1,720,959 research outputs found

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Get PDF
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Get PDF
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Methylene blue—current knowledge, fluorescent properties, and its future use

    Get PDF
    Methylene blue is a fluorescent dye discovered in 1876 and has since been used in different scientific fields. Only recently has methylene blue been used for intraoperative fluorescent imaging. Here, the authors review the emerging role of methylene blue, not only as a dye used in clinical practice, but also as a fluorophore in a surgical setting. We discuss the promising potential of methylene blue together with the challenges and limitations among specific surgical techniques. A literature review of PubMed and Medline was conducted based on the historical, current and future usage of methylene blue within the field of medicine. We reviewed not only the current usage of methylene blue, but we also tried to grasp its’ function as a fluorophore in five main domains. These domains include the near-infrared imaging visualization of ureters, parathyroid gland identification, pancreatic tumors imaging, detection of breast cancer tumor margins, as well as breast cancer sentinel node biopsy. Methylene blue is used in countless clinical procedures with a relatively low risk for patients. Usage of its fluorescent properties is still at an early stage and more pre-clinical, as well as clinical research, must be performed to fully understand its potentials and limitations

    Appropriate Similarity Measures for Author Cocitation Analysis

    Get PDF
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Fluorescence Imaging Using Methylene Blue Sentinel Lymph Node Biopsy in Melanoma

    No full text
    Introduction: Fluorescence imaging of sentinel node biopsy in melanoma is a novel method. Both indocyanine green (ICG) and methylene blue (MB) have fluorescent properties. The aim of this study was to present, for the first time in a clinical series of patients, the possible usage of MB as a fluorescent dye for sentinel node biopsy during surgery for melanoma. Material and methods: Twenty patients with skin melanoma, who were candidates for sentinel node biopsy were enrolled in our study. All patients underwent simultaneous use of standard nanocolloid and blue dye. Transcutaneous visualization of the sentinel node, visualization of lymphatic channels as well as sentinel node fluorescent visualization were all measured. We also performed calculations of Signal to Background ratios (SBR). Results: In 15% (3/20) of patients, the fluorescent sentinel node was visible through the skin. The median SBR for the sentinel node visualization by fluorescence was 3.15 (range, 2.7–3.5). Lymphatic channels were visible in lymphatic tissue via fluorescence before visualization by the naked eye in 4 patients (20%). The median SBR ratio was 3.69 (range, 2.7–4.2). Sentinel nodes were visible by fluorescence in 13 cases (65%). The median SBR ratio was 2.49 (range, 1.5–5.7). No factors were found to be associated with fluorescent MB visualization of a sentinel node during biopsy. Conclusion: This is the first clinical study presenting the usefulness of fluorescent sentinel node biopsy in melanoma patients using MB as a fluorophore. Further studies are necessary to provide methods for its’ clinical implementation. © The Author(s) 2022

    Methylene Blue Near-Infrared Fluorescence Imaging in Breast Cancer Sentinel Node Biopsy

    Get PDF
    Introduction: Fluorescence-based navigation for breast cancer sentinel node biopsy is a novel method that uses indocyanine green as a fluorophore. However, methylene blue (MB) also has some fluorescent properties. This study is the first in a clinical series presenting the possible use of MB as a fluorescent dye for the identification of sentinel nodes in breast sentinel node biopsy. Material and methods: Forty-nine patients with breast cancer who underwent sentinel node biopsy procedures were enrolled in the study. All patients underwent standard simultaneous injection of nanocolloid and MB. We visualized and assessed the sentinel nodes and the lymphatic channels transcutaneously, with and without fluorescence, and calculated the signal-to-background ratio (SBR). We also analyzed the corresponding fluorescence intensity of various dilutions of MB. Results: In twenty-three patients (46.9%), the location of the sentinel node, or the end of the lymphatic path, was visible transcutaneously. The median SBR for transcutaneous sentinel node location was 1.69 (range 1.66–4.35). Lymphatic channels were visible under fluorescence in 14 patients (28.6%) prior to visualization by the naked eye, with an average SBR of 2.01 (range 1.14–5.6). The sentinel node was visible under fluorescence in 25 patients (51%). The median SBR for sentinel node visualization with MB fluorescence was 2.54 (range 1.34–6.86). Sentinel nodes were visualized faster under fluorescence during sentinel node preparation. Factors associated with the rate of visualization included diabetes (p = 0.001), neoadjuvant chemotherapy (p = 0.003), and multifocality (p = 0.004). The best fluorescence was obtained using 40 μM (0.0128 mg/mL) MB, but we also observed a clinically relevant dilution range between 20 μM (0.0064 mg/mL) and 100 μM (0.032 mg/mL). Conclusions: For the first time, we propose the clinical usage of MB as a fluorophore for fluorescence-guided sentinel node biopsy in breast cancer patients. The quenching effect of the dye may be the reason for its poor detection rate. Our analysis of different concentrations of MB suggests a need for a detailed clinical analysis to highlight the practical usefulness of the dye

    Dispelling the Myths Behind First-author Citation Counts

    Get PDF
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Author Index

    No full text
    Nao informado

    koamabayili/VECTRON-author-checklist: VECTRON author checklist

    No full text
    We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
    corecore