1,720,960 research outputs found
Functionally distinct ERAP1 haplotype combinations distinguish individuals with ankylosing spondylitis
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
The effect of methotrexate on cardiovascular disease in patients with rheumatoid arthritis: a systematic literature review
Objectives: patients with RA have an increased prevalence of cardiovascular disease (CVD). This is due to traditional risk factors and the effects of chronic inflammation. MTX is the first-choice DMARD in RA. We performed a systematic literature review to determine whether MTX affects the risk of CVD in patients with RA.Methods: we searched Medline, Embase, Cochrane database, database of abstracts of reviews of effects, health technology assessment and Science Citation Index from 1980 to 2008. Conference proceedings (British Society of Rheumatology, ACR and EULAR) were searched from 2005 to 2008. Papers were included if they assessed the relationship between MTX use and CVD in patients with RA. Two reviewers independently assessed each title and abstract for relevance and quality.Results: a total of 2420 abstracts were identified, of which 18 fulfilled the inclusion criteria. Two studies assessed the relationship between MTX use and CVD mortality, one demonstrated a significant reduction in CVD mortality and the second a trend towards reduction. Five studies considered all-cause CVD morbidity. Four demonstrated a significant reduction in CVD morbidity and the fifth a trend towards reduction. MTX use in the year prior to the development of RA decreased the risk of CVD for 3–4 years. Four studies considered myocardial infarction, one demonstrated a decreased risk and three a trend towards decreased risk with MTX use.Conclusion: the current evidence suggests that MTX use is associated with a reduced risk of CVD events in patients with RA. This suggests that reducing the inflammation in RA using MTX not only improves disease-specific outcomes but may also reduce collateral damage such as atherosclerosi
Effective measurement of knee alignment using AP knee radiographs
The gold standard for measuring knee alignment is mechanical axis determined using full-limb radiographs (FLR). Measurement of joint alignment using antero-posterior (AP) knee radiographs is more accessible, economical and involves less radiation exposure to the patient compared with using full-limb radiographs. The aim of this study was to compare and assess the reproducibility of knee joint axial alignment on full-limb radiographs and conventional AP knee radiographs.
Knee alignment was measured in 40 subjects (80 knees) from the TwinsUK registry. Measurement of mechanical knee alignment was from FLR, and anatomic knee alignment from weight-bearing AP knee radiographs. Reproducibility was assessed by intra-class correlation coefficients and kappa statistics. Reproducibility of knee alignment for both methods was good, with intra-observer ICC's of 0.99 for both FLR
and AP radiographs. The mean alignment angle on FLR was 178.9° (SD 2.1, range 173–183°), and 179.0° (SD 2.1, range 173–185°) on AP films. 58.8% of knees on FLR and 66.3% on AP films were of varus alignment. Good correlations were seen between results for FLR and AP radiographs, with ICC ranging from 0.87–0.92 for left and right knees, and kappa statistics of 0.65–0.74. Standard AP knee radiographs can be used to measure knee alignment with good reproducibility, and
provide comparable results to those obtained from FLR. This will facilitate measurement of knee alignment in existing cohort studies to assess malalignment as a risk factor of incident OA, and in clinical practice
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
koamabayili/VECTRON-author-checklist: VECTRON author checklist
We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
- …
