1,721,130 research outputs found
Collisional cooled Ps emitted into vacuum from silica-based porous materials: Experiment to measure the Ps cooling time
In recent experiments on positronium time of flight (Ps-TOF) we have studied emission of cooled and thermalized Ps into vacuum from oxidized nanochannels synthetized in silicon. Ps cools down through collisions with the walls of the channels before exiting into vacuum. An important unknown parameter in the Ps-TOF measurements is the permanence time in the medium, i.e. the Ps cooling time before emission into vacuum. In this paper we describe an experiment that allows us to estimate the cooling time of Ps by analyzing the Ps-TOF spectra of cool Ps at three different distances from the sample
Positronium cooling at cryogenic temperature for advanced experiments
New Ps spectroscopy measurements, formation of antihydrogen for antimatter-matter comparison experiments, production of Ps beams require the efficient production of cooled positronium in vacuum. At present the most efficient positron-positronium converters are silica based ordered or disordered porous materials, in which formed Ps decreases its kinetic energy by collisional cooling. Recently new positron-positronium converters based on oxidized nanochannels in silicon were found to be very promising because of the tunability of the nanochannel size, which allows to overcome the limits imposed to the Ps cooling by the quantum confinement. With these converters, Ps with temperatures as low as 150 K was detected in vacuum by a TOF apparatus. The Ps formation, quantum confinement, collisional cooling and emission into vacuum from nanochanneled silicon will be discussed in light of recent results. © Published under licence by IOP Publishing Ltd
Time of Flight system to investigate positronium cooling
A positronium Time of Flight (TOF) apparatus, conceived to work with continuous positron beams of intensity up to ∼10 6 positrons/s, was developed. The geometry of the TOF chamber and the acquisition chain are described in detail. The performances of the set up were preliminary tested with a laboratory positron beam of ∼5 × 10 3 positrons/s by measuring the Time of Flight of Ps emitted from oxidized nanochannels produced in a Si single crystal. A TOF spectrum of ∼10 4 events was collected in 9 days with a time resolution of 8 ns. The analysis of the TOF spectrum is discussed. This apparatus is going to be assembled at the intense positron source NEPOMUC at FRM-II reactor, where the measurement time of each spectrum will be reduced to less than 2 h, making this TOF system appropriate to investigate positronium emission after cooling in porous materials held at cryogenic temperature. © The Author(s) 2012
Gas transport and free volume study in polyethylene based epoxy membranes
The mechanism of gas diffusivity in amine modified epoxy membranes is studied in the frame of free volume properties. Epoxy membranes with two different crosslinking densities and composite with Graphene nanoplatelets were prepared by solvent casting method. The free volume parameters measured by Positron Annihilation Spectroscopy (PAS) show inverse correlation with crosslinking density of the samples. The gas permeability and diffusivity for CO2 have been studied by gas permeation measurements. The study reveals that the gas permeability and diffusivity change significantly as a function of crosslinking density, free volumes and structural relaxations of the molecular chains
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Positron bunching system for producing positronium clouds into vacuum
A magnetic transport line, a magnetic field terminator and a positron buncher were designed and built to focus low-energy positron pulses from a Surko-type accumulator on a porous target. The 25 electrodes buncher, which produces a parabolic potential, was designed to implant 5 ns positron bunches with a spot of 3 mm into a target held at cryogenic temperature. These pulses will be used to obtain cooled Ps clouds into vacuum for laser excitation in spectroscopy experiments. By using high-voltage fast switches and a proper mu-metal shield the requirement to form Ps in a free (magnetic and electric) field region was satisfied compatibly with the request of injecting positrons at energies of 5-9 keV. The optical design, the electrical circuitry of the buncher and the construction solutions of the whole apparatus will be presented and explained. © Published under licence by IOP Publishing Ltd
Depth profile porosity and micro-structure evolution studied by positron annihilation and Raman spectroscopy in SIOCH low-k films
HYDROGEN SORPTION KINETICS IN THE Nb: ROLE OF Nb CLUSTERING AND OPEN VOLUME DEFECTS FORMATION
- …