1,721,025 research outputs found
Titration of tidal volume and induced hypercapnia in acute respiratory distress syndrome
Mechanical ventilation may promote overdistension-induced pulmonary lesions in patients with acute respiratory distress syndrome (ARDS). The static pressure-volume (P-V) curve of the respiratory system can be used to determine the lung volume and corresponding static airway pressure at which lung compliance begins to diminish (the upper inflection point, or UIP). This fall in compliance may indicate overdistension of lung units. We prospectively studied 42 patients receiving mechanical ventilation with an FIO2 of 0.5 or more for at least 24 h. According to the Lung Injury Score (LIS), 25 patients were classified as having ARDS (LIS > 2.5), while 17 patients constituted a non-ARDS control group. The P-V curve was obtained every 2 d. Mechanical ventilation initially used standard settings (volume-control mode, a positive end-expiratory pressure [PEEP] adjusted to the lower inflection point on the P-V curve, and a tidal volume [VT] of 10 ml/kg). The end-inspiratory plateau pressure (Pplat) was compared to the UIP, and VT was lowered when the Pplat was above the UIP. In the range of lung volume studied on the P-V curves (up to 1600 ml), a UIP could be shown in only one control patient (at 23 cm H2O). By contrast, a UIP was present on the P-V curve obtained from all patients with ARDS, corresponding to a mean airway pressure of 26 +/- 6 cm H2O, a lung volume of 850 +/- 200 ml above functional residual capacity and 610 +/- 235 ml above PEEP.(ABSTRACT TRUNCATED AT 250 WORDS
Impact of mild hypoxemia on renal function and renal resistive index during mechanical ventilation
RATIONALE: Short-term hypoxemia affects diuresis and natriuresis in healthy individuals. No data are available on the impact of the mild hypoxemia levels usually tolerated in critically ill patients receiving mechanical ventilation.
OBJECTIVES: To assess the renal effects of mild hypoxemia during mechanical ventilation for acute lung injury (ALI).
METHODS: Prospective, physiological study in 12 mechanically ventilated patients with ALI. Patients were studied at baseline with an arterial saturation (SaO(2)) of 96% [94-98] then a comparison was performed between SaO(2) values of 88-90% (mild hypoxemia) and 98-99% (high oxygenation).
MAIN RESULTS: FiO(2) was set at 0.25 [0.23-0.32] and 0.7 [0.63-0.8], respectively, to obtain SaO(2) of 89 [89-90] and 99% [98-99]. Hemodynamic or respiratory parameters were not significantly affected by FiO(2) levels. Compared with high oxygenation level, mild hypoxemia using low FiO(2) was associated with increase in diuresis (median [interquartile range], 67 [55-105] vs. 55 [45-60] ml/h; P = 0.003) and in doppler-based renal resistive index (RI) (0.78 [0.66-0.85] vs. 0.72 [0.60-0.78]; P = 0.003). The 2-h calculated creatinine clearance also increased (63 [46-103] vs. 35 [30-85] ml/min; P = 0.005) without change in urinary creatinine (P = 0.13). No significant change in natriuresis was observed. Half of the patients were under norepinephrine infusion and the renal response did not differ according to the presence of vasopressors.
CONCLUSION: In patients with ALI, mild hypoxemia related to short-term low FiO(2) induce increases in diuresis and in renal RI. This latter point suggests intra-renal mechanisms that need to be further investigated
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
koamabayili/VECTRON-author-checklist: VECTRON author checklist
We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
Author-wise bibliometric analysis based on entropy.
Author-wise bibliometric analysis based on entropy.</p
- …
