1,721,046 research outputs found
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Dynamic optimization of thermal comfort and energy consumption, data-driven approach
Etant le secteur économique le plus énergivore, dans le cadre de la transition énergétique, le bâtiment présente un fort potentiel d’économie d’énergie. Les différentes réglementations thermiques et les normes ont fixé des objectifs très haut en termes de performance énergétique pour les bâtiments neufs ou rénovés. En ce qui concerne les bâtiments existants, l’optimisation du contrôle de leurs systèmes présente un levier important d’économie d’énergie. Le but de ce travail est de mettre en place une approche anticipative de contrôle des systèmes de chauffage des bâtiments modernes, basée sur les données. Cette approche comprend deux volets. Le premier volet propose un processus automatisé de développement de modèle prédictif capable d’estimer le comportement du bâtiment sur un horizon de 24 heures, en utilisant deux types de modèle ; un modèle linéaire (régression linéaire multiple) et un modèle non-linéaire (réseau de neurones artificiels). Le deuxième volet concerne l’utilisation d’un algorithme génétique pour l’identification de la stratégie de chauffage optimale permettant d’optimiser le confort thermique et la consommation énergétique du bâtiment. En se basant sur ces deux volets, la plateforme Smart Building control Platfrom (SBcP) a été mise en place. Pour valider cette plateforme, nous l’avons testé sur un bâtiment expérimental situé à Béthune (Pas de calais). Les résultats expérimentaux obtenus ont montré que le modèle de régression linéaire multiple considéré est capable de prédire la température intérieure avec une erreur quadratique moyenne (RMSE) autour de 1,6°C sur un horizon de 24 heures. Ces résultats ont été recueillis sur une durée de 21 jours allant du 3 mai au 24 mai 2021. Pendant cette période, le chauffage du bâtiment étudié a été piloté d’une façon anticipée en utilisant la SBcP. Malgré l’originalité du bâtiment étudié (dynamique très rapide à cause de son faible inertie) et la variation de la météo (intersaison), la SBcP a permis de garantir le confort thermique pendant 67% des heures d’occupations concernées en consommant le minimum possible d’énergie.Being the most energy-consuming economic sector, within the framework of the energy transition, the building industry presents a strong potential for energy savings. The various thermal regulations and standards have set very high objectives in terms of energy performance for new or renovated buildings. Regarding existing buildings, the optimization of the control of their systems presents an important saving energy leverage. The goal of this work is to develop a data-driven, anticipatory approach to control the heating systems of modern buildings. This approach includes two aspects. The first aspect proposes an automated process for developing a forecasting model able to forecast the behavior of the building over a 24-hour horizon, using two types of models: a linear model (multiple linear regression) and a non-linear model (neural network). The second aspect concerns the use of a genetic algorithm for the identification of the optimal heating strategy to optimize the thermal comfort and the energy consumption of the building. Based on these two aspects, the Smart Building control Platfrom (SBcP) was set up. To validate this platform, we have tested it on an experimental building located in Béthune (Pas de Calais). The experimental results obtained showed that the considered multiple linear regression model is able to predict the indoor temperature with a root-mean-square error (RMSE) around 1.6°C over a 24-hour horizon. These results were collected over a 21-day period from May 3 to May 24, 2021. During this period, the heating of the studied building was controlled in an anticipatory way using the SBcP. In spite of the originality of the studied building (very fast dynamics because of its low inertia) and the variation of the weather (inter-season), the SBcP made it possible to guarantee the thermal comfort during 67% of the hours of occupations concerned while consuming the minimum possible energy
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Induction infrared thermography applied for accessing reinforced concrete structures
Les enjeux économiques et sécuritaires majeurs portant sur l'évaluation de la pérennité des systèmes de précontrainte dans les ouvrages d'art conduisent au développement de nouvelles méthodes d'auscultation. Ces travaux représentent la contribution du LGCgE au programme national de recherche ANR ACTENA sur l'auscultation des câbles tendus non-accessibles. Les objectifs de ce travail sont la détermination du tracé des câbles de précontrainte et la détection des zones de défauts d'injection par thermographie infrarouge active. Le premier chapitre rappelle le contexte de cette étude, ainsi que les travaux antérieurs. L'introduction d'un mode de chauffage par induction conduit à une indétermination sur la présence éventuelle de défaut. Afin de lever cet artefact, le deuxième chapitre introduit une méthode originale de traitement fréquentiel des thermogrammes bruts basée sur une approche systémique dans le domaine fréquentiel. Une modélisation par éléments finis des spécimens expérimentaux permet d'étudier la diffusion et d'élaborer les paramètres expérimentaux. Le troisième chapitre expose les résultats expérimentaux obtenus sur trois spécimens de poutres. La procédure de traitement fréquentiel est appliquée aux séries de thermogrammes bruts obtenus. Les résultats sont discutés et mettent en avant l'intérêt des images de phase. Une approche quantitative est appliquée aux résultats de thermographie infrarouge dans le quatrième chapitre. La méthode d'inversion présentée permet la détermination de la diffusivité thermique du béton d'enrobage ainsi que son épaisseur.The economical and security aspects of the durability of the prestressed concrete construction works lead to develop new non destructive testing methods. This work was developed within the framework of the ANR ACTENA French research project. The main arms are to contribute to the localization of prestressed tendon ducts or rebars and also to the detection of the poor filling defects. The context of this study and previous works are described in the chapter I. The introduction of an inductor heating provides a non uniformity of the heating. In order to avoid any misinterpretation of thermograms, a frequential method based on transfer functions is proposed in chapter II. A 3D numerical model of the experimental specimens is performed by finite element method. Chapter III shows experimental results for three concrete beam specimens. The frequential procedure is applied to the raw thermograms. The results are discussed and highlighted the interest of phase images. A quantitative approach is applied to infrared thermographical results in the chapter IV. Finally, an inverse method is proposed and allowed to the determination of thermal diffusivity and the thickness of the cover concrete
Formalism of generalized thermal impedances. Application to the thermal characterization of building walls.
Le travail de recherche concerne l'aide au diagnostic énergétique de bâtiments par le développement d'outils et de procédures d'auscultation basés sur les transferts thermiques. L'objectif de ce travail est d'étudier le comportement thermique de parois constituant l'enveloppe de bâtiments, c'est à dire d'identifier les principales caractéristiques thermiques (conductivité thermique, chaleur volumique...) ainsi que les phénomènes de déphasage de sollicitations, en conditions de laboratoire et in situ. L'instrumentation est basée sur l'utilisation de capteurs fluxmétriques qui est spécifique et innovante, elle est associée à des procédures de traitement des données, dans le domaine fréquentiel (impédance thermique), basées à la fois sur des modèles de comportement et des études de sensibilités aux différents paramètres induits par procédure expérimentale. Au-delà des objectifs réglementaires, il est nécessaire de pouvoir estimer l'influence de la mise en œuvre des composants des parois mais également l'évolution de leurs caractéristiques thermiques en fonction des sollicitations micro-climatiques (évolution de leur teneur en eau). La caractérisation est basée sur des mesures de laboratoire, dites "classiques", sur des échantillons de matériaux de petites dimensions (quelques dm²), mais également sur des parois reconstituées de dimensions moyennes (quelques m²). Enfin les résultats sont comparés à des mesures réalisées in situ sur des bâtiments existants pendant une année complète en fonction des saisons.The research is relative to the diagnosis of building energy by developing tools and non destructive testing procedures based on heat transfer. The objective of this work is to study the thermal behavior of walls constituting the building envelope, namely to identify the main thermal characteristics (thermal conductivity, volumetric heat...) and the phenomena of phase stresses in laboratory and in situ conditions. The instrumentation is based on the use of heat flux sensor thaht is specific and innovative, it is associated with procedures for data processing in the frequency domain (thermal impedance), based both on models and studies sensitivities to different parameters induced by experimental procedure. Beyond the regulatory objectives, it is necessary to estimate the influence of the implementation of the components of the walls but also the evolution of their thermal characteristics depending on the micro-climate disturbance (changes in water content). The characterization is based on laboratory measurements, "classic" on samples of materials of small dimensions (few dm²), but also on walls reconstituted medium size (several square meters). Finally the results are compared with measurements made in situ on existing buildings for a full year with the seasons
Development of an inverse method for thermal characterization : application to building materials thermophysical and hydric properties estimation
Le but de ce travail est la caractérisation thermophysique de matériaux de construction solides et opaques (PVC, EPS, plâtre et béton) en laboratoire, avec une extension de la méthode vers des conditions in-situ (sable, paroi en béton cellulaire), et la mise en évidence de l’interaction des propriétés thermophysiques du matériau avec sa teneur en eau. Il repose sur l’étude numérique - via un modèle en différences finies - et expérimentale du transfert de chaleur par conduction. L’approche proposée consiste à envisager une distribution de capteurs de température répartis dans le sens du transfert dans une configuration expérimentale multicouche. Ces capteurs, des thermocouples permettent d’enregistrer les évolutions de températures aux différents points de mesure et d’extraire les caractéristiques thermiques du matériau dans chaque intervalle en les introduisant dans un schéma d’inversion. Le système instrumenté pourrait être sollicité de façon artificielle dans une application en laboratoire ou simplement par les échanges naturels avec son environnement dans le cas par exemple d’une paroi de bâtiment. Une progression dans la complexité des cas a été considérée. Dans un premier temps, une mise au point de la méthode sur un système multicouche constitué de matériaux homogènes, stationnaires et permettant d’identifier les paramètres thermiques d’un des composants. Par la suite, des matériaux de propriétés thermophysiques variables et évolutives avec pour objectif de proposer à plus long terme, un outil de suivi de propriétés thermiques et de teneur en eau des matériaux.The purpose of the actual work is to thermally characterize opaque solid building materials (PVC, EPS, Plaster and Concrete). First tests in laboratory tend next to be in situ conditions (sand, aerated concrete wall) where thermophysical properties and moisture content interactions are highlighted. It is based on conductive heat transfer numerical (finite difference method) and experimental study. The proposed approach aims to place thermocouples in a multilayer thickness in the heat transfer direction. They allow temperature measurement at different nodes of the material. The temperatures are incorporated in an inverse heat transfer process to estimate characteristics at each layer. The tested materials could be submitted to either artificial thermal excitation or natural excitation in the case of building wall for example. Progressive complexity of the studied cases is considered. In fact, the first studied cases concerns homogenous inert materials which the quasi constant thermophysical properties were estimated. Then, materials with variable characteristics were considered for a long term thermophysical properties and moisture content monitoring
Characterization, analysis and modelization of energy exchanges between a green wall and its environment
Ce travail de thèse vise à comprendre et analyser les échanges thermiques qui ont lieu entre un bâtiment et son environnement en présence de parois végétalisées « intensives ». Nous présentons dans ce manuscrit, une démarche numérique et expérimentale sur l’évaluation de l’incidence thermique de ces Murs Végétalisés (MV). Une plateforme constituée de trois prototypes identiques (3 mini-laboratoires thermiques) sous conditions climatiques réelles a été conçue et instrumentée. Dans un premier temps, deux écrans permettant une variation rapide et graduelle des taux de couvertures de 10 à 100% ont été ajoutés devant les prototypes. Ainsi, plusieurs séries de mesures ont été effectuées et des réductions significatives au niveau des températures et des flux de chaleur ont été enregistrées et interprétées. Cette démarche expérimentale avait pour premier objectif de mettre en oeuvre une occultation artificielle et donc maîtrisée. Un premier modèle a été développé sur la base de l’écriture des équations de bilan des échanges thermiques entre la paroi à occultation variable et son environnement climatique. Ce modèle confronté aux résultats fournis par l’expérimentation apermis de valider les approches théoriques au niveau des transferts radiatifs et convectifs. Dans un deuxième temps, le premier modèle qui a été développé dans ce travail a été adapté au cas d’une occultation « réelle » par de la végétation (lierre ou vigne vierge) puis validé expérimentalement. Il a été finalement implémenté dans un code de simulation thermique dynamique de bâtiment (TRNSYS), et ainsi l’incidence thermique des murs végétalisés simples (intensifs) a pu être évaluée à l’échelle réelle d’un bâtiment. Les résultats de simulations pour un climat tempéré montrent que la présence des plantes à feuilles persistantes a un impact négatif sur la demande énergétique hivernale. A l’inverse, en période estivale, les résultats montrent que les murs végétalisés ont un intérêt au niveau de la limitation des surchauffes. Leur présence réduit alors notablement la consommation énergétique nécessaire pour « climatiser » le bâtiment et améliore ainsi le confort thermique intérieur.This PhD thesis aims to understand and analyse the heat exchanges that occur between a building and its environment in the presence of intensive vegetated walls. In this manuscript, a numerical and experimental approach to evaluate the thermal impact of green walls is presented. A platform composed of three identical prototypes (3 thermal mini-laboratories) under real weather conditions has been designed and instrumented. As a first step, two screens permitting a rapid and gradual variation of coverage rate from 10 to 100% were added to the prototypes. Thus, several series of measurements were performed and significant reductions in temperature and heat flow were recorded and interpreted. The primary objective of this experimental approach was to implement an artificial shading and thus controlled. A first model was developed based on the writing of heat exchanges energy balance equations between the wall with variable coverage rate and its climatic environment. This model confronted to the experimental results allowed the validation of the theoreticalapproaches at the level of radiative and convective heat transfer. Secondly, the first model that was developed in this work has been adapted to the case of a "real" occultation by vegetation (Ivy or Virginia creeper) then validated experimentally.It was finally implemented in a dynamic thermal simulation code (TRNSYS), and thus the thermal impact of green walls were evaluated at the real scale of a building. Simulation results in a temperate climate show that the presence of evergreen plants has a negative impact on winter energy demand. Conversely, in summer, the results show that green walls have an interest in limiting overheating. Their presence significantly reduces energy consumption needed to cool the building and improves the indoor thermal comfort
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Active thermal applied in situ characterization of building walls
Les préoccupations environnementales actuelles visent à réduire les consommations énergétiques. Dans une démarche d’amélioration des bâtiments existants, l'étude du comportement thermique d’une paroi n'est pas aisée du fait de la méconnaissance de ses propriétés thermophysiques réelles. Ces paramètres sont pourtant prépondérants pour la phase d'optimisation économique des opérations de réhabilitation ou pour vérifier ses performances in situ. Il apparaît donc important de pouvoir caractériser les parois de bâtiment en place. Notre travail vise à développer une méthode de caractérisation thermique d’une paroi adaptée aux applications in situ basée sur une approche active. Le principe d'identification consiste à solliciter thermiquement une face d’accès en imposant un flux de chaleur sous forme d’un créneau et à étudier la réponse en température enregistrée par thermographie infrarouge sur l’autre face. A partir de signaux de flux et de températures mesurés aux limites de la paroi, les propriétés thermophysiques de la paroi seront estimées par méthode inverse. Nous nous sommes dans un premier temps intéressés aux parois homogènes. Le schéma d’inversion est construit autour d’un modèle numérique décrivant la réponse de la paroi suivant la méthode des différences finies en 1D. L’identification de la conductivité thermique et de la chaleur volumique de la paroi est réalisée en optimisant le groupement de paramètres qui permet de minimiser l’écart entre la température normalisée mesurée et la température normalisée simulée. Le coefficient d’échange surfacique global est également identifié à partir du même essai. Dans ce travail, la méthode a été appliquée à une paroi homogène en carreaux de plâtre mise en place au laboratoire. Elle a une épaisseur de 6.5 cm. Cette technique a été utilisée pour les parois multicouches de bâtiments. Les résultats issus de cette procédure d’inversion ont été comparés à des valeurs de référence obtenues à partir d’une procédure classique (NF EN 12664-méthode fluxmétrique). Une bonne concordance des résultats est obtenue. Une autre partie représente les essais in situ.Current environmental concerns are intended to reduce energy consumption. In a process of improving existing buildings, the study of the thermal behavior of a wall is not easy because of the ignorance of its real thermophysical properties. These parameters are yet to dominate the economic optimization phase of the rehabilitation or to check its performance in situ. It therefore appears important to characterize the walls of existing building. Our work aims to develop a method of thermal characterization of a wall suitable for in situ applications based on an active approach. The principle of identification is to apply a heat-face access by imposing a heat flux in the form of a pulse and to study the temperature response recorded by infrared thermography on the other side. From signal flow and temperature measured at the limits of the wall, the thermophysical properties of the wall will be estimated by inverse method. We are at present interested in homogeneous walls. The inversion scheme is built around a digital model describing the response of the wall following the finite difference method in 1D. The identification of the thermal conductivity and heat volume of the wall is achieved by optimizing the group of parameters which minimizes the normalized difference between the temperature measured and the temperature standard simulated. The overall Global exchange coefficient is also identified from the same test. In this work, the method was applied to a homogeneous wall tile plaster introduction to the laboratory. It has a thickness of 6.5 cm. This technique was used for multilayer walls of buildings. The results of this inversion procedure were compared with reference values obtained from a standard procedure (DIN EN 12664-flow meter methods). A good agreement is obtained. Another part is the in situ tests
- …
