1,720,993 research outputs found
Usefulness of combined bedside lung ultrasound and echocardiography to assess weaning failure from mechanical ventilation: a suggestive case*.
Objective: Recognition of the cardiac origin of weaning failure is a crucial issue for successful discontinuation of mechanical ventilation. Bedside lung ultrasound and echocardiography have shown a potential in predicting weaning failure. Objective of this report was to describe the case of a patient repeatedly failing to wean from mechanical ventilation, where the combined use of lung ultrasound and echocardiography during a spontaneous breathing trial uncovered an unexpected cause of the failure. Design: Case report. Setting: General ICU of a university teaching hospital. Patients: Single case, abdominal surgery postoperative patient, not predicted to experience a difficult weaning. Interventions: Cardiovascular therapy adjustments consistent with lung ultrasound and echocardiography findings acquired during spontaneous breathing trials. Measurements and Main Results: All patient's standard hemodynamic and respiratory parameters, datasets from comprehensive lung ultrasound and echocardiographic examinations, and pertinent data from biochemistry exams, were collected during two spontaneous breathing trials. Data from beginning and end of each of the two ultrasound monitored weaning trials, and from the end of the successful weaning trial following therapy and the previously failed one, were analyzed and qualitatively compared. Lung ultrasound performed at the end of the failed spontaneous breathing trial showed a pattern consistent with increased extravascular lung water (diffuse, bilateral, symmetrical, homogeneous sonographic interstitial syndrome). Concurrent echocardiography diagnosed left ventricular diastolic failure. Ultrasound findings at the end of the successful weaning trial showed normalization of the lung pattern and improvement of the echocardiographic one. The atient eventually returned to spontaneous respiration and was discharged from the ICU. Conclusions: The use of bedside lung ultrasound and echocardiography disclosed left ventricular diastolic dysfunction as unexpected cardiogenic cause of weaning failure and lead to subsequent correct patient management
Combined ultrasound–CT approach to monitor acute exacerbation of interstitial lung disease
Background: Lung ultrasound is a bedside non-irradiating tool for assessment and monitoring of lung diseases. A lung ultrasound score based on visualized artefacts allows reliable quantification of lung aeration, and is useful to monitor mechanical ventilation setting, fluid resuscitation and antibiotic response in critical care. In the context of interstitial lung diseases associated to connective tissue disorders, lung ultrasound has been integrated to computed tomography for diagnosis and follow-up monitoring of chronic lung disease progression. Case presentation: This case describes a severe acute exacerbation of interstitial lung disease associated to dermatomyositis–polymyositis requiring prolonged extra-corporeal life support. Lung ultrasound score was performed daily and allowed monitoring and guiding both the need of advanced imaging as computed tomography and immunosuppressive therapy. Conclusions: This case suggests lung ultrasound may be a useful monitoring tool for the response to immunosuppressive therapy in acute severe rheumatic interstitial lung disease, where chest X-ray is poorly informative, and transportation is at high risk
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Lung Ultrasound for Daily Monitoring and Management of ARDS Patients
Lung ultrasound has greatly developed in the last decade, becoming increasingly important both for the diagnosis and for the monitoring of acute respiratory failure; it can be used on a daily basis at the bedside to improve the clinical assessment of the critically ill. This review describes how lung ultrasound can be used to assess patients with acute respiratory distress syndrome (ARDS), from the initial diagnosis to the daily management and monitoring. Quantification of lung aeration can be performed at the bedside with the lung ultrasound score; it is reliable when compared with computed tomography scan, easy to learn, and repeatable. It can be used to guide mechanical ventilation, to identify positive end-expiratory pressure responders, and to assess the efficacy of recruitment maneuvers or pronation. It can be used to monitor recovery from the respiratory disorder and to detect an increase in extravascular lung water during fluid resuscitation. Alone or combined with other ultrasound techniques, lung ultrasound can help in the weaning process. Moreover, frequent ARDS complications such as pneumothorax and ventilator-associated pneumonia can be detected by ultrasound, which also serves as a guide to procedures such as fiberoptic bronchoscopy and pleural drainage. Thanks to its many clinical applications, lung ultrasound may in the future become part of the standard approach to patients with ARDS
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
- …