1,721,032 research outputs found

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Full text link
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Dispelling the Myths Behind First-author Citation Counts

    Full text link
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Author Index

    No full text
    Nao informado

    Hemodynamics and stresses in numerical simulations of the thoracic aorta: Stochastic sensitivity analysis to inlet flow-rate waveform

    No full text
    Numerical simulations of the blood flow inside a patient-specific thoracic aorta in presence of an aneurysm are considered. We focus on the impact on the numerical predictions of the inlet flow-rate waveform. First, the results obtained by using an idealized and a MRI-measured flow-rate waveform are compared. The measured boundary condition produces significantly higher wall shear stresses than those obtained in the idealized case. Discrepancies are reduced but they are still present even if the idealized inlet waveform is rescaled in order to match the stroke volume. This motivates a systematic sensitivity analysis of numerical predictions to the shape of the inlet flow-rate waveform that is carried out in the second part of the paper. Two parameters are selected to describe the inlet waveform: the stroke volume and the period of the cardiac cycle. A stochastic approach based on the generalized Polynomial Chaos (gPC) approach, in which continuous response surfaces of the quantities of interest in the parameter space can be obtained from a limited number of simulations, is used. For both selected uncertain parameters, we use beta PDFs reproducing clinical data. The two selected input parameters appear to have a significant influence on wall shear stresses as well as on the velocity distribution in vessel regions characterized by large curvature. This confirms the need of using patient-specific inlet conditions to obtain reliable hemodynamic predictions

    Impact of the Spatial Velocity Inlet Distribution on the Hemodynamics of the Thoracic Aorta

    No full text
    The impact of the distribution in space of the inlet velocity in the numerical simulations of the hemodynamics in the thoracic aorta is systematically investigated. A real healthy aorta geometry, for which in-vivo measurements are available, is considered. The distribution is modeled through a truncated cone shape, which is a suitable approximation of the real one downstream of a trileaflet aortic valve during the systolic part of the cardiac cycle. The ratio between the upper and the lower base of the truncated cone and the position of the center of the upper base are selected as uncertain parameters. A stochastic approach is chosen, based on the generalized Polynomial Chaos expansion, to obtain accurate response surfaces of the quantities of interest in the parameter space. The selected parameters influence the velocity distribution in the ascending aorta. Consequently, effects on the wall shear stress are observed, confirming the need to use patient-specific inlet conditions if interested in the hemodynamics of this region. The surface base ratio is globally the most important parameter. Conversely, the impact on the velocity and wall shear stress in the aortic arch and descending aorta is almost negligible

    koamabayili/VECTRON-author-checklist: VECTRON author checklist

    No full text
    We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used

    A Hybrid Mock Circulatory Loop for Fluid Dynamic Characterization of 3D Anatomical Phantoms

    No full text
    Goal: This work presents the development of a Hybrid Mock Circulatory Loop (HMCL) to simulate hemodynamics at patient-specific level in terms of both 3D geometry and inlet/outlet boundary conditions. Methods: Clinical data have been processed to define the morphological and functional patient-specific settings. A piston pump is used to impose a parametric flow rate profile at the inlet of the hemodynamic circuit. In order to guarantee the physiological pressure and flow conditions, a specific hybrid chamber system including a real-time control has been designed and implemented. The developed system was validated firstly in a single outlet branch model and, secondly, on a 3D printed patient-specific multi-branch phantom. Finally, for the 3D phantom, the outlet flow profiles were compared with the corresponding in-vivo flow data. Results: Results showed that the root mean squared error between the prescribed setpoint and the measured pressures was always below 3 mmHg (about 2.5%) for all cases. The obtained flow profiles for the patient-specific model were in agreement with the related functional in-vivo data. Significance: The capability to reproduce physiological hemodynamics condition, with high-fidelity, plays a significant role in the cardiovascular research. The developed platform can be used to assess the performances of cardiovascular devices, to validate numerical simulations, and to test imaging systems
    corecore