1,720,959 research outputs found
Primitive pure signet-ring cell intestinal type adenocarcinoma of the sino-nasal tract: an extremely rare entity
Praja2 expression in non-invasive and muscle invasive urothelial carcinoma of the bladder
Impact of different peak tube voltage settings on adrenal adenomas attenuation at unenhanced CT
Objectives: To assess the influence of peak tube voltage peak setting on adrenal adenomas (AA) attenuation on unenhanced abdominal CT. Materials and methods: IRB-approved retrospective observational cohort study. We included 89 patients with imaging-defined AAs with shortest diameter > 6 mm who underwent two or more unenhanced abdominal CTs using at least two different peak tube voltage settings. Two readers independently measured adenoma attenuation on different CT acquisitions by drawing a round ROI on 3 mm thick axial MPR reconstructions encompassing at least 2/3 of the lesion's surface. The mean of the values measured by the two readers was used for further analysis. Interobserver variability was assessed (Intraclass Correlation Coefficient). Attenuation values measured on 100, 110 and 140 kVp acquisitions were compared with standard 120 kVp ones (Bland-Altman analysis). Results: We included 275 unenhanced abdominal CTs (3.1 ± 0.9/patient) in image analysis; 131 acquired at 120 kVp, 65 at 100 kVp, 59 at 110 kVp, and 20 at 140 kVp. 107 lesions were detected in 89 patients (1-4/patient), with a mean maximum diameter of 17 ± 6 mm. Interobserver agreement in attenuation measurement was excellent (ICC: 0.95, CI (92-97)). Median adenoma attenuation was significantly lower on 100 kVp images than on 120 kVp ones (-1 HU, IQR (-5 to 3.6), vs, 2.5 HU, IQR (-1.5 to 8.5); p < 0.001) whereas we didn't find statistically significant differences in adenoma attenuation between 110 kVp or 140 kVp and 120 kVp ones. Conclusion: AA attenuation is significantly lower on unenhanced CT scans acquired at 100 kVp than on those acquired at "standard" 120 kVp. Clinical relevance statement: AA attenuation is significantly lower at 100 kVp in comparison to 120 kVp. This might be exploited to increase unenhanced CT sensitivity in adenoma characterisation, but further studies including non-adenoma lesions are mandatory to confirm this hypothesis. Key points: CT scans are often acquired using peak tube voltage settings different from the "standard" 120 kVp. AA attenuation varies if CT scans are acquired using different tube peak voltage settings. At 100 kVp AAs show a significantly lower attenuation than at 120 kVp
Cytopathology practice during the COVID‐19 postlockdown: An Italian experience
During the current coronavirus disease 2019 (COVID-19) pandemic, the cytopathology workload has decreased remarkably worldwide as all screening and elective procedures have been postponed to prioritize the clinical management of patients at high oncological risk. In the current study, the authors provide data on the lasting impact of COVID-19 on cytopathology practice during the initial phases of the Italian postlockdown period
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
- …
