1,720,962 research outputs found

    LigaSure vessel sealing system in laparoscopic Palomo varicocele ligation in childrenand adolescents.

    No full text
    Purpose: We review our experience with laparoscopic Palomo varicocele ligation using the LigaSure device in children and adolescents. Materials and Methods: Between June 2003 and December 2004, 25 varicoceles were treated by laparoscopic Palomo varicocele ligation using LigaSure vascular sealing. Patient ages ranged from 10 to 19 years (mean, 14.5 years). Indications for surgery included grade II III varicocele or ipsi-lateral testicular hypotrophy. One patient was affected by recurrent contralateral inguinal hernia and 2 presented with an ipsilateral patent processus vaginalis. We placed a 5-mm umbilical port for access, and kept pneumoperitoneum below 15 mm Hg. Under laparoscopic guidance, two addi- tional ports of 3 and 5 mm were inserted in the lower right and left quadrants, respectively. Once the vessels were isolated, the vascular sealant was applied 3-4 times to ensure coagulation of the spermatic vessels; the vessels were then divided with laparoscopic 5-mm scissors. Inguinal hernia and patent processus vaginalis were treated according to Schier’s technique. All procedures were performed in our day surgery facility. Results; Mean operative time was 18 minutes, which is significantly less than the time required in a similar group of 12 patients who underwent laparoscopic clip ligation. There were no periop- erative complications. Eleven of 16 patients recovered testicular size. Two patients had postopera-tive hydrocele: the first was treated successfully with scrotal aspiration, while the other patient re-quired scrotal hydrocelectomy. Conclusion: Laparoscopic Palomo varicocele sealing can be performed safely and rapidly and is highly successful in correcting varicoceles in young males. We also found it to be the ideal technique to correct the associated inguinal hernia or patent processus vaginali

    UNEXPECTED FINDING OF LAPAROSCOPIC APPENDECTOMY: APPENDIX MALT LYMPHOMA IN CHILDREN

    No full text
    Mucosa-associated lymphoid tissue (MALT) lymphomas comprise a group of indolent B-cell non-Hodgkin lymphomas (NHL), which are rare in pediatric age. The clinical presentation of MALT lymphomas varies according to the location of the lymphoma. We report on a case of MALT lymphoma involving the appendix in a 6-year-old girl. A 6-year-old girl was referred to our institution in May 2005 with a diagnosis of appendicitis. The abdominal ultrasound showed slight effusion in the pelvic fossa. The patient underwent laparoscopic appendectomy using the three-trocar technique. The appendix appeared moderately hyperaemic with slight enlargement of the two-thirds of the distal portion. The postoperative course was uneventful and the girl was discharged on day 1 without any complication. The morphological and immunohistochemical examination showed typical findings of low-grade MALT lymphoma (positivity for CD20, no immunostaing for CD5 and CD10, positivity for anti-k light chain and low positivity for Ki-67). Further extensive examinations (abdominal MRI, gastroscopy, colonscopy and capsule endoscopy of the ileum) revealed that the lymphoma was limited to the distal two-third of the appendix (stage IA) and was not associated with any specific infection. At a recent follow-up the patients appeared to be doing well. Appendiceal MALToma is a rather uncommon pathology and, to our knowledge, there is only one report of appendiceal intussusception associated with appendiceal maltoma. According to our experience, lowgrade MALToma can be managed by simple appendectomy. The histological examination should be the rule whenever an appendectomy is performed in children

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Get PDF
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Get PDF
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Get PDF
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
    corecore