1,720,967 research outputs found

    Research of correlations between NDT and DT to assess mechanical properties of a soft stone in ancient masonry

    No full text
    A deep knowledge of the physical and mechanical properties of the constituent materials of ancient masonries is of crucial importance in the choice of the proper intervention technique. In case of historical buildings sustainable diagnostic procedures responding to the conservation constraints, should have the lowest degree of intrusion and the fullest respect for their physical integrity. The sample’s extraction from existing structures for laboratory tests is one of the major problems in the field of diagnosis of ancient buildings and this has moved the scientific community to propose alternative non-destructive techniques to evaluate the mechanical and physical properties of the building stones. In the present work non-destructive and destructive tests have been investigated as tools for assessing the compressive strength of “Lecce stone”, a soft calcarenitic stone used as traditional building materials in the Southern Italy. Ultrasonic pulse velocity (UPV), Schmidt hammer test and compressive tests on microcores have been compared with mechanical destructive tests on cubes in order to found correlations between the results. The final aim is to assess the reliability of the non-destructive investigated methods in describing the mechanical performance of the stone, reducing the use of destructive analyses on masonries

    Ultrasonic pulse velocity test for non-destructive investigations of historical masonries: an experimental study of the effect of frequency and applied load on the response of a limestone

    No full text
    The ultrasonic pulse velocity (UPV) method can be conveniently used for non-destructive testing of physical–mechanical properties of the stones within historical masonry, as well as to check the state of damage and microcracking. Before to proceed with in situ measurements, it is important to assess the contribution that both intrinsic characteristics of the stones and external factors may give to the ultrasonic response. In this work the effect of different wave frequencies, sample geometry and application of a compression load on the response of a natural stone to UPV test has been investigated. An extensive experimental campaign in laboratory conditions was carried out on a soft limestone, used in the historical building heritage of the Southern Italy. A negligible UPV dispersion was found at the used frequencies of 1 MHz, 120 and 55 kHz when a compression load was not applied; the measured velocities were found to be influenced by the stone inhomogeneity rather than by the sample size. They showed a slight decrease and still negligible dispersion under load up to the visible damage. Dispersion increased with the cracking progression. This indicates that enhanced capability of UPV, in checking material quality and damage conditions, can be obtained by combining the use of different wave frequencies

    Ultrasonic pulse velocity for the evaluation of physical and mechanical properties of a highly porous building limestone

    No full text
    UPV as non-destructive technique can effectively contribute to the low invasive in situ analysis and diagnosis of masonry elements related to the conservation, rehabilitation and strengthening of the built heritage. The use of non-destructive and non-invasive techniques brings all the times many advantages in diagnostic activities on pre-existing buildings in terms of sustainability; moreover, it is a strong necessity with respect to the conservation constraints when dealing with the historical-architectural heritage. In this work laboratory experiments were carried out to investigate the effectiveness of ultrasonic pulse velocity (UPV) in evaluating physical and mechanical properties of Lecce stone, a soft and porous building limestone. UPV and selected physical-mechanical parameters such as density and uniaxial compressive strength (UCS) were determined. Factors such as anisotropy and water presence that induce variations on the ultrasonic velocity were also assessed. Correlations between the analysed parameters are presented and discussed. The presence of water greatly affected the values of the analysed parameters, leading to a decrease of UPV and to a strong reduction of the compressive strength. A discussion of the role of the water on these results is provided. Regression analysis showed a reliable linear correlation between UPV and compressive strength, which allows a reasonable estimation of the strength of Lecce stone by means of non-destructive testing methods such as the ultrasonic wave velocity. Low correlation between UPV and density was found, suggesting that other factors than density, related to the fabric and composition, also influence the response of the selected stone to the UPV. They have no influence on the UCS, that instead showed to be highly correlated with the packing density

    Assessing the reliability of non-destructive and moderately invasive techniques for the evaluation of uniaxial compressive strength of stone masonry units

    No full text
    In this work Ultrasonic Pulse Velocity (UPV), Schmidt Hammer Rebound (SHR) test and strength assessment on microcores (UCSm) and standard cubic samples (UCSc) were used to detect the uniaxial compressive strength of stone masonry units. The analysis of the variability of the measurements allowed to investigate the significance of each test to differentiate the masonry blocks. The latter was evaluated by a Variability Index (VI), as the ratio between the variances at block scale and among the blocks. VI was found higher for UCSc and UPV than for UCSm and SHR measurements. A regression analysis aimed to the correlation of uniaxial compressive strengths evaluated by conventional destructive test on stone cubes with the other test results. The findings showed a good linear correlation among UCSc and UPV values (R2 = 0.83), thus supporting the reliability of UPV to screen the masonry units and to estimate their uniaxial compressive strength. The correlation of UCSc with UCSm was reasonable (R2 = 0.76), while it was low with SHR results; some limits related to the use of SHR and UCSm tests are also discussed

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Full text link
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
    corecore