrices opens up numerous opportunities for implementing more complex assays and expanding its POC applications portfolio.sponsorship: The research leading to these results has received funding from the KU Leuven (PDM/17/093, C3 project 3E150475, C3 project C32/17/007) and the FWO-Flanders Postdoctoral Fellow Devin Daems 12U1618N. These results were obtained in the context of the SensUs 2016 competition (http://sensus.org/). (KU Leuven|PDM/17/093, KU Leuven|3E150475, KU Leuven|C32/17/007, FWO-Flanders Postdoctoral Fellow Devin Daems|12U1618N)status: Publishe
- …
