    Hemolysis detection accuracy on Stago sthemO 301

    No full text
    The findings of our study show that the novel Stago sthemO 301 coagulometer exhibits high accuracy detecting hemolysis when compared to the well established assay on the Roche COBAS c701 analyzer. The strong Spearman’s correlation coefficient reflects excellent concordance between the two assays, while the ROC curve analysis reveals an almost perfect diagnostic performance, with an AUC as high as 0.99. These results are especially important for hemostasis laboratories, where accurate detection of hemolysis is critical for integrity and reliability of coagulation test results

    Influence of In Vitro Acidification on APTT Measured With Two Different Reagents on Two Different Analyzers

    No full text
    We designed a study to evaluate whether in vitro–induced acidosis may influence APTT values using two different analyzers (with optical or mechanical clot detection) and two distinct reagents. The results of our study demonstrate that APTT values, measured with two distinct reagents on two different hemostasis analyzers, progressively increased as the sample pH was systematically reduced in vitro. This finding suggests that the prolonged APTT values might be at least partially attributable to an in vitro artifact rather than an in vivo metabolic effect influencing the coagulation pathway. Supporting this hypothesis is the observation that varying degrees of APTT prolongation depending on the specific reagent-analyzer combinations used. This indicates a potential reagent-specific sensitivity to pH changes, likely attributable to differences in clotting activators and phospholipid composition, which would otherwise suggest that measuring pH in samples with APTT prolongation before conducting additional, labor-intensive investigations may be a practical and efficient approach. Nevertheless, these findings underscore the need to consider pH as a critical preanalytical variable when interpreting APTT test results, as pH fluctuations may differentially affect assay outcomes depending on reagents and analyzers

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Get PDF
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Comparative evaluation of routine coagulation testing on Stago sthemO 301 and Werfen ACL TOP 750

    No full text
    Objectives: We performed a comparative evaluation of analytical performance between the novel bench-top Stago sthemO 301 hemostasis analyzer and the Werfen ACL TOP 750 coagulometer using routine plasma samples. Methods: A minimum of 100 fresh plasma samples per test were analyzed using both analytical systems. The tests included prothrombin time (PT) expressed as international normalized ratio (INR) and seconds (s), activated partial thromboplastin time (APTT) in ratio and seconds, fibrinogen, antithrombin and D-dimer. Clotting assays were performed using mechanical clot detection on sthemO and optical detection on ACL TOP. The comparative evaluation included the calculation of Spearman's correlation, Passing-Bablok regression and Bland-Altman plots. Results: Correlation coefficients ranged between 0.76 for APTT to 0.98 for PT-INR and D-dimer, indicating a generally acceptable/good agreement. The regression slopes varied from 0.82 for D-dimer to 1.17 for APTT-s. A significant bias was observed for all tests except antithrombin, with differences for sthemO ranging between -31 % for D-dimer and 13.7 % for PT-s. Conclusions: SthemO demonstrates acceptable global comparability with ACL TOP for routine coagulation testing. Nevertheless, reagent- and method-dependent bias has been observed, which highlight the need for additional harmonization efforts

    Variations on the Author

    Get PDF
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Get PDF
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Dispelling the Myths Behind First-author Citation Counts

    Get PDF
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Author Index

    No full text
    Nao informado

    koamabayili/VECTRON-author-checklist: VECTRON author checklist

    No full text
    We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
    corecore